Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…

Astrophysics · Physics 2009-11-10 C. E. Grant , M. W. Bautz , S. M. Kissel , B. LaMarr

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…

Astrophysics · Physics 2009-11-11 C. E. Grant , M. W. Bautz , S. M. Kissel , B. LaMarr , G. Y. Prigozhin

We discuss the flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO). The spectral resolution and sensitivity of the ACIS instrument have both been evolving…

The ACIS front-illuminated CCDs onboard the Chandra X-ray Observatory were damaged in the extreme environment of the Earth's radiation belts, resulting in enhanced charge transfer inefficiency (CTI). This produces a row dependence in gain,…

Astrophysics · Physics 2009-10-31 L. K. Townsley , P. S. Broos , G. P. Garmire , J. A. Nousek

The front-illuminated (FI) CCDs in the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory (Chandra) were damaged in the extreme environment of the Earth's radiation belts, causing charge traps that result in enhanced…

Astrophysics · Physics 2015-06-24 L. K. Townsley , P. S. Broos , J. A. Nousek , G. P. Garmire

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…

Astrophysics · Physics 2009-11-11 C. E. Grant , M. W. Bautz , S. E. Kissel , B. LaMarr , G. Y. Prigozhin

The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons…

Instrumentation and Methods for Astrophysics · Physics 2015-05-19 C. E. Grant , B. LaMarr , M. W. Bautz , S. L. O'Dell

After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of…

Astrophysics · Physics 2009-11-13 C. E. Grant , B. LaMarr , G. Y. Prigozhin , S. E. Kissel , S. K. Brown , M. W. Bautz

As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Catherine E. Grant , Mark W. Bautz , Peter G. Ford , Paul P. Plucinsky

The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented…

Instrumentation and Methods for Astrophysics · Physics 2015-06-05 C. E. Grant , P. G. Ford , M. W. Bautz , S. L. O'Dell

As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory completes a quarter century of on orbit operations, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved…

Instrumentation and Methods for Astrophysics · Physics 2024-06-27 Catherine E. Grant , Marshall W. Bautz , Paul P. Plucinsky , Peter G. Ford

Radiation damage to space-based Charge-Coupled Device (CCD) detectors creates defects which result in an increasing Charge Transfer Inefficiency (CTI) that causes spurious image trailing. Most of the trailing can be corrected during…

Instrumentation and Methods for Astrophysics · Physics 2015-08-26 Holger Israel , Richard Massey , Thibaut Prod'homme , Mark Cropper , Oliver Cordes , Jason Gow , Ralf Kohley , Ole Marggraf , Sami Niemi , Jason Rhodes , Alex Short , Peter Verhoeve

The flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) below 1.5 keV is difficult because of the lack of strong lines in the calibration source on-board the Chandra X-ray Observatory. We have been…

We have investigated the radiation damage effects on a CCD to be employed in the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray Image (MAXI) onboard the International Space Station (ISS). Since low energy protons…

Instrumentation and Detectors · Physics 2009-11-07 E. Miyata , T. Kamazuka , H. Kouno , M. Fukuda M. Mihara , K. Matsuta , H. Tsunemi , K. Tanaka , T Minamisono , H. Tomida , K. Miyaguchi

Charge-Coupled Device (CCD) detectors, widely used to obtain digital imaging, can be damaged by high energy radiation. Degraded images appear blurred, because of an effect known as Charge Transfer Inefficiency (CTI), which trails bright…

Instrumentation and Methods for Astrophysics · Physics 2014-03-05 Richard Massey , Tim Schrabback , Oliver Cordes , Ole Marggraf , Holger Israel , Lance Miller , David Hall , Mark Cropper , Thibaut Prod'homme , Sami-Matias Niemi

The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of…

The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is…

The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the…

PLATO is designed to detect Earth-sized exoplanets around solar-type stars and to measure their radii with accuracy better than \(2\%\) via the transit method. Charge transfer inefficiency (CTI), a by-product of radiation damage to CCDs,…

Earth and Planetary Astrophysics · Physics 2026-03-18 Shaunak Mishra , Reza Samadi , Diane Bérard