English
Related papers

Related papers: WARP liquid argon detector for dark matter survey

200 papers

The WARP programme for dark matter search with a double phase argon detector is presented. In such a detector both excitation and ionization produced by an impinging particle are evaluated by the contemporary measurement of primary…

A new method of searching for dark matter in the form of weakly interacting massive particles (WIMP) has been developed with the direct detection of the low energy nuclear recoils observed in a massive target (ultimately many tons) of ultra…

WIMPs are a well-motivated galactic dark matter candidate. Liquid argon (LAr) is an attractive target for the direct detection of WIMPs. The LAr prototype detector is designed to study the technology and property of LAr detector. The…

Instrumentation and Detectors · Physics 2016-12-21 Pei-Xian Li , Meng-Yun Guan , Chang-Gen Yang , Peng Zhang , Jin-Chang Liu , Yong-Pen Zhang , Cong Guo , Yi Wang

DARWIN (dark matter wimp search with noble liquids) is a design study for a next-generation, multi-ton dark matter detector in Europe. Liquid argon and/or liquid xenon are the target media for the direct detection of dark matter candidates…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Laura Baudis

WIMPs (Weakly Interacting Massive Particles) are considered the main candidates for Cold Dark Matter. The ArDM experiment aims at measuring signals directly induced by WIMPs in liquid argon. A 1-ton prototype is currently developed with the…

High Energy Physics - Phenomenology · Physics 2009-11-13 M. Laffranchi , A. Rubbia

Discrimination between electron and nuclear recoil events in a liquid argon scintillation detector has been demonstrated with simulations by using the differences in the scintillation photon time distribution between these classes of…

Astrophysics · Physics 2007-05-23 M. G. Boulay , A. Hime

The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment,…

The Dark Matter part of the universe presumably consists of WIMPs (Weakly Interacting Massive Particles). The ArDM project aims at measuring signals induced by WIMPs in a liquid argon detector. A 1-ton prototype is currently developed with…

High Energy Physics - Phenomenology · Physics 2008-11-26 L. Kaufmann , A. Rubbia

The ArDM project aims at developing and operating large noble liquid detectors to search for direct evidence of Weakly Interacting Massive Particle (WIMP) as Dark Matter in the Universe. The initial goal is to design, assemble and operate a…

High Energy Physics - Phenomenology · Physics 2009-11-11 A. Rubbia

Our group from the University of Zurich is performing R&D work towards the design of a large liquid argon detector to detect Weakly Interacting Massive Particles (WIMPs). This project is developed within the DARWIN Collaboration funded by…

Instrumentation and Detectors · Physics 2015-03-19 C. Amsler

Several experiments have been conducted worldwide, with the goal of observing low-energy nuclear recoils induced by WIMPs scattering off target nuclei in ultra-sensitive, low-background detectors. In the last few decades noble liquid…

Instrumentation and Detectors · Physics 2016-03-23 B. Rossi , A. Anastasio , A. Boiano , S. Catalanotti , A. G. Cocco , G. Covone , P. Di Meo , G. Longo , A. Vanzanella , S. Walker , H. Wang , Y. Wang , G. Fiorillo

Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground…

Instrumentation and Detectors · Physics 2020-09-22 Eric Church , Christopher Jackson , Richard Saldanha

DARWIN (DARk matter WImp search with Noble liquids) is an R&D and design study towards the realization of a multi-ton scale dark matter search facility in Europe, based on the liquid argon and liquid xenon time projection chamber…

Instrumentation and Methods for Astrophysics · Physics 2010-12-22 Laura Baudis

The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to…

Instrumentation and Detectors · Physics 2010-03-26 Christian Regenfus

The DEAP-3600 experiment uses 3.6 tons of liquid argon for a sensitive dark matter search, with a sensitivity to the spin-independent WIMP-nucleon cross-section of $10^{-46}$ cm$^2$ at 100 GeV WIMP mass. This high sensitivity is achievable…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Bei Cai

