English
Related papers

Related papers: SPI energy calibration

200 papers

The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting…

Instrumentation and Detectors · Physics 2016-02-17 Daniel Maier , Olivier Limousin

The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii) in-flight calibration of the instrumental…

We present the analysis of the first observations of the Cygnus region by the SPI spectrometer onboard the Integral Gamma Ray Observatory, encompassing ${\sim}$ 600 ks of data. Three sources namely Cyg X-1, Cyg X-3 and EXO 2030+375 were…

Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…

Instrumentation and Detectors · Physics 2023-03-07 Mayank Goswami , Kajal Kumari

Measuring the polarization of the prompt gamma-ray emission from GRBs can significantly improve our understanding of both the GRB emission mechanisms, as well as the underlying engine driving the explosion. We searched for polarization in…

Astrophysics · Physics 2015-06-24 E. Kalemci , S. E. Boggs , C. Kouveliotou , M. Finger , M. G. Baring

The SDHCAL prototype that was completed in 2012 was exposed to beams of pions, electrons of different energies at the SPS of CERN for a total time period of 5 weeks. The data are being analyzed within the CALICE Collaboration. However…

Instrumentation and Detectors · Physics 2014-06-30 Alexey Petrukhin

The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of…

Instrumentation and Detectors · Physics 2021-03-09 Luciano Brunetti , Luca Oberto , Marco Sellone

Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation.…

Instrumentation and Detectors · Physics 2026-04-23 Marco Salathe , Nicolas Abgrall , Mark S. Bandstra , Tenzing H. Y. Joshi , Brian J. Quiter , Reynold J. Cooper

The stability ofthe proportional--integral--derivative (PID)controlof temperature in the spark plasma sintering (SPS) process is investigated.ThePID regulationsof this process are tested fordifferent SPS toolingdimensions, physical…

Applied Physics · Physics 2020-11-25 Charles Manière , Geuntak Lee , Eugene A. Olevsky

The spectrometer aboard INTEGRAL, SPI, has the capability to detect the signature of polarised emission from a bright gamma-ray source. GRB 041219a is the most intense burst localised by INTEGRAL and is an ideal candidate for such a study.…

Astrophysics · Physics 2009-11-13 S. McGlynn , D. J. Clark , A. J. Dean , L. Hanlon , S. McBreen , D. R. Willis , B. McBreen , A. J. Bird , S. Foley

We conduct a series of measurements on the thermodynamic properties of an optically-trapped strongly interacting Fermi gas, including the energy $E$, entropy $S$, and sound velocity $c$. Our model-independent measurements of $E$ and $S$…

Other Condensed Matter · Physics 2009-11-13 Le Luo , John E. Thomas

Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…

Instrumentation and Detectors · Physics 2020-04-08 B. Blank , P. Ascher , M. Gerbaux , J. Giovinazzo , S. Grevy , T. Kurtukian Nieto , M. Versteegen , J. C. Thomas

We compare the absolute gain photometric calibration of the Planck/HFI and Herschel/SPIRE instruments on diffuse emission. The absolute calibration of HFI and SPIRE each relies on planet flux measurements and comparison with theoretical…

The calculation of self-energy corrections to the electron bands of a metal requires the evaluation of the intraband contribution to the polarizability in the small-q limit. When neglected, as in standard GW codes for semiconductors and…

Materials Science · Physics 2009-11-13 Marco Cazzaniga , Nicola Manini , Luca Guido Molinari , Giovanni Onida

We investigated the dependence of spectral lag on energy band based on 28 bright GRBs detected by the SPI and IBIS/ISGRI instruments on the INTEGRAL observatory. It is found that for simple structured bursts or well separated pulses of…

High Energy Astrophysical Phenomena · Physics 2013-04-02 P. Minaev , A. Pozanenko , S. Grebenev , S. Molkov

We study numerically the scaling correction to the internal energy per spin as a function of system size and temperature in a variety of Ising and vector spin glasses. From a standard scaling analysis we estimate the effective size…

Disordered Systems and Neural Networks · Physics 2007-05-23 Helmut G. Katzgraber , I. A. Campbell

Scanning Thermal Microscopy (SThM) is a scanning probe technique aimed at quantitative characterization of local thermal properties at the length scale down to tens of nanometers. With many probe designs and approaches to interpretation of…

Materials Science · Physics 2024-09-12 Alexander Tselev

Silicon and germanium are perhaps the two most well-understood semiconductor materials in the context of solid state device technologies and more recently micromachining and nanotechnology. Meanwhile, these two materials are also important…

Optics · Physics 2009-11-11 Bradley J. Frey , Douglas B. Leviton , Timothy J. Madison

ASTRI SST-2M is one of the prototypes of the small size class of telescopes proposed for the Cherenkov Telescope Array. Its optical design is based on a dual-mirror Schwarzschild-Couder configuration, and the camera is composed by a matrix…

Instrumentation and Methods for Astrophysics · Physics 2016-12-08 D. Impiombato , O. Catalano , S. Giarrusso , T. Mineo , G. La Rosa , C. Gargano , P. Sangiorgi , A. Segreto , G. Sottile , G. Bonanno , S. Garozzo , A. Grillo , D. Marano , G. Romeo , R. Gimenes

We present recent improvements in polarization analysis with the INTEGRAL SPI data. The SPI detector plane consists of 19 independent Ge crystals and can operate as a polarimeter. The anisotropy characteristics of Compton diffusions can…

Instrumentation and Methods for Astrophysics · Physics 2015-06-15 M. Chauvin , J. P. Roques , D. J. Clark , E. Jourdain