Related papers: A Twisted Pair Cryogenic Filter
A shift of paradigm to obtain (sub-)Kelvin environment is currently on-going with the democratization of cryogen-free cryocoolers, boosted by their easy-to-use and continuous operation without the need of liquid helium whose cost and…
We experimentally demonstrate a method to determine the temperature of trapped ions which is suitable for monitoring fast thermalization processes. We show that observing and analyzing the lineshape of dark resonances in the fluorescence…
We present the required techniques for the successful low loss packaging of integrated photonic devices capable of operating down to 970 mK utilizing photonic wire bonds. This scalable technique is shown to have an insertion loss of less…
The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…
Large-scale cryogenic quantum systems are constrained by an input-output bottleneck between room-temperature electronics and millikelvin stages, particularly in superconducting qubit platforms. This bottleneck is most acute for output…
Encoding information onto optical fields is the backbone of modern telecommunication networks. Optical fibers offer low loss transport and vast bandwidth compared to electrical cables, and are currently also replacing coaxial cables for…
We present a cryogenic microwave noise source with a characteristic impedance of 50 $\Omega$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K…
Low-frequency qubit control wires require non-trivial thermal anchoring and low-pass filtering. The resulting electron temperature serves as a quality benchmark for these signal lines. In this technical note, we make use of a primary…
This paper presents an analysis of the conceptual design of a novel silicon suspension for the cryogenic test-mass mirrors of the low-frequency detector of the Einstein Telescope gravitational-wave observatory. In traditional suspensions,…
We present a study of thin-film molybdenum resistors for NbN electronics operating at cryogenic temperatures. The key step is the 0.5-1.5 keV ion cleaning-activation of NbN before Mo deposition which allows to obtain a high-quality Mo/NbN…
We report an accurate measurement of the phase noise of a thermally limited electronic oscillator at 300 K. By thermally limited we mean that the white signal-to-noise ratio of the oscillator is at or near the level generated by the thermal…
A new method based on negative thermal expansion material coating is proposed to realize temperature insensitive fiber coupler. By coating a layer of modified epoxy resin with a negative thermal expansion coefficient onto the coupling…
Cryogenic detectors are at the forefront of rare-event search experiments, including direct detection of dark matter, coherent elastic neutrino-nucleus scattering, neutrinoless double-beta decay, and searches for fractionally charged…
We propose and test a cryogenic setup comprising dielectric waveguides for mm-wave frequencies in the range of 75-110 GHz and temperatures down to 10 mK. The targeted applications are quantum technologies at millimeter-wave frequencies,…
Brillouin-Mandelstam scattering is a strong and readily accessible optical nonlinearity enabling a wide array of applications and research directions. For instance, the three-wave mixing process has been employed to great success for…
A biaxial tensile device for the transport study of layered materials is described. The device is mounted on the standard 24 pin zero force connector and can be moved between various setups. The compact design of the device makes it…
Continuing advancements in quantum information processing have caused a paradigm shift from research mainly focused on testing the reality of quantum mechanics to engineering qubit devices with numbers required for practical quantum…
A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…
Atomic-resolution cryogenic scanning transmission electron microscopy (cryo-STEM) has provided a path to probing the microscopic nature of select low-temperature phases in quantum materials. Expanding cryo-STEM techniques to broadly tunable…
Dense arrays of trapped ions provide one way of scaling up ion trap quantum information processing. However, miniaturization of ion traps is currently limited by sharply increasing motional state decoherence at sub-100 um ion-electrode…