English
Related papers

Related papers: Modulated-bath AC calorimetry using modified comme…

200 papers

We report specific heat measurements at magnetic fields up to 20 T on the recently discovered superconductor SmFeAsO$_{0.85}$F$_{0.15}$. The B-T diagram of a polycrystalline SmFeAsO$_{0.85}$F$_{0.15}$ sample with T$_c$ = 46 K was…

Superconductivity · Physics 2009-11-13 C. Senatore , M. Cantoni , G. Wu , R. H. Liu , X. H. Chen , R. Flukiger

A quantum-dot thermal transistor consisting of three Coulomb-coupled quantum dots coupled to respective electronic reservoirs by tunnel contacts is established. The heat flows through the collector and emitter can be controlled by the…

Applied Physics · Physics 2018-11-29 Yanchao Zhang , Zhimin Yang , Xin Zhang , Bihong Lin , Guoxing Lin , Jincan Chen

Increasing the luminosity of relativistic hadron beams is critical for the advancement of nuclear physics. Coherent electron cooling (CEC) promises to cool such beams significantly faster than alternative methods. We present simulations of…

We present a specific heat measurement technique adapted to thin or very thin suspended membranes from low temperature (8 K) to 300 K. The presented device allows the measurement of the heat capacity of a 70 ng silicon nitride membrane (50…

Mesoscale and Nanoscale Physics · Physics 2015-12-02 Hossein Ftouni , Dimitri Tainoff , Jacques Richard , Kunal Lulla , Jean Guidi , Eddy Collin , Olivier Bourgeois

Room-level air conditioners (also referred as ACs) consume a significant proportion of total energy in residential and small-scale commercial buildings. In a typical AC, occupants specify their comfort requirements by manually setting the…

Human-Computer Interaction · Computer Science 2018-05-17 Milan Jain

For modern Gas sensors, high sensitivity and low power are expected. This paper discusses design, simulation and fabrication of new Micromachined Thermal Converters (MTCs) based on GaAs developed for Gas sensors. Metal oxide gas sensors…

Other Computer Science · Computer Science 2008-02-22 J. Jakovenko , M. Husak , T. Lalinskytfh , M. Drzik , G. Vanko

We present ultra-thin silicon membrane thermocouple bolometers suitable for fast and sensitive detection of low levels of thermal power and infrared radiation at room temperature. The devices are based on 40 nm-thick strain tuned single…

We describe a new 17 T cryomagnet for neutron, x-ray or optical experiments with rapid in-situ sample change. Sample temperatures are controllable from < 2 K to 300 K in vacuum. Alternatively a room temperature bore insert can be used for…

The cooling of boiling water all the way down to freezing, by thermally connecting it to a thermal bath held at ambient temperature without external intervention, would be quite unexpected. We describe the equivalent of a 'thermal…

Statistical Mechanics · Physics 2019-04-22 Andreas Schilling , Xiaofu Zhang , Olaf Bossen

Gas behavior in systems at microscale has been receiving significant attention from researchers in the last two decades [1-4]. Today, there is an enhanced emphasis on developing new experimental techniques to capture the local temperature…

Instrumentation and Detectors · Physics 2019-08-05 Varun Yeachana , Vikash Kumar , Lucien Baldas , Marcos Rojas-Cárdenas , Christine Barrot , Ryan Enright , Stéphane Colin

Temperature coefficient of resistance (TCR) of a bolometer can be tuned by modifying the thermal conductance of an absorbing materials since they sense radiations via the temperature change in the absorber. However, the thermal conductance…

Applied Physics · Physics 2024-06-13 Saba M. Khan , Jyoti Saini , Anirban Kundu , Renu Rani , Kiran S. Hazra

We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature…

Fluid Dynamics · Physics 2023-11-01 Xinyang Ge , Joanna A. Zielińska , Sergio Maldonado

The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating…

Instrumentation and Detectors · Physics 2022-07-20 E. Garutti , R. Klanner , E. Popova , S. Martens , J. Schwandt , C. Villalba

The complex electric modulus and the ac conductivity of carbon nanoonion/polyaniline composites were studied from 1 mHz to 1 MHz at isothermal conditions ranging from 15 K to room temperature. The temperature dependence of the electric…

Type I superconductivity has recently been reported for the Dirac semimetal PdTe$_2$ (Tc approximately 1.6K) with, remarkably, multiple critical fields and a complex phase diagram. Here, measurements of the specific heat utilizing a thermal…

Superconductivity · Physics 2021-03-10 M. V. Salis , Y. K. Huang , A. de Visser

We have measured the specific heat of the coupled spin-dimer antiferromagnet Ba$_3$Mn$_2$O$_8$ to 50 mK in temperature and to 29 T in the magnetic field. The experiment extends to the midpoint of the field region (25.9 T $\leq H \leq$ 32.3…

Strongly Correlated Electrons · Physics 2009-11-11 H. Tsujii , B. Andraka , M. Uchida , H. Tanaka , Y. Takano

Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as…

Instrumentation and Detectors · Physics 2008-11-26 E. Frlez , M. Bychkov , D. Pocanic

Manipulating bosonic condensates with electric fields is very challenging as the electric fields do not directly interact with the neutral particles of the condensate. Here we demonstrate a simple electric method to tune the vorticity of…

The temperature of the working environment is a key factor in determining the properties of semiconductor detectors, and it affects the absolute accuracy and stability of the standard detector. In order to determine the temperature…

Instrumentation and Detectors · Physics 2016-11-22 Si-Ming Guo , Jin-Jie Wu , Jian Zhang , Xu-Fang Li , Cong-Zhan Liu , Shuai Zhang , Cheng-Ze Li , Bin-Bin Huo , Zhen-Yu Liao

Thermal convection based micro-electromechanical accelerometer is a relatively new kind of acceleration sensor that does not require a solid proof mass, yielding unique benefits like high shock survival rating, low production cost, and…

Applied Physics · Physics 2018-01-24 Rahul Mukherjee , Joydeep Basu , Pradip Mandal , Prasanta Kumar Guha