English
Related papers

Related papers: Peltier ac calorimeter

200 papers

Thermoelectric effects allow the generation of electrical power from waste heat and the electrical control of cooling and heating. Remarkably, these effects are also highly sensitive to the asymmetry in the density of states around the…

Mesoscale and Nanoscale Physics · Physics 2016-07-13 I. J. Vera-Marun , J. J. van den Berg , F. K. Dejene , B. J. van Wees

A theoretical proposal that Coulomb-coupled quantum dots can be used as quantum probes to determine the temperature of a sample (i.e., an electronic reservoir) is proposed. Through the regulation of the positive or negative voltage bias in…

Mesoscale and Nanoscale Physics · Physics 2019-08-13 Yanchao Zhang , Jincan Chen

This paper presents dynamic thermal analyses of a power amplifier. All the investigations are based on the transient junction temperature measurements performed during the circuit cooling process. The presented results include the cooling…

Materials Science · Physics 2007-09-13 J. Banaszczyk , G. De Mey , M. Janicki , A. Napieralski , B. Vermeersch , P. Kawka

A new calorimeter for measurements of the AC heat capacity and magnetocaloric effect of small samples in pulsed magnetic fields is discussed for the exploration of thermal and thermodynamic properties at temperatures down to 2 K. We tested…

Materials Science · Physics 2010-10-20 Yoshimitsu Kohama , Christophe Marcenat , Thierry Klein , Marcelo Jaime

Heat dissipation is one of the most serious problems in modern integrated electronics with the continuously decreasing devices size. Large portion of the consumed power is inevitably dissipated in the form of waste heat which not only…

Applied Physics · Physics 2021-07-21 Xue Gong , Ruijie Qian , Huanyi Xue , Weikang Lu , Zhenghua An

Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward…

Instrumentation and Detectors · Physics 2021-03-09 L. Brunetti , L. Oberto , E. Vremera

Every time a chemical reaction occurs, an energy exchange between reactants and environment exists, which is defined as the enthalpy of the reaction. In the last decades, research has resulted in an increasing number of devices at the…

We have developed a calorimeter able to give a qualitative picture of the specific heat of a sample under high pressure up to approximately 10 GPa. The principle of ac-calorimetry was adapted to the conditions in a high pressure clamp. The…

Strongly Correlated Electrons · Physics 2009-10-31 F. Bouquet , Y. Wang , H. Wilhelm , D. Jaccard , A. Junod

The concept of "thermal inductance" expands the options of thermal circuit design. However, the inductive component is the only missing components in thermal circuits, unlike their electromagnetic counterparts. Herein, we report an…

Applied Physics · Physics 2026-05-08 Kenjiro Okawa , Yasutaka Amagai , Hiroyuki Fujiki , Nobu-Hisa Kaneko

Heat capacity measurements under high pressure places high demands on the calorimeter. Here we describe the development of a miniaturized nanocalorimeter for high-pressure heat capacity measurements at low temperature. The device,…

Instrumentation and Detectors · Physics 2025-01-30 Neha Kondedan , Andreas Rydh

In calorimetry and particularly in heat capacity measurements, different characteristic relaxation time constants may perturb the experiment which cannot be considered at thermodynamic equilibrium. In this case, thermodynamics of…

Other Condensed Matter · Physics 2007-06-29 Jean-Luc Garden , Jacques Richard

The simulation of the development of cascade processes in calorimeters of different types for the implementation of energy measurement by correlation curves method, is carried out. Heterogeneous calorimeter has a significant transient…

Instrumentation and Methods for Astrophysics · Physics 2014-11-04 E. A. Grushevskaya , I. A. Lebedev , A. I. Fedosimova

A new method of absolute heat capacity measurement was developed in the Department of Biological Systems Physics at the E. Andronikashvili Institute of Physics, Georgian Academy of Sciences. This is the method of absolute heat capacity…

Biological Physics · Physics 2007-05-23 G. Tvauri , N. Bakradze , E. Kiziria

We report on the resistance behavior of bare-chip Cernox thermometers under pressures up to 2 GPa, generated in a piston-cylinder pressure cell. Our results clearly show that Cernox thermometers, frequently used in low-temperature…

Materials Science · Physics 2019-02-21 Elena Gati , Gil Drachuck , Li Xiang , Lin-Lin Wang , Sergey L. Bud'ko , Paul C. Canfield

This work builds on the previous introduction [1] of a coupled experimental-computational system devised to fully characterize the thermal behavior of complex 3D submicron electronic devices. The new system replaces the laser-based surface…

Materials Science · Physics 2007-09-13 Peter E. Raad , Pavel L. Komarov , M. Burzo

The coupled transport of charge and heat provide fundamental insights into the microscopic thermodynamics and kinetics of materials. We describe a sensitive ac differential resistance bridge that enables measurements of the temperature…

Materials Science · Physics 2023-12-13 Zhe Cheng , Yu-Ju Huang , Beniamin Zahiri , Patrick Kwon , Paul V. Braun , David G. Cahill

A proximity-effect thermometer measures the temperature dependent critical supercurrent in a long superconductor - normal metal - superconductor (SNS) Josephson junction. Typically, the transition from the superconducting to the normal…

Superconductivity · Physics 2010-03-29 M. Meschke , J. T. Peltonen , H. Courtois , J. P. Pekola

The Peltier coefficient describes the amount of heat that is carried by an electrical current when it passes through a material. Connecting two materials with different Peltier coefficients causes a net heat flow towards or away from the…

Mesoscale and Nanoscale Physics · Physics 2012-04-02 J. Flipse , F. L. Bakker , A. Slachter , F. K. Dejene , B. J. van Wees

To achieve accurate results in nanocalorimetry a detailed analysis and understanding of the behavior of the calorimetric system is required. There are especially two system-related aspects that should be taken in consideration: the…

Other Condensed Matter · Physics 2012-03-12 S. Tagliati , A. Rydh

Chromatic calorimetry introduces a novel approach to calorimeter design in High Energy Physics (HEP) by integrating Quantum Dot (QD) technology into traditional homogeneous calorimeters. The tunable emission spectra of QDs provide new…

Instrumentation and Detectors · Physics 2025-07-23 Yacine Haddad , Devanshi Arora , Etiennette Auffray , Michael Doser , Matteo Salomoni , Michele Weber