Related papers: A Prototype RICH Detector Using Multi-Anode Photo …
We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes.…
The 64-channel Multianode Photo Multiplier (MaPMT) has been evaluated as a candidate for the LHCb Ring Imaging Cherenkov (RICH) photo detectors. We present result from data taken with a 3x3 array of closely packed MaPMTs mounted onto the…
Using aerogel as radiator and multianode PMTs for photon detection, a proximity focusing Cherenkov ring imaging detector has been constructed and tested in the KEK $\pi$2 beam. The aim is to experimentally study the basic parameters such as…
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for…
The RICH detectors of the LHCb experiment provide identification of hadrons produced in high energy proton-proton collisions in the LHC at CERN over a wide momentum range (2 to 100 GeV/c). Cherenkov light is collected on photon detector…
The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout…
Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must…
The limitations in performance of the present RICH system in the LHCb experiment are given by the natural chromatic dispersion of the gaseous Cherenkov radiator, the aberrations of the optical system and the pixel size of the photon…
We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel…
We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the…
We have built a RICH detector prototype consisting of a liquid C6F14 radiator and six triple Thick Gaseous Electron Multipliers (TGEMs), each of them having an active area of 10x10 cm2. One triple TGEM has been placed behind the liquid…
The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a…
We describe the particle identification capability of the CLEO RICH system. This system consists of a 1 cm thick LiF radiator coupled to a photon detector that uses wire proportional chambers filled with a mixture of CH$_4$ and TEA. We…
The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator…
A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index…
The construction and use of a dual radiator Ring Imaging Cerenkov(RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasizes measurements of semi-inclusive deep-inelastic scattering. It…
The 64-channel Multianode Photo Multiplier has been evaluated as a possible choice for the photo detectors of the LHCb Ring Imaging Cherenkov detector.
The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH$_4$ and TEA gases. The first two photon detector modules which were…
An algorithm for identifying rings in Ring Imaging Cherenkov (RICH) detectors is described. The algorithm is necessarily Bayesian and makes use of a Metropolis-Hastings Markov chain Monte Carlo sampler to locate the rings. In particular,…
CLEO III upgrade was completed with the integration of Ring Imaging CHerenkov(RICH) detector for charged particle identification. The design of this cylindrical detector consists of LiF crystal radiators and multi-wire proportional chamber…