English
Related papers

Related papers: Fabry-Perot observations at the 6m telescope

200 papers

Fiber-fed etalons are widely employed in advanced interferometric instruments such as gravitational-wave detectors, ultrastable lasers and calibration reference for high-precision spectrographs. We demonstrate that variation in near-field…

Instrumentation and Methods for Astrophysics · Physics 2021-05-11 Jun Hao , