Related papers: The NICMOS Polarimetric Calibration
Polarization imaging can yield crucial information in multiple applications of remote sensing, such as characterization of clouds, aerosols, and the Aurora Borealis. Some applications require sub-percent polarimetric sensitivity and…
We present a method of cross-calibrating the polarization angle of a polarimeter using BICEP Galactic observations. \bicep\ was a ground based experiment using an array of 49 pairs of polarization sensitive bolometers observing from the…
A simple, self-calibrating, rotating-waveplate polarimeter is largely insensitive to light intensity fluctuations and is shown to be useful for determining the Stokes parameters of light. This study shows how to minimize the in situ…
Polarization leakage of foreground synchrotron emission is a critical issue in HI intensity mapping experiments. While the sought-after HI emission is unpolarized, polarized foregrounds such as Galactic and extragalactic synchrotron…
We are developing an imaging polarimeter by combining a fine-pixel CMOS image sensor with a coded aperture mask as part of the cipher project, aiming to achieve X-ray polarimetry in the energy range of…
Controlling polarisation directly at low temperature is crucial for development of optical spectroscopy techniques at sub-Kelvin temperatures, for example, in a hybrid scheme where light is fed into and collected in the cryostat by fibres…
We report here the performance and first results of the new multiband optical polarimeter DIPOL-1, installed at the Sierra Nevada Observatory 90 cm T90 telescope (SNO, Granada, Spain). DIPOL-1 is equipped with a plane parallel calcite plate…
We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…
An easily constructed and operated polarimeter precisely determines the relative Stokes parameters that characterize the polarization of laser light. The polarimeter is calibrated in situ without removing or realigning its optical elements,…
After a short analysis of the main problems involved in the construction of a Far Infrared polarimeter with very low instrumental noise, we describe the instrument that will be employed at MITO telescope to search for calibration sources…
We present on-sky polarimetric observations with the Gemini Planet Imager (GPI) obtained at straight Cassegrain focus on the Gemini South 8-m telescope. Observations of polarimetric calibrator stars, ranging from nearly unpolarized to…
The process of data taking, reduction and calibration of near-infrared imaging polarimetry data taken with the ESO Adaptive Optics System ADONIS is described. The ADONIS polarimetric facility is provided by a rotating wire grid polarizer.…
We report on the results of calibrating and simulating the instrumental polarization properties of the ESO VLT adaptive optics camera system NAOS/CONICA (NACO) in the Ks-band. We use the Stokes/Mueller formalism for metallic reflections to…
In-line polarimeters perform non-destructive polarization measurements of optical signals, and play a critical role in monitoring and controlling the polarization environment in for example optical networks. While current in-line…
This study is concerned with the design of a Mueller imaging polarimeter for the visualization of spatially-varying Mueller matrix fields. A simplified calibration procedure is advocated, where all the optical elements are calibrated…
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary MOS (CMOS) pixel detector with small pixel size and employ it…
Precision measurements of the polarization of the cosmic microwave background (CMB) radiation, especially experiments seeking to detect the odd-parity "B-modes", have far-reaching implications for cosmology. To detect the B-modes generated…
We utilize the localization analysis method to precisely determine the light beam positions with the spatial separation beyond the optical diffraction limit. By such a direct spatial measurement, the associated optical setup is built to…
Double-pass polarimetry measures the polarization properties of a sample over a range of polar angles and all azimuths. Here, we present a tolerance analysis of all the optical elements in both the calibration and measurement procedures to…
We present an assessment of the CMB large scale anomalies in polarisation using the two-point correlation function as a test case. We employ the state of the art of large scale polarisation datasets: the first based on a Planck 2018 HFI 100…