English
Related papers

Related papers: A charge transfer inefficiency correction model fo…

200 papers

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…

Astrophysics · Physics 2009-11-07 Catherine E. Grant , Gregory Y. Prigozhin , Beverly LaMarr , Mark W. Bautz

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…

Astrophysics · Physics 2009-11-11 C. E. Grant , M. W. Bautz , S. M. Kissel , B. LaMarr , G. Y. Prigozhin

The front-illuminated (FI) CCDs in the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory (Chandra) were damaged in the extreme environment of the Earth's radiation belts, causing charge traps that result in enhanced…

Astrophysics · Physics 2015-06-24 L. K. Townsley , P. S. Broos , J. A. Nousek , G. P. Garmire

The ACIS front-illuminated CCDs onboard the Chandra X-ray Observatory were damaged in the extreme environment of the Earth's radiation belts, resulting in enhanced charge transfer inefficiency (CTI). This produces a row dependence in gain,…

Astrophysics · Physics 2009-10-31 L. K. Townsley , P. S. Broos , G. P. Garmire , J. A. Nousek

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…

Astrophysics · Physics 2009-11-11 C. E. Grant , M. W. Bautz , S. E. Kissel , B. LaMarr , G. Y. Prigozhin

We discuss the flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO). The spectral resolution and sensitivity of the ACIS instrument have both been evolving…

The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons…

Instrumentation and Methods for Astrophysics · Physics 2015-05-19 C. E. Grant , B. LaMarr , M. W. Bautz , S. L. O'Dell

After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of…

Astrophysics · Physics 2009-11-13 C. E. Grant , B. LaMarr , G. Y. Prigozhin , S. E. Kissel , S. K. Brown , M. W. Bautz

Radiation damage to space-based Charge-Coupled Device (CCD) detectors creates defects which result in an increasing Charge Transfer Inefficiency (CTI) that causes spurious image trailing. Most of the trailing can be corrected during…

Instrumentation and Methods for Astrophysics · Physics 2015-08-26 Holger Israel , Richard Massey , Thibaut Prod'homme , Mark Cropper , Oliver Cordes , Jason Gow , Ralf Kohley , Ole Marggraf , Sami Niemi , Jason Rhodes , Alex Short , Peter Verhoeve

We have investigated the radiation damage effects on a CCD to be employed in the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray Image (MAXI) onboard the International Space Station (ISS). Since low energy protons…

Instrumentation and Detectors · Physics 2009-11-07 E. Miyata , T. Kamazuka , H. Kouno , M. Fukuda M. Mihara , K. Matsuta , H. Tsunemi , K. Tanaka , T Minamisono , H. Tomida , K. Miyaguchi

Charge-Coupled Device (CCD) detectors, widely used to obtain digital imaging, can be damaged by high energy radiation. Degraded images appear blurred, because of an effect known as Charge Transfer Inefficiency (CTI), which trails bright…

Instrumentation and Methods for Astrophysics · Physics 2014-03-05 Richard Massey , Tim Schrabback , Oliver Cordes , Ole Marggraf , Holger Israel , Lance Miller , David Hall , Mark Cropper , Thibaut Prod'homme , Sami-Matias Niemi

The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented…

Instrumentation and Methods for Astrophysics · Physics 2015-06-05 C. E. Grant , P. G. Ford , M. W. Bautz , S. L. O'Dell

As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Catherine E. Grant , Mark W. Bautz , Peter G. Ford , Paul P. Plucinsky

Charge Transfer Inefficiency (CTI) due to radiation damage above the Earth's atmosphere creates spurious trailing in Hubble Space Telescope (HST) images. Radiation damage also creates unrelated warm pixels - but these happen to be perfect…

Cosmology and Nongalactic Astrophysics · Physics 2014-11-20 Richard Massey , Chris Stoughton , Alexie Leauthaud , Jason Rhodes , Anton Koekemoer , Richard Ellis , Edgar Shaghoulian

Current optical space telescopes rely upon silicon Charge Coupled Devices (CCDs) to detect and image the incoming photons. The performance of a CCD detector depends on its ability to transfer electrons through the silicon efficiently, so…

Instrumentation and Methods for Astrophysics · Physics 2015-05-27 T. Prod'homme , A. G. A. Brown , L. Lindegren , A. D. T. Short , S. W. Brown

The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is…

We use an empirical approach to characterize the effect of charge-transfer efficiency (CTE) losses in images taken with the Wide-Field Channel of the Advanced Camera for Surveys. The study is based on profiles of warm pixels in 168 dark…

Instrumentation and Methods for Astrophysics · Physics 2015-05-19 Jay Anderson , Luigi R. Bedin

(Abridged) We examine the effects of charge transfer inefficiency (CTI) during CCD readout on galaxy shape measurements required by studies of weak gravitational lensing. We simulate a CCD readout with CTI such as that caused by charged…

Instrumentation and Methods for Astrophysics · Physics 2014-11-20 Jason Rhodes , Alexie Leauthaud , Chris Stoughton , Richard Massey , Kyle Dawson , William Kolbe , Natalie Roe

A variety of on-orbit imaging and spectroscopic observations are used to characterize the Charge Transfer Efficiency (CTE) of the Charge-Coupled Device (CCD) of the Space Telescope Imaging Spectrograph (STIS) aboard the Hubble Space…

Astrophysics · Physics 2009-11-11 Paul Goudfrooij , Ralph C. Bohlin , Jesus Maiz-Apellaniz , Randy A. Kimble
‹ Prev 1 2 3 10 Next ›