Related papers: Tropospheric Phase Calibration in Millimeter Inter…
Atmospheric water vapor causes significant undesired phase fluctuations for the Submillimeter Array (SMA) interferometer, particularly in its highest frequency observing band of 690 GHz. One proposed solution to this atmospheric effect is…
Phase noise caused by an inhomogeneous, time-variable water vapor distribution in our atmosphere reduces the angular resolution, visibility amplitude and coherence time of millimeter and submillimeter wavelength interferometers. We present…
Fluctuating properties of the atmosphere, and in particular its water vapour content, give rise to phase fluctuations of astronomical signals which, if uncorrected, lead to rapid deterioration of performance of (sub)-mm interferometers on…
Path length changes through the atmosphere cause significant errors for astronomical radio interferometry at high frequencies (e.g. 100 GHz). Path length differences typically give rise to a differential excess path of 1mm for antennas…
Phase referencing is a standard calibration procedure in radio interferometry. It allows to detect weak sources by using quasi-simultaneous observations of closeby sources acting as calibrators. Therefore, it is assumed that, for each…
We report on laboratory test results of the Compact Water Vapor Radiometer (CWVR) prototype for the NSF's Karl G. Jansky Very Large Array (VLA), a five-channel design centered around the 22 GHz water vapor line. Fluctuations in precipitable…
We present a Bayesian approach to calculating the coefficients that convert the outputs of ALMA 183 GHz water-vapour radiometers into estimates of path fluctuations which can then be used to correct the observed interferometric…
Interferometers require accurate determination of the array configuration in order to produce reliable observations. A method is presented for finding the maximum-likelihood estimate of the telescope geometry, and of other instrumental…
Calibration of radio interferometric observations becomes increasingly difficult towards lower frequencies. Below ~300 MHz, spatially variant refractions and propagation delays of radio waves traveling through the ionosphere cause phase…
Phase shifting interferometric (PSI) techniques are among the most sensitive phase measurement methods. Owing to its high sensitivity, any minute phase change caused due to environmental instability results into, inaccurate phase…
For the submillimeter band observations, we have been routinely adopting the calibration cycle time of 20-30 minutes, which is the same as any typical centimeter and millimeter band observations. This cycle time, largely corrects only the…
Precision phase readout of optical beat note signals is one of the core techniques required for intersatellite laser interferometry. Future space based gravitational wave detectors like eLISA require such a readout over a wide range of MHz…
In order for telescopes to obtain good and precise images they need to see through atmospheric turbulence. To accomplish this and compensate for atmospheric turbulence we use Adaptive Optics technologies. In this thesis we analyze the…
The Naval Research Laboratory and the National Radio Astronomy Observatory completed implementation of a low frequency capability on the VLA at 73.8 MHz in 1998. This frequency band offers unprecedented sensitivity (~25 mJy/beam) and…
The Atacama Large millimetre/submillimetre Array (ALMA) makes use of water vapour radiometers (WVR), which monitor the atmospheric water vapour line at 183 GHz along the line of sight above each antenna to correct for phase delays…
We demonstrate phase correction of 3 mm VLBI observations using the scanning 18 GHz to 26 GHz water vapour radiometer at Effelsberg and we demonstrate an absolute accuracy of 15 mm in zenith path delay by comparing with GPS and radiosondes.…
Atmospheric propagation effects at millimeter wavelengths can significantly alter the phases of radio signals and reduce the coherence time, putting tight constraints on high frequency Very Long Baseline Interferometry (VLBI) observations.…
Recent experiments in cosmology, particularly those aimed at detecting the faint, redshifted, global 21 cm hydrogen line (depth < ~200 mK, z > 7.5), have imposed stringent new requirements on radiometer calibration. In this work, we present…
Time-resolved atom interferometry, as employed in applications such as gravitational wave detection and searches for ultra-light dark matter, requires precise control over systematic effects. In this work, we investigate phase noise arising…
We present a millimetre-wave site characterisation for the Australia Telescope Compact Array (ATCA) based on nearly 9 years of data from a seeing monitor operating at this facility. The seeing monitor, which measures the phase fluctuations…