Related papers: X-ray to UV Variability Correlation in MCG-6-30-15
Quiescent emission from the neutron star low-mass X-ray binary Cen X-4 is seen to be variable on timescales from hundreds of seconds to years, suggesting that at least in this object, low-level accretion is important during quiescence. Here…
We have undertaken near-continuous monitoring of the Seyfert 1 galaxy NGC 7469 in the X-ray with RXTE over a ~30d baseline. The source shows strong variability with a root-mean-square (rms) amplitude of ~16 per cent, and peak-to-peak…
This paper presents a comprehensive examination of the X-ray continuum variability of the bright Seyfert 1 galaxy MCG-6-30-15. The source clearly shows the strong, linear correlation between rms variability amplitude and flux first seen in…
We analyze observations of the Seyfert galaxy NGC 4151 covering 90 years in the optical band and 27 years in the 2-10 keV X-ray band. We compute the Normalized Power Spectrum Density (NPSD), the Structure Function (SF) and the…
We present results of a 3 year monitoring campaign of the Seyfert 1 galaxy Markarian 509, using X-ray data from the Rossi X-ray Timing Explorer (RXTE) and optical data taken by the SMARTS consortium. Both light curves show significant…
Short-term variability of X-ray continuum spectra has been reported for several Active Galactic Nuclei. Significant X-ray flux variations are observed within time scales down to 10^3-10^5 seconds. We discuss short variability time scales in…
To investigate further the comparison between AGN and black hole X-ray binaries, we have studied the main X-ray variability properties of the Seyfert 1 Galaxy Markarian 335. We put particular emphasis on the X-ray time lags, which is a…
Recent intense X-ray and UV monitoring campaigns with Swift have detected clear UV lags behind X-ray in several local active galactic nuclei (AGNs). The UV to X-ray lags are often larger (by a factor up to ~ 20) than expected if the UV…
We use time domain analysis techniques to investigate the rapid variability of Cygnus X-1. We show that the cross-correlation functions between hard and soft energy bands reach values very close to unity and peak at a lag of less than 2…
We analyse the spectra of the archival XMM-Newton data of the Seyfert 1 AGN Zw 229.015 in the energy range $0.3 - 10.0$ keV. When fitted with a simple power-law, the spectrum shows signatures of weak soft excess below 1.0 keV. We find that…
One of the most important features in active galactic nuclei (AGN) is the variability of their emission. Variability has been discovered at X-ray, UV, and radio frequencies on time scales from hours to years. Among the AGN family and…
With currently available XMM-Newton EPIC pn observations spanned over about 3 years, we present a detailed spectral and temporal variability of the 0.2--10 keV X-ray emission from the X-ray bright BL Lac object PKS 2155-304. The spectral…
We have used all 20 archival XMM-Newton observations of PKS 2155-304 with simultaneous X-ray and UV/optical data to study its long term flux and spectral variability. We find significant variations, in all bands, on time-scales of years…
Active galactic nuclei (AGNs) are known to be variable across all wavelengths. Significant observational efforts have been invested in the last decade in studying their ultraviolet (UV) and optical variability. Long and densely sampled,…
We report the results of intensive X-ray, UV and optical monitoring of the Seyfert 1 galaxy NGC 4593 with Swift. There is no intrinsic flux-related spectral change in the the variable components in any band with small apparent variations…
Swift monitoring of NGC 4151 with ~6 hr sampling over a total of 69 days in early 2016 is used to construct light curves covering five bands in the X-rays (0.3-50 keV) and six in the ultraviolet (UV)/optical (1900-5500 A). The three hardest…
Intensive broadband reverberation mapping campaigns have shown that AGN variability is significantly more complex than expected from disc reverberation of the variable X-ray illumination. The UV/optical variability is highly correlated and…
The first seven years of RXTE monitoring of Seyfert 1 active galactic nuclei have been systematically analyzed to yield five homogeneous samples of 2-12 keV light curves, probing hard X-ray variability on successively longer durations from…
The gamma-ray blazar 3C 279 was monitored on a nearly daily basis with IUE, ROSAT and EGRET for three weeks between December 1992 and January 1993. During this period, the blazar was at a historical minimum at all wavelengths. Here we…
The focus of NASA's Swift telescope has been transients and target-of-opportunity observing, resulting in many observations of ultraluminous X-ray sources (ULXs) over the last ~20 years. For the vast majority of these observations,…