English
Related papers

Related papers: A low-temperature dynamic mode scanning force micr…

200 papers

A dual-excitation method for resonant-frequency tracking in scanning probe microscopy based on amplitude detection is developed. This method allows the cantilever to be operated at or near resonance for techniques where standard phase…

Materials Science · Physics 2008-03-13 B J Rodriguez , C Callahan , S V Kalinin , R Proksch

We have developed low temperature part of an ultra high vacuum scanning probe microscope (UHV-SPM) working at variable temperature within the range from 20 K to 700 K. To achieve the required temperature range, a flow cooling system using…

Instrumentation and Detectors · Physics 2016-10-04 Jiri Frolec , Jakub Vonka , Pavel Hanzelka , Tomas Kralik , Vera Musilova , Pavel Urban

Solid-state qubit manipulation and read-out fidelities are reaching fault-tolerance, but quantum error correction requires millions of physical qubits and thus a scalable quantum computer architecture. To solve signal-line bandwidth and…

In the last decade, detecting spin dynamics at the atomic scale has been enabled by combining techniques like electron spin resonance (ESR) or pump-probe spectroscopy with scanning tunneling microscopy (STM). Here, we demonstrate an…

We present the construction and performance of an ultra-low temperature scanning tunneling microscope (STM), working in ultra-high vacuum conditions (UHV) and in high magnetic fields up to 9 T. The cryogenic environment of the STM is…

Strongly Correlated Electrons · Physics 2018-06-12 C. Salazar , D. Baumann , T. Hänke , M. Scheffler , T. Kühne , M. Kaiser , R. Voigtländer , D. Lindackers , B. Büchner , C. Hess

Electrostatic force microscopy at cryogenic temperatures is used to probe the electrostatic interaction of a conductive atomic force microscopy tip and electronic charges trapped in localized states in an insulating layer on a…

Materials Science · Physics 2009-11-10 Aykutlu Dana , Yoshihisa Yamamoto

In this study the magnetic order of the spin-1/2 XXZ chain system Cs$_2$CoCl$_4$ in a temperature range from 50 mK to 0.5 K and in applied magnetic fields up to 3.5 T is investigated by high-resolution measurements of the thermal expansion…

Strongly Correlated Electrons · Physics 2015-03-13 O. Breunig , M. Garst , A. Rosch , E. Sela , B. Buldmann , P. Becker , L. Bohaty , R. Müller , T. Lorenz

Ferroelectric domain walls have emerged as one of the most fascinating objects in condensed matter physics due to the broad variability of functional behaviors they exhibit. However, the vast majority of domain walls studies have been…

The development and characterisation of a piezoelectric actuated high-frequency MEMS scanning mirror with on-chip frequency tuning capability is reported. The resonant scanner operates at frequencies in excess of 140 kHz, generating scan…

Applied Physics · Physics 2022-06-15 Paul Janin , Deepak Uttamchandani , Ralf Bauer

If confocal microscopy is an ubiquitous tool in life science, its applications in chemistry and materials science are still, in comparison, very limited. Of particular interest in these domains is the use of confocal microscopy to…

Soft Condensed Matter · Physics 2017-12-25 Dmytro Dedovets , Cécile Monteux , Sylvain Deville

Phase coexistence across disorder-broadened and magnetic-field-induced first order antiferromagnetic to ferrimagnetic transition in polycrystalline $Mn_{1.85}Co_{0.15}Sb$ has been studied mesoscopically by Scanning Hall Probe Microscope at…

Strongly Correlated Electrons · Physics 2009-11-13 Pallavi Kushwaha , Archana Lakhani , R Rawat , A Banerjee , P Chaddah

In this paper, we have designed a low-cost scanning tunneling microscope (STM) priced at 300 USD or 2000 CNY. This microscope is suitable for educational purposes and low-demand research imaging at the nanometer level. This microscope's…

Instrumentation and Detectors · Physics 2024-01-17 Weilin Ma

The dynamics of spin-boson systems at very low temperatures has been studied using a real-time path-integral simulation technique which combines a stochastic Monte Carlo sampling over the quantum fluctuations with an exact treatment of the…

chem-ph · Physics 2009-10-22 Reinhold Egger , C. H. Mak

We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of…

Mesoscale and Nanoscale Physics · Physics 2015-06-17 A. Roychowdhury , M. A. Gubrud , R. Dana , J. R. Anderson , C. J. Lobb , F. C. Wellstood , M. Dreyer

A cryo scanning transmission X-ray microscope, the cryo-STXM, has been designed and commissioned at the Canadian Light Source synchrotron. The instrument is designed to operate from 100 - 4000 eV (lambda = 12.4 - 0.31 nm). Users can insert…

Next-generation centimeter to sub-millimeter telescopes require exquisite control over instrumental far-sidelobe response to accurately measure faint signals like the Cosmic Microwave Background B modes. Because existing electromagnetic…

Instrumentation and Methods for Astrophysics · Physics 2025-12-24 Oliver Jeong , Jacques Delabrouille , Michel Piat

We report on the development of an induction based low temperature high frequency ac susceptometer capable of measuring at frequencies up to 3.5 MHz and at temperatures between 2 K and 300 K. Careful balancing of the detection coils and…

Instrumentation and Detectors · Physics 2019-09-04 E. Riordan , J. Blomgren , C. Jonasson , F. Ahrentorp , C. Johansson , D. Margineda , A. Elfassi , S. Michel , F. Dell'ova , G. M. Klemencic , S. R. Giblin

By scanning a fine open-ended coaxial probe above an operating microwave device, we image local electric fields generated by the device at microwave frequencies. The probe is sensitive to the electric flux normal to the face of its center…

We demonstrate the measurement and manipulation of the temperature of cold CO molecules in a microchip environment. Through the use of time-resolved spatial imaging, we are able to observe the phase-space distribution of the molecules, and…

We have performed scanning capacitance microscopy using a relaxation oscillator. Precision calibrations indicate a sensitivity on the order of 0.05 pF. Surface topography of metallic structures, such as machined grooves and coins, can be…

Materials Science · Physics 2015-06-18 Marie Pahlmeyer , Andrew Hankins , Sam Tuppan , Woo-Joong Kim