Related papers: Thermoelastic-damping noise from sapphire mirrors …
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main…
Mirror thermal noise is and will remain one of the main limitations to the sensitivity of gravitational wave detectors based on laser interferometers. We report about projected mirror thermal noise due to losses in the mirror coatings and…
An analysis is given of thermoelastic noise (thermal noise due to thermoelastic dissipation) in finite sized test masses of laser interferometer gravitational-wave detectors. Finite-size effects increase the thermoelastic noise by a modest…
Increasing requirements in the sensitivity of interferometric measurements is a common feature of several research fields, from gravitational wave detection to quantum optics. This motivates refined studies of high reflectivity mirrors and…
In the baseline design for advanced LIGO interferometers, the most serious noise source is tiny, dynamically fluctuating bumps and valleys on the faces of the arm-cavity mirrors, caused by random flow of heat in the mirrors' sapphire…
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW…
We have measured the photothermal effect in a single cross-polarized interferometer at audio frequencies (5 Hz - 4 kHz). In a Fabry-Perot interferometer, light in one polarization is chopped to periodically heat the interferometer mirrors,…
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for…
We study theoretically the internal thermal noise of a mirror coated on a plano-convex substrate. The comparison with a cylindrical mirror of the same mass shows that the effect on a light beam can be reduced by a factor 10, improving the…
The intrinsic thermal noise in optical fibers is the ultimate limit of fiber-based systems. However, at infrasonic frequencies, the spectral behavior of the intrinsic thermal noise remains unclear so far. We present the measurements of the…
The displacement noise in the test mass mirrors of interferometric gravitational wave detectors is proportional to their elastic dissipation at the observation frequencies. In this paper, we analyze one fundamental source of dissipation in…
Thermally induced fluctuations impose a fundamental limit on precision measurement. In optical interferometry, the current bounds of stability and sensitivity are dictated by the excess mechanical damping of the high-reflectivity coatings…
Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of…
A standard quarter-wavelength multilayer optical coating will produce the highest reflectivity for a given number of coating layers, but in general it will not yield the lowest thermal noise for a prescribed reflectivity. Coatings with the…
We describe an experiment in which we have used a cold damping feedback mechanism to reduce the thermal noise of a mirror around its mechanical resonance frequency. The monitoring of the brownian motion of the mirror allows to apply an…
A fundamental limit to the sensitivity of optical interferometers is imposed by Brownian thermal fluctuations of the mirrors' surfaces. This thermal noise can be reduced by using larger beams which "average out" the random fluctuations of…
Suitable shaping (in particular, flattening and broadening) of the laser beam has recently been proposed as an effective device to reduce internal (mirror) thermal noise in advanced gravitational wave interferometric detectors. Based on…
Thermoelastic noise will be the most significant noise source in advanced-LIGO interferometers with sapphire test masses. The standard plan for advanced-LIGO has optimized the optics, within the framework of conventional mirrors, to reduce…
Thermoelastic loss is an important energy dissipation mechanisms in resonant systems. A careful analysis of the thermoelastic loss is critical to the design of low-noise devices for high-precision applications, such as the mirrors used for…
We present a concept of a mirror for the application in high-reflectivity low-noise instruments such as interferometers. The concept is based on an etalon with a metasurface (meta-etalon) on the front and a conventional multilayer stack on…