Related papers: First results from the UBC etch-alignment mosaic C…
The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come…
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor featuring pixels of 30um x 37.5um and a small collection diode. The sensor is fabricated in a 180 nm CMOS imaging process, using two different pixel flavours: the first with a…
The "Bonn University Simultaneous CAmera" (BUSCA) is a CCD camera system which allows simultaneous direct imaging of the same sky area in four colors. The optics are designed for an f/8 beam and four 4Kx4K CCDs with 15m pixels covering a…
Due to the increasing dimension, complexity and cost of the future astronomical surveys, new technologies enabling more compact and simpler systems are required. The development of curved detectors allows to enhance the performances of the…
We recently initiated a search for ultra-compact dwarf galaxies (UCDs) in the Centaurus galaxy cluster (Mieske et al. 2007), resulting in the discovery of 27 compact objects with -12.2<M_V<-10.9 mag. Our overall survey completeness was…
Direct imaging of exoplanets requires very high contrast levels, which are obtained using coronagraphs. But residual quasi-static aberrations create speckles in the focal plane downstream of the coronagraph which mask the planet. This…
The brighter-fatter effect affects all CCD sensors to various degrees. Deep-depleted thick sensors are seriously affected and the measurement of galaxy shapes for cosmic shear measurements requires an accurate correction of the effect in…
We characterize the response of a novel 250 $\mu$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable,…
In conventional 2D DCE-US, motion correction algorithms take advantage of accompanying side-by-side anatomical Bmode images that contain time-stable features. However, current commercial models of 3D DCE-US do not provide side-by-side Bmode…
We report a time-resolved single photon counting (TCSPC) imaging system based on a line-scanning architecture. The system benefits from the high fill-factor, active area, and large dimension of an advanced CMOS single photon avalanche diode…
3D silicon detectors, in which the electrodes penetrate the sensor bulk perpendicular to the surface, have recently undergone a rapid development from R\&D over industrialisation to their first installation in a real high-energy-physics…
Demand for lightweight, highly reflective and mechanically compliant mirrors for optics experiments has seen a significant surge. In this aspect, photonic crystal (PhC) membranes are ideal alternatives to conventional mirrors, as they…
A novel method nicknamed ELASTIC is proposed for the alignment of multiple-aperture telescopes, in particular segmented telescopes. It only needs the acquisition of two diversity images of an unresolved source, and is based on the…
Crystals are the elementary constituents of Laue lenses, an emerging technology which could allow the realization of a space borne telescope 10 to 100 times more sensitive than existing ones in the 100 keV - 1.5 MeV energy range. This study…
Digital images from crystals, as projected from the third spatial dimension and recorded in atomic resolution with any kind of real-world microscope, feature necessarily broken symmetries of the translation-periodicity-restricted Euclidean…
We demonstrate ground-based submillimagnitude (<10^-3) photometry of widely separated bright stars using snapshot CCD imaging. We routinely achieved this photometric precision by (1) choosing nearby comparison stars of a similar magnitude…
One of the basic parameters of a CCD camera is its gain, i.e. the number of detected electrons per output Analogue to Digital Unit (ADU). This is normally determined by finding the statistical variances from a series of flat-field exposures…
In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeter size at 10 micrometer resolution, the mechanical instability of the scanning stage (+/-10 micrometers) exceeded the resolution of the image…
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells…
In this paper a new technique is presented that extracts the geometry of lumbar vertebral bodies from spiral CT scans. Our new multi-step segmentation approach yields highly accurate and precise measurement of the bone mineral density (BMD)…