English
Related papers

Related papers: A Prototype Si/CdTe Compton Camera and the Polariz…

200 papers

We present a novel way of wavefront sensing using a commercially available, continuous-wave time-of-flight camera with QVGA-resolution. This CMOS phase camera is capable of sensing externally modulated light sources with frequencies up to…

Instrumentation and Detectors · Physics 2021-08-18 Erik Muñiz , Varun Srivastava , Subham Vidyant , Stefan W. Ballmer

\textit{Topmetal-${II}^-$} is a low noise CMOS pixel direct charge sensor with a pitch of 83$\mu m$. CdZnTe is an excellent semiconductor material for radiation detection. The combination of CdZnTe and the sensor makes it possible to build…

Instrumentation and Detectors · Physics 2017-02-22 Shuguang Zou , Yan Fan , Xiangming Sun , Guangming Huang , Hua Pei , Zhen Wang , Jun Liu , Ping Yang , Dong Wang

X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…

Instrumentation and Detectors · Physics 2021-01-26 Moa Yveborg , Cheng Xu , Erik Fredenberg , Mats Danielsson

Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…

Instrumentation and Detectors · Physics 2015-06-17 Qing Lin , Yuehuan Wei , Jie Bao , Jie Hu , Xinran Li , Wolfgang Lorenzon , Kaixuan Ni , Michael Schubnell , Mengjiao Xiao , Xiang Xiao

We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the…

Characteristics improvement of photon/plasmon detectors have been the subject of several investigations in the area of plasmonic integrated circuits. Among different suggestions, Silicon-based Metal-Semiconductor-Metal (MSM) waveguides are…

Applied Physics · Physics 2019-01-31 Elahe Rastegar Pashaki , Hassan Kaatuzian , Abdolber Mallah Livani

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between…

Instrumentation and Methods for Astrophysics · Physics 2022-08-10 Giulio Lucchetta , Markus Ackermann , David Berge , Ingo Bloch , Rolf Bühler , Hermann Kolanoski , Wolfgang Lange , Francesco Zappon

We report on a new photon-counting detector possessing unprecedented spatial resolution, moderate spectral resolution and high background-rejection capability for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and…

Astrophysics · Physics 2009-11-10 E. Miyata , K. Tamura

Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe…

Instrumentation and Detectors · Physics 2017-10-04 I. Israelashvili , A. E. C. Coimbra , D. Vartsky , L. Arazi , S. Shchemelinin , E. N. Caspi , A. Breskin

We present a concept for an imaging gamma-ray polarimeter operating from ~50 MeV to ~1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The…

Astrophysics · Physics 2009-11-10 P. F. Bloser , S. D. Hunter , G. O. Depaola , F. Longo

Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an…

An innovative X-ray imaging sensor with intrinsic digital characteristics is presented. It is based on Chromatic Photon Counting technology. The detector is able to count individually the incident X-ray photons and to separate them…

Instrumentation and Detectors · Physics 2015-06-11 R. Bellazzini , G. Spandre , A. Brez , M. Minuti , M. Pinchera , P. Mozzo

Using 2.0 cm x 2.0 cm x 0.5 cm Cadmium Telluride (CdTe) substrates from the company Acrorad, we have fabricated detectors with planar cathode contacts and 8x8 anode pixels. We investigate the I-V characteristics and energy resolution of the…

Astrophysics · Physics 2007-05-23 A. B. Garson , I. V. Jung , J. Perkins , H. Krawczynski

CdTe is increasingly being used as the x-ray sensing material in imaging pixel array detectors for x-rays, generally above 20 keV, where silicon sensors become unacceptably transparent. Unfortunately CdTe suffers from polarization, which…

The shape of the undepleted volume of a p-type high-purity Broad Energy Germanium detector, dependent on the bias voltage, has been imaged by measuring spatially-resolved Compton-scattering efficiency. The bias voltage was raised stepwise…

Instrumentation and Detectors · Physics 2026-02-18 Iris Abt , Arthur Butorev , Felix Hagemann , David Hervas Aguilar , Johanna Lührs , Julia Penner , Oliver Schulz

POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40…

The Compton Spectrometer and Imager (COSI) is a balloon-borne gamma-ray (0.2-5 MeV) telescope with inherent sensitivity to polarization. COSI's main goal is to study astrophysical sources such as $\gamma$-ray bursts, positron annihilation,…

We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The…

Instrumentation and Detectors · Physics 2009-11-13 A. Kastalsky , S. Luryi , B. Spivak

Compton backscattering polarimetry provides a fast and accurate method to measure the polarization of an electron beam in a storage ring. Since the method is non-destructive, the polarization of the electron beam can be monitored during…

Instrumentation and Detectors · Physics 2007-05-23 I. Passchier , D. W. Higinbotham , C. W. de Jager , B. E. Norum , N. H. Papadakis , N. P. Vodinas
‹ Prev 1 4 5 6 7 8 10 Next ›