Related papers: Development of a Si/CdTe semiconductor Compton tel…
The Compton Spectrometer and Imager (COSI) is a gamma-ray survey telescope utilizing a compact Compton imager design, enabled by an array of 16 high-resolution germanium cross-strip detectors. After its launch into an equatorial Low Earth…
We present three spectra of Cygnus X-1 in the low/hard state from 3-1000 keV produced with RXTE and OSSE. We demonstrate that a pure thermal Comptonization model, with Compton reflection fits the data well, with coronal temperatures of…
The Advanced Compton Telescope (ACT) has been suggested to be the optimal next-generation instrument to study nuclear gamma-ray lines. In this work, we investigate the potential of three hypothetical designs of the ACT to perform SN…
Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for…
The preliminary design of the new space gamma-ray telescope GAMMA-400 for the energy range 100 MeV - 3 TeV is presented. The angular resolution of the instrument, 1-2{\deg} at E{\gamma} ~100 MeV and ~0.01^{\circ} at E{\gamma} > 100 GeV, its…
We present the design and testing of a compact, low-cost stellar spectrometer developed for undergraduate and outreach applications. The instrument employs a 600 lines/mm diffraction grating, a CMOS monochrome sensor, and a 3D-printed mount…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
Previous analyses of point sources in the gamma-ray range were done either below 30 MeV or above 100 MeV. Below 30 MeV, the imaging Compton telescope (COMPTEL) onboard NASA's Compton Gamma-Ray Observatory detected 26 steady sources in the…
X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…
New mid-infrared HgCdTe (MCT) detector arrays developed in collaboration with Teledyne Imaging Sensors (TIS) have paved the way for improved 10-$\mu$m sensors for space- and ground-based observatories. Building on the successful development…
The sky at MeV energies is currently poorly explored. Here we present an innovative mission concept that builds on and improves past and currently proposed missions at such energies. We outline the motivations for combining a coded mask and…
New generation Cadmium Telluride (CZT & CdTe) solid state detectors can provide high quantum efficiency with reasonably good energy resolution and can operate at near room temperature; an unique advantage for space experiments. We present…
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard…
The low-energy $\gamma$-ray (0.1-30 MeV) sky has been relatively unexplored since the decommissioning of the COMPTEL instrument on the Compton Gamma-Ray Observatory (CGRO) satellite in 2000. However, the study of this part of the energy…
It has been a general trend to develop low-voltage electron microscopes due to their high imaging contrast of the sample and low radiation damage. Atom-resolved transmission electron microscopes with voltages as low as 15-40 kV have been…
Spectral analysis is one of the most powerful technologies for studying and understanding matter. As the devices for spectral analysis, spectrometers are widely used in material detection, isotope analysis, trace gas detection, and the…
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in…
\textit{Topmetal-${II}^-$} is a low noise CMOS pixel direct charge sensor with a pitch of 83$\mu m$. CdZnTe is an excellent semiconductor material for radiation detection. The combination of CdZnTe and the sensor makes it possible to build…
Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the…
A novel Compton Scanner setup has been built, commissioned and operated at the Max-Planck-Institute for Physics in Munich to collect pulses from bulk events in high-purity germanium detectors for pulse shape studies. In this fully automated…