Related papers: The Planck Low Frequency Instrument
This paper describes the processing applied to the HFI cleaned time-ordered data to produce photometrically calibrated maps. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To get the best accuracy on the…
This paper describes the identification, modelling, and removal of previously unexplained systematic effects in the polarization data of the Planck High Frequency Instrument (HFI) on large angular scales, including new mapmaking and…
We present a description of the pipeline used to calibrate the Planck Low Frequency Instrument (LFI) timelines into thermodynamic temperatures for the Planck 2015 data release, covering four years of uninterrupted operations. As in the 2013…
This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from…
This paper describes the mapmaking procedure applied to Planck LFI (Low Frequency Instrument) data. The mapmaking step takes as input the calibrated timelines and pointing information. The main products are sky maps of $I,Q$, and $U$ Stokes…
Data on board the future PLANCK Low Frequency Instrument (LFI), to measure the Cosmic Microwave Background (CMB) anisotropies, consist of $N$ differential temperature measurements, expanding a range of values we shall call $R$. Preliminary…
The Microwave Anisotropy Probe and Planck missions will provide low noise maps of the temperature of the cosmic microwave background (CMB). These maps will allow measurement of the power spectrum of the CMB with measurement noise below…
Accurate measurement of the cosmic microwave background (CMB) anisotropy requires precise knowledge of the instrument beam. We explore how well the Planck beams will be determined from observations of planets, developing techniques that are…
The expected data rate produced by the Low Frequency Instrument (LFI) planned to fly on the ESA Planck mission in 2007, is over a factor 8 larger than the bandwidth allowed by the spacecraft transmission system to download the LFI data. We…
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed…
We present simulations of observations with the 143 GHz channel of the Planck High Frequency Instrument (HFI). These simulations are performed over the entire sky, using the true angular resolution of this channel: 8 arcmin FWHM, 3.5 arcmin…
We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an…
The Planck satellite will observe the full sky at nine frequencies from 30 to 857 GHz. The goal of this paper is to examine the effects of four realistic instrument systematics in the 30 GHz frequency maps: non-axially-symmetric beams,…
For 40 years, the cosmic microwave background (CMB) has been the most important source of information about the geometry and contents of the Universe. Even so, only a small fraction of the information available in the CMB has been extracted…
We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the Orbital Dipole plus the Solar Dipole, caused respectively by the…
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission…
We use an iterative generalized least squares map-making algorithm, in conjunction with Monte Carlo techniques, to obtain estimates of the angular power spectrum from cosmic microwave background (CMB) maps. This is achieved by…
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an…
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered…
We present Planck LFI frequency sky maps derived within the BeyondPlanck framework. This framework draws samples from a global posterior distribution that includes instrumental, astrophysical and cosmological parameters, and the main…