English
Related papers

Related papers: Prototype Imaging Cd-Zn-Te Array Detector

200 papers

Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…

The High Resolution Energetic X-Ray Imager (HREXI) CZT detector development program at Harvard is aimed at developing tiled arrays of finely pixelated CZT detectors for use in wide-field coded aperture 3-200 keV X-ray telescopes. A pixel…

Instrumentation and Methods for Astrophysics · Physics 2020-04-09 Arkadip Basak , Branden Allen , Jaesub Hong , Daniel P. Violette , Jonathan Grindlay

We successfully carried out the first high-altitude balloon flight of a wide-field hard X-ray coded-aperture telescope ProtoEXIST1, which was launched from the Columbia Scientific Balloon Facility at Ft. Sumner, New Mexico on October 9,…

Instrumentation and Methods for Astrophysics · Physics 2015-05-28 J. Hong , B. Allen , J. Grindlay , S. Barthelemy , R. Baker , A. Garson , H. Krawczynski , J. Apple , W. H. Cleveland

Purpose: Developing photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy…

Medical Physics · Physics 2020-03-03 Mats Persson , Adam Wang , Norbert J. Pelc

The detector material Cadmium Zinc Telluride (CZT), known for its high resolution over a broad energy range, is produced mainly by two methods: the Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB) process. This…

Astrophysics · Physics 2008-11-26 I. Jung , H. Krawczynski , A. Burger , M. Guo , M. Groza

We have built a CsI(Tl) gamma-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV gamma-rays from the capture of polarized cold neutrons by…

The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness…

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a…

The Cherenkov Telescope Array is a world-wide project for a new generation of ground-based Cherenkov telescopes of the Imaging class with the aim of exploring the highest energy region of the electromagnetic spectrum. With two planned…

The future ground-based gamma-ray observatory Cherenkov Telescope Array (CTA) will feature multiple types of imaging atmospheric Cherenkov telescopes, each with thousands of pixels. To be affordable, camera concepts for these telescopes…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 S. Funk , D. Jankowsky , H. Katagiri , M. Kraus , A. Okumura , H. Schoorlemmer , A. Shigenaka , H. Tajima , L. Tibaldo , G. Varner , A. Zink , J. Zorn

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

Crystal scintillators provide potential merits for the pursuit of low-energy low-background experiments. A CsI(Tl) scintillating crystal detector is being constructed to study low-energy neutrino physics at a nuclear reactor, while projects…

High Energy Physics - Experiment · Physics 2011-07-19 Y. Liu , TEXONO Collaboration

Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial…

Instrumentation and Detectors · Physics 2007-05-23 V. D. Ryzhikov , S. V. Naydenov , D. N. Kozin , E. K. Lisetskaya , A. D. Opolonin , V. M. Svishch , T. V. Kulik

We present methods to improve the energy resolution of single-channel, room-temperature Cadmium-Zinc-Telluride (CZT) detectors. A new preamplifier design enables the acquisition of the actual transient current from the crystals and…

Instrumentation and Detectors · Physics 2008-11-26 Y. Ramachers , D. Y. Stewart

The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…

Instrumentation and Detectors · Physics 2015-10-28 S. R. Mirfayzi

A 1M- and a 4M-pixel monolithic CMOS active pixel sensor with 9.5x9.5 micron^2 pixels have been developed for direct imaging in transmission electron microscopy as part of the TEAM project. We present the design and a full characterisation…

We have developed a prototype hexagonal light concentrator for the Large-Sized Telescopes of the Cherenkov Telescope Array. To maximize the photodetection efficiency of the focal-plane camera pixels for atmospheric Cherenkov photons and to…

Building on the successful development of the 10 $\mu m$ HgCdTe detector arrays for the proposed NEOCam mission, the University of Rochester Infrared Detector team and Teledyne Imaging Systems are working together to extend the cutoff…

Instrumentation and Methods for Astrophysics · Physics 2019-09-19 Mario S. Cabrera , Craig W. McMurtry , Meghan L. Dorn , William J. Forrest , Judith L. Pipher , Donald Lee

IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS…

Instrumentation and Methods for Astrophysics · Physics 2021-02-04 Olivier Gevin , Francis Lugiez , Alicja Michalowska , Aline Meuris , Olivier Limousin , Eric Delagnes , Olivier Lemaire , Frédéric Pinsard