Related papers: Tropospheric Phase Calibration in Millimeter Inter…
Further analysis has been made on the millimeter and submillimeter-wave (100-1600 GHz or 3 mm - 188 micron) atmospheric opacity data taken with the Fourier Transform Spectrometer (FTS) at Pampa la Bola, 4800 m above sea level in northern…
The light from a source at a distance d will arrive at detectors separated by 100 AU at times that differ by as much as 120 (d/100 Mpc)^{-1} nanoseconds because of the curvature of the wavefront. At gigahertz frequencies, the arrival time…
Interferometric calibration always yields non unique solutions. It is therefore essential to remove these ambiguities before the solutions could be used in any further modeling of the sky, the instrument or propagation effects such as the…
Precise measurements in optical and atomic systems often rely on differential interferometry. This method allows to handle large and correlated phase noise contributions -- such as environmental vibrations, thermal fluctuations, or…
In this document we layout a new method to achieve "bona fide" high precision Very-Long-Baseline-Interferometry (VLBI) astrometric measurements of frequency-dependent positions of celestial sources (even) in the high (mm-wavelength)…
The tropopause is the boundary between the troposphere and the stratosphere, so its height determines the nature of processes in the atmosphere and depends on them. The criterion for determining the height of the tropopause is a decrease in…
We present an optical method to measure radio-frequency electro-optic phase modulation profiles by employing spectrum-to-time mapping realized by highly chirped optical pulses. We directly characterize temporal phase modulation profiles of…
Accurate flux density calibration is essential for precise analysis and interpretation of observations across different observation modes and instruments. In this research, we firstly introduce the flux calibration model incorporated in…
There are a lot of oscillatory motions of various kinds in the atmosphere, for example, internal gravity waves (IGW), which have a period less than the time of flight of the radiosonde. Oscillatory motions lead to adiabatic cooling during…
Model calibration consists of using experimental or field data to estimate the unknown parameters of a mathematical model. The presence of model discrepancy and measurement bias in the data complicates this task. Satellite interferograms,…
Strong turbulence conditions create amplitude aberrations through the effects of near-field diffraction. When integrated over long optical path lengths, amplitude aberrations (seen as scintillation) can nullify local areas in the recorded…
We demonstrate Ramsey-Bord\'e (RB) atom interferometry for high performance laser stabilization with fractional frequency instability $<2 \times 10^{-16}$ for timescales between 10 and 1000s. The RB spectroscopy laser interrogates two…
Interferometric gravitational-wave detectors like LIGO need to be able to measure changes in their arm lengths of order $10^{-18}~$m or smaller. This requires very high laser power in order to raise the signal above shot noise. One…
We present an interferometric technique for measuring ultra-small tilts. The information of a tilt in one of the mirrors of a modified Sagnac interferometer is carried by the phase difference between the counter propagating laser beams.…
[abridged] The International LOFAR Telescope is an interferometer with stations spread across Europe. With baselines of up to ~2,000 km, LOFAR has the unique capability of achieving sub-arcsecond resolution at frequencies below 200 MHz,…
We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature…
A Ramsey-type interferometer is suggested, employing a cold trapped ion and two time-delayed off-resonant femtosecond laser pulses. The laser light couples to the molecular polarization anisotropy, inducing rotational wavepacket dynamics.…
We present a catalog of 321 compact radio sources in the declination range 0deg > delta > -30deg. The positions of these sources have been measured with a two-dimensional rms accuracy of 35 milliarcseconds using the NRAO Very Large Array.…
Context: In the search for extrasolar systems by radial velocity technique, a precise wavelength calibration is necessary for high-precision measurements. The choice of the calibrator is a particularly important question in the infra-red…
Instruments for radio astronomical observations have come a long way. While the first telescopes were based on very large dishes and 2-antenna interferometers, current instruments consist of dozens of steerable dishes, whereas future…