Related papers: Single Dish Polarization Calibration
In this paper, we present a study of orthogonal polarization modes in the radio emission of PSR B1133+16, conducted within the frame of simultaneous, multi-frequency, single-pulse observations. Simultaneously observing at two frequencies…
The CARMA 1.3 mm polarization system consists of dual-polarization receivers that are sensitive to right- (R) and left-circular (L) polarization, and a spectral-line correlator that measures all four cross polarizations (RR, LL, LR, RL) on…
This tutorial reviews the mathematical foundations of single-antenna radio polarimetry with the aim of fostering a conceptual understanding of the relationships between a physical description of signal propagation (gain, delay, reflection,…
Polarization profiles are presented for 20 millisecond pulsars that are being observed as part of the Parkes Pulsar Timing Array project. The observations used the Parkes multibeam receiver with a central frequency of 1369 MHz and the…
The nature of coherent radio emission is still challenging even after more than half a century of pulsar discovery, but it is generally a consensus that single-pulse observations are essential for probing the magnetospheric dynamics,…
A telescope polarization model for the SST [Swedish 1-m Solar Telescope] is developed and the parameters of this model are fitted to polarization measurements made with a 1-meter linear polarizer in front of the entrance window. In this…
We present a method based on Mueller calculus to calibrate linear polarimetric observations. The key advantages of the proposed way of calibration are: (1) that it can be implemented in a data reduction pipeline, (2) that it is possible to…
Polarization leakage of foreground synchrotron emission is a critical issue in HI intensity mapping experiments. While the sought-after HI emission is unpolarized, polarized foregrounds such as Galactic and extragalactic synchrotron…
The BICEP3 CMB Polarimeter is a small-aperture refracting telescope located at the South Pole and is specifically designed to search for the possible signature of inflationary gravitational waves in the Cosmic Microwave Background (CMB).…
POLAR is a dedicated Gamma-Ray Burst polarimeter making use of Compton-scattering which took data from the second Chinese spacelab, the Tiangong-2 from September 2016 to April 2017. It has a wide Field of View of $\sim6$ steradians and an…
In recent years, handheld and portable terahertz instruments have been in rapid development for various applications ranging from non-destructive testing to biomedical imaging and sensing. For instance, we have deployed our Portable…
In a cycle of papers, starting with the present one, a fundamental possibility of the polarization sounding of a pulsar magnetosphere using pulsar self-radiation as a test signal will be considered. The main idea of such a sounding is based…
We present polarisation profiles for 48 southern pulsars observed with the new 10-cm receiver at the Parkes telescope. We have exploited the low system temperature and high bandwidth of the receiver to obtain profiles which have good signal…
The Gas Pixel Detector is an X-ray polarimeter to fly on-board IXPE and other missions. To correctly measure the source polarization, the response of IXPE's GPDs to unpolarized radiation has to be calibrated and corrected. In this paper we…
The radio polarization properties of the pulsar population are only superficially captured by the conventional picture of pulsar radio emission. We study the broadband polarization of 271 young radio pulsars, focusing particularly on…
During February 2016, CSIRO Astronomy and Space Science and the Max-Planck-Institute for Radio Astronomy installed, commissioned and carried out science observations with a phased array feed (PAF) receiver system on the 64m diameter Parkes…
We developed a specific numerical fitting procedure, based on the least squares method, to calculate the parameters of the polarization ellipse by only using a single polarizer and a detection device for measuring the outgoing intensities.
We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…
We report on polarimetric observations of 100 pulsars centered on 774 MHz, made using the Green Bank Telescope, presenting their polarization profiles and polarized flux densities and comparing them with previous observations when possible.…
We describe the Submillimeter Array (SMA) Polarimeter, a polarization converter and feed multiplexer installed on the SMA. The polarimeter uses narrow-band quarter-wave plates to generate circular polarization sensitivity from the…