Related papers: A Luminosity Spectrometer for the Zeus Experiment …
The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same time the luminosity-measuring system of the ZEUS experiment…
The upgrade of the HERA accelerator has provided much increased collider luminosity. In turn, the improvements have necessitated a new design for the ZEUS luminosity measurements. The intense synchrotron radiation field, as well as the high…
A precise measurement of the spectrum of the photons from $ep$ bremsstrahlung with the ZEUS luminosity monitor at HERA is reported. The measurement shows a reduced rate compared to the Bethe-Heitler spectrum for photon energies below 5~GeV.…
The process pe -> pe+gamma with the photon emitted along the electron beam axis is used for luminosity measurement at HERA. In this paper the process is calculated including one-loop QED radiative corrections. In the ZEUS experiment, both…
A measurement of the longitudinal polarization of the electron beam at HERA utilizing coherent interactions of high energy photons in crystals is proposed. Modification of existing facilities would allow an independent polarization…
A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in…
A measurement of the integrated luminosity at the ep collider HERA is presented, exploiting the elastic QED Compton process ep \rightarrow ep. The electron and the photon are detected in the backward calorimeter of the H1 experiment. The…
The latest results from the ep HERA collider both within the Standard (electroweak) Model and beyond are reviewed. Most of the results are based on the full HERA data sample, which corresponds to an integrated luminosity of about 0.5 fb-1…
First inclusive measurements of isolated prompt photons in photoproduction at the HERA ep collider have been made with the ZEUS detector, using an integrated luminosity of 38.4 pb$^{-1}$. Cross sections are given as a function of the…
Direct detection of bremsstrahlung photons, in principle, offers the most straightforward and most robust method of luminosity determination at the EIC, but requires an extraordinary performance of the photon detector. In this paper, we…
The PEP-N experiment requires a fast on-line luminosity monitor of modest accuracy plus an off-line method of determining integrated luminosity with accuracy of 0.01 for each pb$^{-1}$. We propose the PEP-2 monitor, based on observing…
Recent results on spectroscopy and the measurement of hadronic final states in ep collisions from the H1 and ZEUS collaborations are presented using data sets with an integrated luminosity between 44 and 121 pb^-1 collected during the HERA…
The H1 detector at HERA has been upgraded by the addition of a new electromagnetic calorimeter. This is installed in the HERA tunnel close to the electron beam line at a position 8m from the interaction point in the electron beam direction.…
Charged multiplicity distributions and the mean charged multiplicity have been investigated in inclusive neutral current deep inelastic ep scattering with the ZEUS detector at HERA using an integrated luminosity of 38.6 pb-1. The…
The beam-helicity asymmetry in exclusive electroproduction of real photons by the longitudinally polarized HERA positron beam scattering off an unpolarized hydrogen target is measured at HERMES. The asymmetry arises from deeply virtual…
Selected aspects of photoproduction in ep scattering at the HERA collider, studied with the ZEUS detector, are presented. The results are interpreted in the formalism of Vector Dominance Model, Regge theory and perturbative Quantum…
The luminosity of the electron-proton collider, HERA, will be increased by a factor of five during the long shutdown in the year 2000. At the same time longitudinal lepton beam polarisation will be provided for the collider experiments H1…
The analysis of events containing multiple high Pt leptons (electrons and muons) produced in ep collisions has been performed with the H1 and ZEUS detectors at HERA, using the full data sets collected by the experiments in the period…
A new method is employed to measure the neutral current cross section up to Bjorken-x values of one with the ZEUS detector at HERA using an integrated luminosity of 65.1 pb-1 for e+p collisions and 16.7 pb-1 for e-p collisions at…
The ZEUS detector at HERA has been used to measure the photoproduction of isolated photons in diffractive events. Cross sections are evaluated in the photon transverse-energy and pseudorapidity ranges 5 < E_T^gamma < 15 Gev and -0.7 <…