Related papers: UV-IR Science Prospects with TES Imaging Arrays
Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the…
Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs…
Superconducting transition-edge sensors (TESs) carried by X-ray telescopes are powerful tools for the study of neutron stars and black holes. Several methods, such as optimal filtering or principal component analysis, have already been…
Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
Large arrays of superconducting transition-edge sensor (TES) microcalorimeters are becoming the key technology for future space-based X-ray observatories and ground-based experiments in the fields of astrophysics, laboratory astrophysics,…
The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…
Transition-edge sensors (TESs) have the potential to perform electron spectroscopic measurements with far greater measurement rates and efficiencies than can be achieved using existing electron spectrometers. Existing spectrometers filter…
In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of…
The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
We compare methods for signal classification applied to voltage traces from transition-edge sensors (TES) which are photon-number resolving detectors fundamental for accessing quantum advantages in information processing, communication and…
Transition-Edge Sensors (TESs) are very effective photon-number-resolving (PNR) detectors that have enabled many photonic quantum technologies. However, their relatively slow thermal recovery time severely limits their operation rate in…
Transition edge sensors (TESs) are superconducting energy-resolving microcalorimeters that have demonstrated low background rates as well as quantum efficiencies close to unity for photons at optical and near-infrared wavelengths. This…
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum…
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $\Delta E$ < 3 eV full-width-half-maximum (FWHM) in the soft…
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically…
We present the first detection of electrons with kinetic energy in the 100 eV range with transition-edge sensors (TESs). This has been achieved with a $(100\times 100)$ $\mu$m$^2$ Ti-Au bilayer TES, with a critical temperature of about 84…
At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to…