Related papers: 320-Channel Dual Phase Lock-in Optical Spectromete…
We present a rapid-scanning approach to fluorescence-detected two-dimensional electronic spectroscopy that combines acousto-optic phase-modulation with digital lock-in detection. The approach shifts the signal detection window to suppress…
A novel method of spectroscopy in ion traps termed leak-out spectroscopy (LOS) is presented. Here, mass selected, cold ions are excited by an infrared laser. In a subsequent collision with a neutral buffer gas particle their internal energy…
Non-line-of-sight (NLOS) imaging relies on collecting light that is rendered incoherent from the multiple scattering events and is then post-processed to provide an estimate of the hidden scene. Here we employ coherent phase control of the…
Coherent dual-comb spectroscopy (DCS) enables high-resolution measurements at high speeds without the trade-off between resolution and update rate inherent to mechanical delay scanning approaches. However, high system complexity and limited…
In Broadband Stimulated Raman Spectroscopy, the intrinsic limit given by the laser shot noise is seldom reached due to the electronic noise of the front-end amplifier and the intensity fluctuations of the laser source. In this paper we…
For the first time, a CAOS (i.e., Coded Access Optical Sensor) spectrometer is demonstrated. The design implemented uses a reflective diffraction grating and a time-frequency CAOS mode operations Digital Micromirror Device (DMD) in…
We describe an experiment to measure the emitted real-time electric field from an ultrafast third-order nonlinear optical interaction in molecules, using a phase-tracked spectral interferometry scheme. By combining a software lock-in…
Conventional spectrometer and polarimeter systems rely on bulky optics, fundamentally limiting compact integration and hindering multi-dimensional optical sensing capabilities. Here, we propose a spectropolarimeter enabled by…
In the first part of the paper, a CAOS line camera is introduced for spectral imaging of one dimensional (1-D) or line targets. The proposed spectral camera uses both a diffraction grating as well as a cylindrical lens optics system to…
We demonstrate a lock-in particle tracking scheme in optical tweezers based on stroboscopic modulation of an illuminating optical field. This scheme is found to evade low frequency noise sources while otherwise producing an equivalent…
We demonstrate an approach to two-dimensional electronic spectroscopy (2DES) that combines the benefits of shot-to-shot detection at high-repetition rates with the simplicity of a broadband white light continuum input and conventional…
Temperature drift, stress birefringence and low frequency vibration lead to the randomness and fluctuation of the output of optical voltage sensor(OVS). In order to solve the problem, this study adopts the lock-in amplifier technology with…
Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for…
Programmable spatiotemporal control of light is crucial for advancements in optical communications, imaging, and quantum technologies. Commercial spatial light modulators (SLMs) typically have megapixel-scale apertures but are limited to…
In the Kaos spectrometer at the Mainz Microtron a high-resolution coordinate detector for high-energy particles is operated. It consists of scintillating fibres with diameters of < 1mm and is read out by > 4000 multi-anode photomultiplier…
In atomic and molecular phase measurements using laser-induced fluorescence detection, optical cycling can enhance the effective photon detection efficiency and hence improve sensitivity. We show that detecting many photons per atom or…
[ABRIDGED] AIMS. MONOS is collecting information and studying O-type spectroscopic binaries with delta > -20 deg. In this 1st paper we describe the sample and provide spectral classifications and additional information for objects with…
Optical two-dimensional coherent spectroscopy (2DCS) is a powerful ultrafast spectroscopic technique that can greatly benefit from the unique features of a femtosecond laser operating at a kHz repetition rate. However, isolating specific…
Ultrabroadband electro-optic sampling with few-cycle optical pulses is known to be an extremely sensitive technique to detect electric field amplitudes. By combining this method with dual-comb spectroscopy and with a new class of ultrafast…
Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via…