English
Related papers

Related papers: Status of the EDELWEISS Experiment

200 papers

EDELWEISS is a direct dark matter search experiment situated in the low radioactivity environment of the Modane Underground Laboratory. The experiment uses Ge detectors at very low temperature in order to identify eventual rare nuclear…

Instrumentation and Methods for Astrophysics · Physics 2009-08-04 Véronique Sanglard

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for…

The EDELWEISS experiment is a direct detection Dark Matter Search, under the form of WIMPs. It uses heat and ionization Ge cryogenic detectors. We present the latest results obtained by the experiment with three new 320g bolometers. At…

Astrophysics · Physics 2007-05-23 Veronique Sanglard

The EDELWEISS experiment is a Direct Dark Matter search using 320 g heat-and-ionization Ge cryogenic detectors. The final results obtained by the EDELWEISS-I stage corresponding to a total of 62 kg.day are presented. The status of…

Astrophysics · Physics 2019-08-14 V. Sanglard

The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of…

Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of…

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months…

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400-g heat-and-ionization cryogenic detectors equipped with Inter-Digit electrodes for the rejection of near-surface events. Results from…

High Energy Physics - Experiment · Physics 2011-06-09 Torrento-Coello , A. S

Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold,…

The EDELWEISS experiment is dedicated to the WIMPs direct search using heat-and-ionization Ge cryogenic detectors. We present the final results obtained by the first stage of the experiment, EDELWEISS-I which used three 320 g bolometers,…

Astrophysics · Physics 2019-08-14 V. Sanglard

EDELWEISS is a direct dark matter search situated in the low radioactivity environment of the Modane Underground Laboratory. The experiment uses Ge detectors at very low temperature in order to identify eventual rare nuclear recoils induced…

Astrophysics · Physics 2008-12-18 S. Scorza

The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g…

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and…

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices…

The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g…

Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and…

The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode…

Cosmology and Nongalactic Astrophysics · Physics 2019-08-13 E. Armengaud

The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more…

The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published…

‹ Prev 1 2 3 10 Next ›