The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for…

Instrumentation and Methods for Astrophysics · Physics 2019-02-19 P. -A. Amaudruz , M. Baldwin , M. Batygov , B. Beltran , C. E. Bina , D. Bishop , J. Bonatt , G. Boorman , M. G. Boulay , B. Broerman , T. Bromwich , J. F. Bueno , P. M. Burghardt , A. Butcher , B. Cai , S. Chan , M. Chen , R. Chouinard , S. Churchwell , B. T. Cleveland , D. Cranshaw , K. Dering , J. DiGioseffo , S. Dittmeier , F. A. Duncan , M. Dunford , A. Erlandson , N. Fatemighomi , S. Florian , A. Flower , R. J. Ford , R. Gagnon , P. Giampa , V. V. Golovko , P. Gorel , R. Gornea , E. Grace , K. Graham , D. R. Grant , E. Gulyev , A. Hall , A. L. Hallin , M. Hamstra , P. J. Harvey , C. Hearns , C. J. Jillings , O. Kamaev , A. Kemp , M. Kuźniak , S. Langrock , F. La Zia , B. Lehnert , O. Li , J. J. Lidgard , P. Liimatainen , C. Lim , T. Lindner , Y. Linn , S. Liu , P. Majewski , R. Mathew , A. B. McDonald , T. McElroy , K. McFarlane , T. McGinn , J. B. McLaughlin , S. Mead , R. Mehdiyev , C. Mielnichuk , J. Monroe , A. Muir , P. Nadeau , C. Nantais , C. Ng , A. J. Noble , E. O'Dwyer , C. Ohlmann , K. Olchanski , K. S. Olsen , C. Ouellet , P. Pasuthip , S. J. M. Peeters , T. R. Pollmann , E. T. Rand , W. Rau , C. Rethmeier , F. Retière , N. Seeburn , B. Shaw , K. Singhrao , P. Skensved , B. Smith , N. J. T. Smith , T. Sonley , J. Soukup , R. Stainforth , C. Stone , V. Strickland , B. Sur , J. Tang , J. Taylor , L. Veloce , E. Vázquez-Jáuregui , J. Walding , M. Ward , S. Westerdale , R. White , E. Woolsey , J. Zielinski

ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon underground detector. The…

Instrumentation and Detectors · Physics 2015-05-13 Vittorio Boccone

We assess the prospects for indirect detection of Weakly Interacting Massive Particles using a large Liquid Argon TPC detector. Signal events will consist of energetic electron (anti)neutrinos coming from the decay of $\tau$ leptons and $b$…

High Energy Physics - Phenomenology · Physics 2008-11-26 A. Bueno , R. Cid , S. Navas-Concha , D. Hooper , T. J. Weiler

DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally…

Instrumentation and Methods for Astrophysics · Physics 2016-12-02 J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , C. Amsler , E. Aprile , L. Arazi , F. Arneodo , P. Barrow , L. Baudis , M. L. Benabderrahmane , T. Berger , B. Beskers , A. Breskin , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Buetikofer , J. Calven , J. M. R. Cardoso , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , S. Diglio , G. Drexlin , E. Duchovni , E. Erdal , G. Eurin , A. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , P. Di Gangi , A. Di Giovanni , M. Galloway , M. Garbini , C. Geis , F. Glueck , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , V. Hannen , E. Hogenbirk , J. Howlett , D. Hilk , C. Hils , A. James , B. Kaminsky , S. Kazama , B. Kilminster , A. Kish , L. M. Krauss , H. Landsman , R. F. Lang , Q. Lin , F. L. Linde , S. Lindemann , M. Lindner , J. A. M. Lopes , T. Marrodan Undagoitia , J. Masbou , F. V. Massoli , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. D. Mora , E. Morteau , M. Murra , J. Naganoma , J. L. Newstead , K. Ni , U. Oberlack , P. Pakarha , B. Pelssers , P. de Perio , R. Persiani , F. Piastra , M. C. Piro , G. Plante , L. Rauch , S. Reichard , A. Rizzo , N. Rupp , J. M. F. Dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , M. Schumann , J. Schreiner , L. Scotto Lavina , M. Selvi , P. Shagin , M. C. Silva , H. Simgen , P. Sissol , M. von Sivers , D. Thers , J. Thurn , A. Tiseni , R. Trotta , C. D. Tunnell , K. Valerius , M. A. Vargas , H. Wang , Y. Wei , C. Weinheimer , T. Wester , J. Wulf , Y. Zhang , T. Zhu , K. Zuber

The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xenon nuclei. With a fiducial mass of 1000 kg of liquid xenon, a sufficiently low…

Astrophysics · Physics 2007-05-23 XENON Collaboration , Elena Aprile
‹ Prev 1 2 3 10 Next ›