English
Related papers

Related papers: The Infrared Array Camera (IRAC) for the Spitzer S…

200 papers

With a possible angular resolution down to 0.1-0.2 millisecond of arc using the 330 m baselines and the access to the 600-900 nm spectral domain, the CHARA Array is ideally configured for focusing on precise and accurate fundamental…

We present 3.6, 4.5, 5.8, 8.0, 24, and 70 micron images of the Crab Nebula obtained with the Spitzer Space Telescope IRAC and MIPS cameras, Low- and High-resolution Spitzer IRS spectra of selected positions within the nebula, and a…

We study 87 Extremely Red Objects (EROs), selected both to have color redder than R-[3.6] = 4.0, and to have confirmed spectroscopic redshifts. Together, these two constraints result in this sample populating a fairly narrow redshift range…

A 3D ISAR security imaging experiment at 24GHz is demonstrated with a sparse MIMO array. The MIMO array is an 8Tx/16Rx linear array to achieve real-aperture imaging along the vertical dimension. It is time-switching multiplexed with a…

Signal Processing · Electrical Eng. & Systems 2020-12-30 Zhanyu Zhu , Feng Xu

We present Spitzer Space Telescope IRAC and MIPS observations toward a sample of nine high-mass star forming regions at a distance of around 2 kpc. Based on IRAC and MIPS 24 $\mu$m photometric results and 2MASS JHKs data, we carry out a…

We present the optical design of OPTICAM-ARG, a multi-channel instrument for the simultaneous acquisition of images in three spectral bands at the Cassegrain focus of an f/8.5 telescope, covering the 0.35 to 1.00 um wavelength range. The…

Instrumentation and Methods for Astrophysics · Physics 2026-05-13 M. R. Najera , J. Herrera Vazquez , E. Luna , A. Castro , D. Altamirano , R. Michel , S. A. Cellone , E. Sohn

The FourStar infrared camera is a 1.0-2.5 micron (JHKs) near infrared camera for the Magellan Baade 6.5m telescope at Las Campanas Observatory (Chile). It is being built by Carnegie Observatories and the Instrument Development Group at…

IRIS (InfraRed Imaging Spectrograph) is the diffraction-limited first light instrument for the Thirty Meter Telescope (TMT) that consists of a near-infrared (0.84 to 2.4 $\mu$m) imager and integral field spectrograph (IFS). The IFS makes…

High speed mid-wave infrared (MWIR) photodetectors have important applications in the emerging areas such high-precision frequency comb spectroscopy and light detection and ranging (LIDAR). In this work, we report a high-speed…

Applied Physics · Physics 2020-12-30 Zhiyang Xie , Jian Huang , Xuliang Chai , Zhuo Deng , Yaojiang Chen , Qi Lu , Zhicheng Xu , Jianxin Chen , Yi Zhou , Baile Chen

We present the innovative macro-slicer optical and opto-mechanical designs for the third-generation Mid-resolution InfraReD Astronomical Spectrograph (MIRADAS) instrument for the 10.4m Gran Telescopio Canarias (GTC) in the 1-2.5 $\mu$m…

Instrumentation and Methods for Astrophysics · Physics 2019-02-06 R Deno Stelter , Stephen S Eikenberry

The IRAC mapping of the NMBS-II fields program is an imaging survey at 3.6 and 4.5$\mu$m with the Spitzer Infrared Array Camera (IRAC). The observations cover three Canada-France-Hawaii Telescope Legacy Survey Deep (CFHTLS-D) fields,…

Infrared avalanche photodiode arrays represent a panacea for many branches of astronomy by enabling extremely low-noise, high-speed and even photon-counting measurements at near-infrared wavelengths. We recently demonstrated the use of an…

Instrumentation and Methods for Astrophysics · Physics 2015-08-19 Christoph Baranec , Dani Atkinson , Reed Riddle , Donald Hall , Shane Jacobson , Nicholas M. Law , Mark Chun

The absolute flux calibration of the James Webb Space Telescope will be based on a set of stars observed by the Hubble and Spitzer Space Telescopes. In order to cross-calibrate the two facilities, several A, G, and white dwarf (WD) stars…

Multi-wavelength imaging polarimetry at far-infrared wavelengths has proven to be an excellent tool for studying the physical properties of dust, molecular clouds, and magnetic fields in the interstellar medium. Although these wavelengths…

IRAC imaging of a 4'7x4'7 area in the Lockman Hole detected over 400 galaxies in the IRAC 3.6 micron and 4.5 micron bands, 120 in the 5.8 micron, and 80 in the 8 micron bandin 30 minutes of observing time. Color-color diagrams suggest that…

IRIS (InfraRed Imaging Spectrograph) is one of the first-generation instruments for the Thirty Meter Telescope (TMT). IRIS is composed of a combination of near-infrared (0.84--2.4 $\mu$m) diffraction limited imager and integral field…

We present a new infrared survey covering the three Euclid deep fields and four other Euclid calibration fields using Spitzer's Infrared Array Camera (IRAC). We have combined these new observations with all relevant IRAC archival data of…

