Related papers: The activated torsion oscillation magnetometer
We present a mechanical cantilever-based tabletop interferometer to measure the radiation force exerted by light. Using a high-power (~ 1W) pulsed laser beam, we excite mechanical oscillations in a thin metallic cantilever. The cantilever…
We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…
We present a micro-mechanical terahertz (THz) detector fabricated on a silicon on insulator (SOI) substrate and operating at room-temperature. The device is based on a U-shaped cantilever of micrometric size, on top of which two aluminum…
Noise measurements have been carried out in the LISA bandwidth (0.1 mHz to 100 mHz) to characterize an all-optical atomic magnetometer based on nonlinear magneto-optical rotation. This was done in order to assess if the technology can be…
We present the coupled oscillator: a new mechanism for signal amplification with widespread application in metrology. We introduce the mechanical theory of this framework, and support it by way of simulations. We present a particular…
Optomechanical systems offer one of the most sensitive methods for detecting mechanical motion using shifts in the optical resonance frequency of the optomechanical resonator . Presently, these systems are used for measuring mechanical…
We present a probe-type scanning tunneling microscope (STM) with atomic resolution that is designed to be directly inserted and work in a harsh vibrational cryogen-free superconducting magnet system. When a commercial variable temperature…
We demonstrate the imaging of ferromagnetic carbon steel samples and we detect the thinning of their profile with a sensitivity of 0.1 mm using a Cs radio-frequency atomic magnetometer. Images are obtained at room temperature, in…
Developing the isolation and control of ultracold atomic systems to the level of single quanta has led to significant advances in quantum sensing, yet demonstrating a quantum advantage in real world applications by harnessing entanglement…
Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The…
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells…
We describe an ultra-sensitive atomic magnetometer using optically-pumped potassium atoms operating in spin-exchange relaxation free (SERF) regime. We demonstrate magnetic field sensitivity of 160 aT/Hz$^{1/2}$ in a gradiometer arrangement…
We describe a new type of torsional oscillator, suitable for studies of quantum fluids at frequencies of $\sim$ $100$ Hz, but capable of reaching high velocities of up to several cm\,s$^{-1}$. This requires the oscillator amplitude to…
Tapping mode atomic force microscopy (AFM), also known as amplitude modulated (AM) or AC mode, is a proven, reliable and gentle imaging mode with widespread applications. Over the several decades that tapping mode has been in use,…
Surface based geometries of microfabricated wires or patterned magnetic films can be used to magnetically trap and manipulate ultracold neutral atoms or Bose-Einstein condensates. We investigate the magnetic properties of such atom chips…
The three axis magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric…
Detection and imaging of an electrically conductive object at a distance can be achieved by inducing eddy currents in it and measuring the associated magnetic field. We have detected low-conductivity objects with an optical magnetometer…
A DC non-contact method for measuring the magnetostrictive strain in thin-films is demonstrated, achieving a state-of-the-art sensitivity of 0.1 ppm. In this method, an optical profilometer is used to measure the curvature induced in a…
The advent of milli-kelvin scanning tunneling microscopes (STM) with inbuilt magnetic fields has opened access to the study of magnetic phenomena with atomic resolution at surfaces. In the case of single atoms adsorbed on a surface, the…
Compared to light interferometers, the flux in cold-atom interferometers is low and the associated shot noise large. Sensitivities beyond these limitations require the preparation of entangled atoms in different momentum modes. Here, we…