English
Related papers

Related papers: A Low Noise Thermometer Readout for Ruthenium Oxid…

200 papers

The second generation Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE 2) instrument is a balloon-borne experiment to measure the radiometric temperature of the cosmic microwave background and Galactic and…

Instrumentation and Methods for Astrophysics · Physics 2011-03-21 J. Singal , D. J. Fixsen , A. Kogut , S. Levin , M. Limon , P. Lubin , P. Mirel , M. Seiffert , T. Villela , E. Wollack , C. A. Wuensche

The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument to measure the temperature of the cosmic microwave background at centimeter wavelengths. ARCADE uses narrow-band cryogenic…

Astrophysics · Physics 2009-11-10 A. Kogut , D. J. Fixsen , S. Levin , M. Limon , P. M. Lubin , P. Mirel , M. Seiffert , E. Wollack

The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument designed to measure the temperature of the cosmic microwave background at centimeter wavelengths. ARCADE searches for…

Astrophysics · Physics 2009-11-11 A. Kogut , D. Fixsen , S. Fixsen , S. Levin , M. Limon , L. Lowe , P. Mirel , M. Seiffert , J. Singal , P. Lubin , E. Wollack

The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming…

Cosmology and Nongalactic Astrophysics · Physics 2016-10-05 D. J. Fixsen , A. Kogut , S. Levin , M. Limon , P. Lubin , P. Mirel , M. Seiffert , J. Singal , E. Wollack , T. Villela , C. A. Wuensche

We describe the design and calibration of an external cryogenic blackbody calibrator used for the first two flights of the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The calibrator consists of…

Astrophysics · Physics 2009-11-10 A. Kogut , E. Wollack , D. J. Fixsen , M. Limon , P. Mirel , S. Levin , M. Seiffert , P. M. Lubin

We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $\Omega$ down to 0.2 m$\mathrm{\Omega}$. This results in…

We report the results of an effort to measure the low frequency portion of the spectrum of the Cosmic Microwave Background Radiation (CMB), using a balloon-borne instrument called ARCADE (Absolute Radiometer for Cosmology, Astrophysics, and…

Astrophysics · Physics 2009-11-10 D. J. Fixsen , A. Kogut , S. Levin , M. Limon , P. Lubin , P. Mirel , M. Seiffert , E. Wollack

Structure formation in the early universe is expected to produce a cosmological background of free-free emission. The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) will measure the spectrum of the cosmic…

Astrophysics · Physics 2015-06-24 A. Kogut

In electrically substituted radiometers, the ultra low noise control of the temperature is required. In this framework, we present results dedicated to the temperature regulation of copper plates, 3 cm diameter and 1 mm thick, using…

Instrumentation and Detectors · Physics 2016-11-18 Bruno Guillet , Didier Robbes , Laurence Mechin

We have designed low noise temperature sensing and control units with the objective of using them for the fabrication of far infrared active cavity radiometers. The sensing unit, first characterized at 300K using industrial platinium…

Instrumentation and Detectors · Physics 2016-09-08 B. Guillet , D. Robbes , L. Mechin

We demonstrate a blackbody radiation thermometer based on optically excited rubidium atoms in a vapor cell. The temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We resolve temperature with a…

The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…

Mesoscale and Nanoscale Physics · Physics 2011-02-01 D. J. Goldie , D. M. Glowacka , K. Rostem† , S. Withington

We present a precise thermometry system to monitor room-temperature components of a telescope for radio-astronomy such as cosmic microwave background (CMB) observation. The system realizes precision of 1 mK${\rm \sqrt{s}}$ on a timescale of…

Instrumentation and Methods for Astrophysics · Physics 2022-10-04 Daiki Tanabe , Masaya Hasegawa , Masashi Hazumi , Nobuhiko Katayama , Shuhei Kikuchi , Adrian Lee , Haruki Nishino , Satoru Takakura

Dedicated read-out electronics was developed for low impedance resistive thermometers. Using this high performance temperature controller, the temperature dependence of the excess noise of a YBa2Cu307-d (YBCO) sample in the superconducting…

Superconductivity · Physics 2007-05-23 B. Guillet , L. Mechin , D. Robbes

We developed a simple, flexible, low-cost, and computer-controlled cryogenic temperature measurement system for undergraduate instructional laboratories. An Arduino microcontroller board measures the voltage across a silicon diode to…

Physics Education · Physics 2020-01-29 Woong Sung Lee

The characterization of the optical properties of the atmosphere in the near UV, in particular the tropospheric aerosol stratification, clouds optical depth and spatial distribution are common in the field of atmospheric physics, due to…

Instrumentation and Methods for Astrophysics · Physics 2014-03-25 M. Buscemi , C. Cassardo , M. Cilmo , M. Coco , S. Ferrarese , F. Guarino , A. S. Tonachini , L. Valore , L. Wiencke

We describe a compact calorimeter that opens ultra-low temperature heat capacity studies of small metal crystals in moderate magnetic fields. The performance is demonstrated on the canonical heavy Fermion metal YbRh2Si2. Thermometry is…

Instrumentation and Detectors · Physics 2024-07-02 Jan Knapp , Lev V. Levitin , Ján Nyéki , Manuel Brando , John Saunders

A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…

Instrumentation and Methods for Astrophysics · Physics 2011-09-19 Eric W. Bryerton

Optical measurement of the motion of a 940 kHz mechanical resonance of a silicon nitride nanostring resonator is demonstrated with a read out noise imprecision reaching 37 dB below that of the resonator's zero-point fluctuations. Via…

Optics · Physics 2015-06-04 Alex G. Krause , Tim D. Blasius , Oskar Painter

This paper presents an ultra-low noise L-band radio astronomical cryogenic receiver for FAST telescope. The development of key low noise microwave parts of Coupling-LNA and conical quad-ridge OMT and reasonable system integration achieve…

Instrumentation and Methods for Astrophysics · Physics 2021-09-08 Hong-Fei Liu , Chuan He , Jin Wang , Peng Jiang , Sheng-Wang Wang , Yang Wu , Hang Zhang , Jin-You Song , Xiang-Wei Shi , Ming-Lei Guo
‹ Prev 1 2 3 10 Next ›