Related papers: Bottom-loading dilution refrigerator with ultra-hi…
He-3/He-4 dilution refrigerators (DR) are very common in sub-Kelvin temperature research. We describe a pulse tube precooled DR where a separate He-4 circuit condenses the He-3 of the dilution loop. Whereas in our previous work the dilution…
We report on magnetron deposition of thin superconducting rhenium films on sapphire substrates. During the deposition, substrates were held at ambient temperature. Critical temperature of the films is Tc~3.6 K. Films have polycrystalline…
Next-generation gravitational wave observatories are expected to use cryogenically cooled, pendulum-suspended 200 kg test mass mirrors from a crystalline material such as crystalline silicon. During operation of the observatories, these…
We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3 but the setup allows…
In this article we summarize experimental work on cryogen-free 3He/4He dilution refrigerators which, in addition to the dilution refrigeration circuit, are equipped with a 4He-1K-stage. This type of DR becomes worth considering when high…
We demonstrate a novel atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any <100 um-thin, UHV-compatible material, while also allowing sample exchange with minimal…
Experiments performed at a temperature of a few millikelvin require effective thermalization schemes, low-pass filtering of the measurement lines and low-noise electronics. Here, we report on the modifications to a commercial dilution…
A sputter deposition source for use in ultrahigh vacuum (UHV) is described and some properties of the source are analyzed. The operating principle is based on the design developed by Mayr et al. [Rev. Sci. Instrum. 84, 094103 (2013)], where…
Cryogenic transmission electron microscopy has revolutionized structural biology and materials science, but achieving temperatures below the boiling point of liquid nitrogen remains a long-standing aspiration. We introduce an ultra-cold…
Cooling down nanomechanical force probes is a generic strategy to enhance their sensitivities through the concomitant reduction of their thermal noise and mechanical damping rates. However, heat conduction mechanisms become less efficient…
One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high…
Isotopically layered amorphous solid water films were used to measure the diffusivity of deeply supercooled liquid water near the glass transition. The films, composed of separate layers of oxygen 16 and oxygen 18 labeled water, were grown…
Temperature below 100 microKelvin is achieved in a customized cryogen-free dilution refrigerator with a copper-nuclear demagnetization stage. The lowest temperature of conduction electrons of the demagnetization stage is below 100…
We demonstrate successful "dry" refrigeration of quantum fluids down to $T=0.16$\,mK by using copper nuclear demagnetization stage that is pre-cooled by a pulse-tube-based dilution refrigerator. This type of refrigeration delivers a…
Improved accessibility to the microkelvin temperature regime is important for future research in quantum materials; for quantum information science; and for applications of quantum sensors. Here we report the design and performance of a…
We describe the operation of a free-space confocal optical microscope operated in a dilution refrigerator. The microscope is installed on a cold insertable probe to enable fast sample exchange while the refrigerator is held at low…
A levitated nanomechanical oscillator under ultra-high vacuum (UHV) is highly isolated from its environment. It has been predicted that this isolation leads to very low mechanical dissipation rates. However, a gap persists between…
We develop a method to transform a collection of higher-dimensional spin systems from the thermal state with a very high temperature of a local spin-s Hamiltonian to a low-lying energy eigenstate of the same. The procedure utilizes an…
Al-doped ZnO thin films were deposited using reactive high power impulse magnetron sputtering at substrate temperatures between room temperature and 600 $\bullet$ C. Two sample series with different oxygen partial pressures were studied.…
At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer…