English
Related papers

Related papers: EDELWEISS-II : Status and future

200 papers

EDELWEISS-2 is a Ge-bolometer experiment located in the underground laboratory Laboratoire Souterrain de Modane (LSM, France). For the second phase of the experiment, the collaboration has developed new cryogenic detectors with an improved…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Valentin Kozlov

The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g…

The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and…

The EDELWEISS collaboration is searching for WIMP dark matter using natural Ge cryogenic detectors. The whole data set of the first phase of the experiment contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present (7.8%),…

The Cryogenic Dark Matter Search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering interaction with the target nuclei. The current analysis of 397.8 kg-days Ge exposure resulted in…

Astrophysics · Physics 2019-08-13 T. Bruch

We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to…

Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold,…

The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a…

This mini-review first introduces the motivations for Dark Matter Searches. The experimental aspect of the direct detection of Weakly Interactive Massive Particles (WIMPs) is described, detailing its principle and presenting some…

Astrophysics · Physics 2019-08-14 V. Sanglard

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for…

The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are…

The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of…

Cosmology and Nongalactic Astrophysics · Physics 2015-03-19 CDMS , EDELWEISS Collaborations , : , Z. Ahmed , D. S. Akerib , E. Armengaud , S. Arrenberg , C. Augier , C. N. Bailey , D. Balakishiyeva , L. Baudis , D. A. Bauer , A. Benoît , L. Bergé , J. Blümer , P. L. Brink , A. Broniatowski , T. Bruch , V. Brudanin , R. Bunker , B. Cabrera , D. O. Caldwell , B. Censier , M. Chapellier , G. Chardin , F. Charlieux , J. Cooley , P. Coulter , G. A. Cox , P. Cushman , M. Daal , X. Defay , M. De Jesus , F. DeJongh , P. C. F. Di Stefano , Y. Dolgorouki , J. Domange , L. Dumoulin , M. R. Dragowsky , K. Eitel , S. Fallows , E. Figueroa-Feliciano , J. Filippini , D. Filosofov , N. Fourches , J. Fox , M. Fritts , J. Gascon , G. Gerbier , J. Gironnet , S. R. Golwala , M. Gros , J. Hall , R. Hennings-Yeomans , S. Henry , S. A. Hertel , S. Hervé , D. Holmgren , L. Hsu , M. E. Huber , A. Juillard , O. Kamaev , M. Kiveni , H. Kluck , M. Kos , V. Kozlov , H. Kraus , V. A. Kudryavtsev , S. W. Leman , S. Liu , P. Loaiza , R. Mahapatra , V. Mandic , S. Marnieros , C. Martinez , K. A. McCarthy , N. Mirabolfathi , D. Moore , P. Nadeau , X-F. Navick , H. Nelson , C. Nones , R. W. Ogburn , E. Olivieri , P. Pari , L. Pattavina , B. Paul , A. Phipps , M. Pyle , X. Qiu , W. Rau , A. Reisetter , Y. Ricci , M. Robinson , S. Rozov , T. Saab , B. Sadoulet , J. Sander , V. Sanglard , B. Schmidt , R. W. Schnee , S. Scorza , D. N. Seitz , S. Semikh , B. Serfass , K. M. Sundqvist , M. Tarka , A. S. Torrento-Coello , L. Vagneron , M. -A. Verdier , R. J. Walker , P. Wikus , E. Yakushev , S. Yellin , J. Yoo , B. A. Young , J. Zhang

The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge…

The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering of target nuclei. The last analysis with an germanium exposure of 397.8 kg-days resulted in zero…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 T. Bruch

We report first results from the Cryogenic Dark Matter Search (CDMS II) experiment running with its full complement of 30 cryogenic particle detectors at the Soudan Underground Laboratory. This report is based on the analysis of data…

Astrophysics · Physics 2012-08-27 CDMS Collaboration

The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of…

The Edelweiss collaboration performs light Dark Matter (DM) particles searches with germanium bolometer collecting charge and phonon signals. Thanks to the Neganov-Trofimov-Luke (NTL) effect, a RMS resolution of 4.46 electron-hole pairs was…

Astrophysics of Galaxies · Physics 2022-11-16 H. Lattaud

The aim of the SELENDIS project within the EDELWEISS collaboration is to observe single $e^- h^+$ pairs in lightweight (3.3 g) cryogenic germanium bolometers with charge and phonon readout at biases up to $\sim 100$ V. These devices are…

Instrumentation and Detectors · Physics 2022-09-07 H. Lattaud , Q. Arnaud , J. Billard , J. Colas , L. Dumoulin , M. De Jésus , A. Juillard , J. Gascon , S. Marnieros , C. Oriol

We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in…