English
Related papers

Related papers: A versatile and compact capacitive dilatometer

200 papers

We report on the development of a capacitance measuring system which allows measurements of capacitance in pulsed magnetic fields up to 61~T. By using this system, magnetic-field responses of various physical quantities such…

The resonant frequencies of three-dimensional microwave cavities are explicitly dependent on the dielectric constant of the material filling the cavity, making them an ideal system for probing material properties. In particular, dielectric…

Other Condensed Matter · Physics 2022-12-21 R. T. Learn , E. Varga , V. Vadakkumbatt , J. P. Davis

Major challenges of micro thermal machines are the thermal insulation and mechanical tolerance in the case of sliding piston. Switching from piston to membrane in microengines can alleviate the latest and lead to planar architectures.…

Classical Physics · Physics 2013-01-22 Fabien Formosa , Adrien Badel , Hugues Favrelière

In this laboratory-based study, a plate was designed, manufactured and then characterised thermally and dimensionally using a thermal imager. This plate comprised a range of known scratch, dent, thinning and pitting artefacts as mimics of…

Time-domain thermoreflectance (TDTR) is a powerful technique for characterizing the thermal properties of layered materials. However, its effectiveness at modulation frequencies below 0.1 MHz is hindered by pulse accumulation effects,…

We have measured the thermal conductivity of glassy glycerol between 1.5 K and 100 K, as well as the specific heat of both glassy and crystalline phases of glycerol between 0.5 K and 25 K. We discuss both low-temperature properties of this…

Disordered Systems and Neural Networks · Physics 2009-11-07 C. Talon , Q. W. Zou , M. A. Ramos , R. Villar , S. Vieira

Refractive optics in astronomical instruments are potentially sensitive to temperature gradients and temperature transients. This sensitivity arises from thermally dependent refractive indices, lens spacings, and lens dimensions. We have…

Astrophysics · Physics 2014-10-13 Warren R. Brown , Daniel G. Fabricant , David A. Boyd

We developed a new type of AC microcalorimeter based on a modulated-bath technique for measuring the specific heat of small microgram samples in the temperature range from 30-300 K, and tested it in magnetic fields up to 14 T. The device is…

Other Condensed Matter · Physics 2015-06-25 Rolf Lortz , Satoko Abe , Yuxing Wang , Frederic Bouquet , Ulrich Tutsch , Alain Junod

We have developed a new calorimeter for measuring thermodynamic properties in pulsed magnetic fields. An instrumental design is described along with the construction details including the sensitivity of a RuO2 thermometer. The operation of…

Instrumentation and Detectors · Physics 2021-04-14 Shusaku Imajo , Chao Dong , Akira Matsuo , Koichi Kindo , Yoshimitsu Kohama

We describe a low-cost and simple setup for hyperthermia measurements on colloidal solutions of magnetic nanoparticles (ferrofluids) with a frequency-adjustable magnetic field in the range 5-500 kHz produced by an electromagnet. By…

Materials Science · Physics 2008-10-09 L. -M. Lacroix , J. Carrey , M. Respaud

The fundamental properties of ice have always attracted a lot of interest due to omnipresence of ice in many different natural contexts. Since cubic ice recently become experimentally accessible from a low-density gas hydrate precursor [1,…

We describe the construction and operation of an external cavity diode laser in which the diode is cooled to -45 C. This technique allows us to pull the wavelength of a nominally 782 nm diode to operate at 766.7 nm, a change of over 15 nm.…

Condensed Matter · Physics 2009-11-10 C. S. Fletcher , J. D. Close

Levitated oscillators with millimeter or sub-millimeter size are particularly attractive due to their potential role in studying various fundamental problems and practical applications. One of the crucial issues towards these goals is to…

Quantum Physics · Physics 2021-07-21 Fang Xiong , Peiran Yin , Tong Wu , Han Xie , Rui Li , Yingchun Leng , Yanan Li , Changkui Duan , Xi Kong , Pu Huang , Jiangfeng Du

We demonstrate a scheme for realizing a compact cold atom gravimeter. The use of a hollow pyramidal configuration allows to achieve all functions: trapping, interferometer and detection with a unique laser beam leading to a drastic…

Broadband seismometers are widely used in global observation networks deployed for geophysics research. Recently, the calibration of their sensitivity has become an important factor for ensuring observation accuracy. One of the limiting…

Geophysics · Physics 2026-03-03 Tomofumi Shimoda , Wataru Kokuyama , Hideaki Nozato

We report on the fabrication of sensitive nanotorsional resonators, which can be utilized as magnetometers for investigating the magnetization dynamics in small magnetic elements. The thermo-mechanical noise is calibrated with the resonator…

Mesoscale and Nanoscale Physics · Physics 2012-03-06 Joseph Losby , Jacob A. J. Burgess , Zhu Diao , David C. Fortin , Wayne K. Hiebert , Mark R. Freeman

High-resolution synchrotron x-ray diffraction measurements were performed on single crystalline and powder samples of BiMn2O5. A linear temperature dependence of the unit cell volume was found between T_{N}=38$ K and 100 K, suggesting that…

Materials Science · Physics 2009-11-13 E. Granado , M. S. Eleoterio , A. F. Garcia-Flores , J. A. Souza , E. I. Golovenchits , V. A. Sanina

A flat mounting unit with electronically variable thermal resistance [1] has been presented in the last year [2]. The design was based on a Peltier cell and the appropriate control electronics and software. The device is devoted especially…

General Physics · Physics 2008-01-08 V. Szekely , S. Torok , E. Kollar

We present a simple fabrication technique for lateral nanowire wrap-gate devices with high capacitive coupling and field-effect mobility. Our process uses e-beam lithography with a single resist-spinning step, and does not require chemical…

Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5…