Astrophysics of Galaxies · Physics 2022-03-14 Andrea Moneti , H. J. McCracken , M. Shuntov , O. B. Kauffmann , P. Capak , I. Davidzon , O. Ilbert , C. Scarlata , S. Toft , J. Weaver , R. Chary , J. Cuby , A. L. Faisst , D. C. Masters , C. McPartland , B. Mobasher , D. B. Sanders , R. Scaramella , D. Stern , I. Szapudi , H. Teplitz , L. Zalesky , A. Amara , N. Auricchio , C. Bodendorf , D. Bonino , E. Branchini , S. Brau-Nogue , M. Brescia , J. Brinchmann , V. Capobianco , C. Carbone , J. Carretero , F. J. Castander , M. Castellano , S. Cavuoti , A. Cimatti , R. Cledassou , G. Congedo , C. J. Conselice , L. Conversi , Y. Copin , L. Corcione , A. Costille , M. Cropper , A. Da Silva , H. Degaudenzi , M. Douspis , F. Dubath , C. A. J. Duncan , X. Dupac , S. Dusini , S. Farrens , S. Ferriol , P. Fosalba , M. Frailis , E. Franceschi , M. Fumana , B. Garilli , B. Gillis , C. Giocoli , B. R. Granett , A. Grazian , F. Grupp , S. V. H. Haugan , H. Hoekstra , W. Holmes , F. Hormuth , P. Hudelot , K. Jahnke , S. Kermiche , A. Kiessling , M. Kilbinger , T. Kitching , R. Kohley , M. Kuemmel , M. Kunz , H. Kurki-Suonio , S. Ligori , P. B. Lilje , I. Lloro , E. Maiorano , O. Mansutti , O. Marggraf , K. Markovic , F. Marulli , R. Massey , S. Maurogordato , M. Meneghetti , E. Merlin , G. Meylan , M. Moresco , L. Moscardini , E. Munari , S. M. Niemi , C. Padilla , S. Paltani , F. Pasian , K. Pedersen , S. Pires , M. Poncet , L. Popa , L. Pozzetti , F. Raison , R. Rebolo , J. Rhodes , H. Rix , M. Roncarelli , E. Rossetti , R. Saglia , P. Schneider , A. Secroun , G. Seidel , S. Serrano , C. Sirignano , G. Sirri , L. Stanco , P. Tallada-Crespi , A. N. Taylor , I. Tereno , R. Toledo-Moreo , F. Torradeflot , Y. Wang , N. Welikala , J. Weller , G. Zamorani , J. Zoubian , S. Andreon , S. Bardelli , S. Camera , J. Gracia-Carpio , E. Medinaceli , S. Mei , G. Polenta , E. Romelli , F. Sureau , M. Tenti , T. Vassallo , A. Zacchei , E. Zucca , C. Baccigalupi , A. Balaguera-Antolinez , F. Bernardeau , A. Biviano , M. Bolzonella , E. Bozzo , C. Burigana , R. Cabanac , A. Cappi , C. S. Carvalho , S. Casas , G. Castignani , C. Colodro-Conde , J. Coupon , H. M. Courtois , D. Di Ferdinando , M. Farina , F. Finelli , P. Flose-Reimberg , S. Fotopoulou , S. Galeotta , K. Ganga , J. Garcia-Bellido , E. Gaztanaga , G. Gozaliasl , I. Hook , B. Joachimi , V. Kansal , E. Keihanen , C. C. Kirkpatrick , V. Lindholm , G. Mainetti , D. Maino , R. Maoli , M. Martinelli , N. Martinet , M. Maturi , R. B. Metcalf , G. Morgante , N. Morisset , A. Nucita , L. Patrizii , D. Potter , A. Renzi , G. Riccio , A. G. Sanchez , D. Sapone , M. Schirmer , M. Schultheis , V. Scottez , E. Sefusatti , R. Teyssier , O. Tubio , I. Tutusaus , J. Valiviita , M. Viel , H. Hildebrandt

I very briefly describe the latest generation near infrared (1-2.5 micron) instruments which are available on, or under development for `large' (D>=3.5 m) telescopes. Most of the imagers under construction are limited to relatively small…

Astrophysics · Physics 2007-05-23 E. Oliva

The Near-Infrared Imager and Slitless Spectrograph (NIRISS) is the science module of the Canadian-built Fine Guidance Sensor (FGS) onboard the James Webb Space Telescope (JWST). NIRISS has four observing modes: 1) broadband imaging…

The Japanese infrared astronomical satellite AKARI performed ~4000 pointed observations for 16 months until the end of 2007 August, when the telescope and instruments were cooled by liquid Helium. Observation targets include solar system…

Instrumentation and Methods for Astrophysics · Physics 2016-02-17 Fumi Egusa , Fumihiko Usui , Kazumi Murata , Takuji Yamashita , Issei Yamamura , Takashi Onaka
‹ Prev 1 3 4 5 6 7 10 Next ›