Related papers: Spectral response of the EPIC-pn detector: basic d…
The photosystem II reaction center (PSII-RC) performs the primary energy conversion steps of oxygenic photosynthesis. While the PSII-RC has been studied extensively, the similar timescales of energy transfer and charge separation, and the…
This article details the potential for using Charge Coupled Devices (CCD) to detect low-energy neutrinos through their coherent scattering with nuclei. The detection of neutrinos through this standard model process has not been accessible…
X-ray echo spectroscopy, a space-domain counterpart of neutron spin echo, is a recently proposed inelastic x-ray scattering (IXS) technique. X-ray echo spectroscopy relies on imaging IXS spectra, and does not require x-ray…
We present a study of the in-flight performance of the XMM-Newton EPIC MOS and pn detectors, with focus on the influence of proton flares and vignetting on the data. The very wide range in the conditions of our sample of observations, in…
In this paper we briefly review the state-of-the-art of intrinsic photon-number resolution (PNR) with superconducting nanowire single-photon detectors (SNSPDs) and will provide an overview of the various experimental techniques employed to…
We present three observations (four exposures) of Mkn 421 performed by XMM--Newton in the Autumn of 2002, concentrating on the EPIC--PN camera data. The X-ray spectra were soft and steepening toward high energies. The source was highly…
We report for the first time large photoresponse in a single NW of the charge transfer complex Cu:TCNQ. We fabricate a metal-semiconductor-metal device with a single NW and focus ion beam deposited Pt. We observe large photocurrent even at…
A Convolutional Neural Network architecture was used to classify various isotopes of time-sequenced gamma-ray spectra, a typical output of a radiation detection system of a type commonly fielded for security or environmental measurement…
Optoelectronic functionalities of photodection and light harnessing rely on the band-to-band excitation of semiconductors, thus the spectral response of the devices is dictated and limited by their bandgap. A novel approach, free from this…
Position-sensitive detectors for cold and ultra-cold neutrons (UCN) are in use in fundamental research. In particular, measuring the properties of the quantum states of bouncing neutrons requires micro-metric spatial resolution. To this…
We develop an analytic model that relates intensity correlation measurements performed by an image sensor to the properties of photon pairs illuminating it. Experiments using both an effective single-photon counting (SPC) camera and a…
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…
X-ray parametric down-conversion is a fundamental nonlinear effect that promises a wide range of possible applications. Nevertheless, it has been scarcely investigated and unequivocal evidence of the effect is still missing for certain…
We construct a low-temperature microwave waveguide interferometer for measuring high-frequency properties of two-dimensional electron gases (2DEGs). Coupled plasmon-cyclotron resonance (PCR) spectra are used to extract effective mass, bulk…
A model-independent method is proposed to characterize and correct charge sharing spectral distortions in energy-resolved X-ray acquisitions with pixellated photon-counting detectors. The technique is based on the determination of a…
We discuss the methods used to compile a high signal-to-noise dataset representative of both the instrumental and cosmic background signal measured at high galactic latitude by the XMM-Newton EPIC cameras. The characteristics of the EPIC…
Low-energy electronic recoil caused by solar neutrinos in multi-ton xenon detectors is an important subject not only because it is a source of the irreducible background for direct searches of weakly-interacting massive particles (WIMPs),…
Large dynamic range room temperature photon number resolving (PNR) detectors can be very useful for measuring very low light intensities and for analyzing multiphoton quantum states. In this paper we present a PNR detector based on the…
The differential cross section and deuteron analysing powers of the dp -> {pp}n charge-exchange reaction have been measured with the ANKE spectrometer at the COSY storage ring. Using a deuteron beam of energy 1170 MeV, data were obtained…
Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the…