English
Related papers

Related papers: Test of Thick Pixelated Orbotech Detectors with an…

200 papers

Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent…

We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector, referred to as ``CZT1,'' consisted of a 10 mm x 10 mm x 2 mm CZT crystal with a single gold planar…

Astrophysics · Physics 2015-06-24 P. F. Bloser , T. Narita , J. A. Jenkins , M. Perrin , R. Murray , J. E. Grindlay

The quality of Cadmium Zinc Telluride (CZT) detectors is steadily improving. For state of the art detectors, readout noise is thus becoming an increasingly important factor for the overall energy resolution. In this contribution, we present…

Instrumentation and Methods for Astrophysics · Physics 2009-04-01 Alfred Garson , Qiang Li , Ira V. Jung , Paul Dowkontt , Richard Bose , Garry Simburger , Henric Krawczynski

Recent progress in active-edge technology of silicon sensors enables the development of large-area tiled silicon pixel detectors with small dead space between modules by utilizing edgeless sensors. Such technology has been proven in…

Instrumentation and Detectors · Physics 2015-06-23 Jiaguo Zhang , Damaris Tartarotti Maimone , David Pennicard , Milija Sarajlic , Heinz Graafsma

We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm detectors were…

Astrophysics · Physics 2015-06-24 P. F. Bloser , T. Narita , J. A. Jenkins , J. E. Grindlay

We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…

Instrumentation and Methods for Astrophysics · Physics 2023-12-19 Takahiro Minami , Miho Katsuragawa , Shunsaku Nagasawa , Shin'ichiro Takeda , Shin Watanabe , Yutaka Tsuzuki , Tadayuki Takahashi

Spent nuclear fuel imaging before disposal is of utmost importance before long term disposal in dedicated storage facilities. Passive Gamma Emission Tomography (PGET) is an approved method by the International Atomic Energy Agency. The…

The Cadmium Zinc Telluride Imager (CZTI) onboard AstroSat is designed for hard X-ray imaging and spectroscopy in the energy range of 20 - 100 keV. The CZT detectors are of 5 mm thickness and hence have good efficiency for Compton…

Instrumentation and Methods for Astrophysics · Physics 2021-03-01 Abhay Kumar , Tanmoy Chattopadhyay , Santosh V Vadawale , A. R. Rao , Soumya Gupta , Mithun N. P. S. , Varun Bhalerao , Dipankar Bhattacharya

This report summarizes work done during PhD rotation that proposes an algorithm that uses anode- cathode trigger time difference and cathode to anode pulse height ratio to resolve photon event positioning degeneracy in a novel Cadmium Zinc…

Medical Physics · Physics 2018-04-16 Paurakh L. Rajbhandary , Yi Gu , Craig S. Levin

Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$\Omega$cm are presented. Measurements were made before and after…

Instrumentation and Detectors · Physics 2018-08-01 I. Mandić , V. Cindro , A. Gorišek , B. Hiti , G. Kramberger , M. Zavrtanik , M. Mikuž , T. Hemperek

The effect of moderate cooling on CdZnTe semiconductor detectors has been studied for the COBRA experiment. Improvements in energy resolution and low energy threshold were observed and quantified as a function of temperature. Leakage…

Instrumentation and Detectors · Physics 2009-02-02 J. V. Dawson , C. Montag , C. Reeve , J. R. Wilson , K. Zuber

The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness…

3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…

We report detector characteristics and background measurements from two prototype imaging CZT detectors flown on a scientific balloon payload in May 2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals, each with a 4…

We present methods to improve the energy resolution of single-channel, room-temperature Cadmium-Zinc-Telluride (CZT) detectors. A new preamplifier design enables the acquisition of the actual transient current from the crystals and…

Instrumentation and Detectors · Physics 2008-11-26 Y. Ramachers , D. Y. Stewart

Active edge p-on-p silicon pixel detectors with thickness of 100 $\mu$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and…

Instrumentation and Detectors · Physics 2016-02-17 T. Peltola , X. Wu , J. Kalliopuska , C. Granja , J. Jakubek , M. Jakubek , J. Härkönen , A. Gädda

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave…

Presented is a work on the performance studies of Cadmium Zinc Telluride (CZT) planar detector structures. Current-voltage (IV), capacitance-voltage (CV), and gamma- and alpha-spectroscopy measurements were carried out to provide the…

Instrumentation and Detectors · Physics 2025-12-03 N. Kramarenko , M. Väänänen , M. Kalliokoski , M. Bezak , R. Turpeinen , A. Winkler

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting…

Instrumentation and Detectors · Physics 2018-01-23 nEXO Collaboration , M. Jewell , A. Schubert , W. R. Cen , J. Dalmasson , R. DeVoe , L. Fabris , G. Gratta , A. Jamil , G. Li , A. Odian , M. Patel , A. Pocar , D. Qiu , Q. Wang , L. J. Wen , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. Barbeau , D. Beck , V. Belov , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , G. F. Cao , L. Cao , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , A. Craycraft , W. Cree , M. Côté , T. Daniels , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , T. Didberidze , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , W. Fairbank , J. Farine , S. Feyzbakhsh , R. Fontaine , D. Fudenberg , G. Giacomini , R. Gornea , E. V. Hansen , D. Harris , M. Hasan , M. Heffner , E. W. Hoppe , A. House , P. Hufschmidt , M. Hughes , J. Hößl , Y. Ito , A. Iverson , X. S. Jiang , S. Johnston , A. Karelin , L. J. Kaufman , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , D. S. Leonard , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , B. Mong , D. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , K. Odgers , M. Oriunno , J. L. Orrell , I. Ostrovskiy , C. T. Overman , G. S. Ortega , S. Parent , A. Piepke , J. -F. Pratte , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retiere , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Z. Xuan , L. Yang , D. Yayun , Y. -R. Yen , O. Zeldovich , X. Zhang , J. Zhao , N. Zhe , Y. Zhou , T. Ziegler

In the near future there will be the request for very large liquid Xenon (LXe) detectors for Dark Matter (DM) searches in the 50-ton range. To avoid an impractically long, single drift space of a dual-phase detector, it seems beneficial to…

Instrumentation and Detectors · Physics 2021-09-01 P. Juyal , K. L. Giboni , X. Ji , J. Liu