We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture…
The Modified Horizontal Bridgman (MHB) process produces Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity. Various groups,including our own, previously reported on the test of 2x2x0.5 cm3 MHB CZT detectors…
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system…
We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as…
We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm detectors were…
Measuring the depth of interaction in thick Cadmium-Zinc-Telluride (CZT) detectors allows improved imaging and spectroscopy for hard X-ray imaging above 100 keV. The Energetic X-ray Imaging Survey Telescope (EXIST) will employ relatively…
Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to 600…
We describe the detector development for a balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe,…
We are currently developing Cadmium Zinc Telluride (CZT) detectors for a next-generation space-borne hard X-ray telescope which can follow up on the highly successful NuSTAR (Nuclear Spectroscopic Telescope Array) mission. Since the launch…
We are currently investigating the spatial resolution of highly pixelated Cadmium Zinc Telluride (CZT) detector for imaging applications. A 20 mm {\times} 20 mm {\times} 5 mm CZT substrate was fabricated with 600 {\mu}m pitch pixels (500…
Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over the broad energy range from several keV into the MeV energy range. In this paper we present the results of a systematic study of the…
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent…
Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their…
We have constructed a moderately large area (32 cm2), fine pixel (2.5 mm pixel, 5 mm thick) CZT imaging detector which constitutes the first section of a detector module (256 cm2) developed for a balloon-borne wide-field hard X-ray…
We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High…
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and {\gamma}-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT detectors for the…
The proposed black-hole finder mission EXIST will consist of multiple wide-field hard X-ray coded-aperture telescopes. The high science goals set for the mission require innovations in telescope design. In particular, wide energy band…
A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 micron thick cadmium telluride (CdTe) sensor. The full…
We report detector characteristics and background measurements from two prototype imaging CZT detectors flown on a scientific balloon payload in May 2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals, each with a 4…
Cadmium zinc telluride (CdZnTe, CZT) radiation detectors are suitable for a variety of applications, due to their high spatial resolution and spectroscopic energy performance at room temperature. However, state-of-the-art detector systems…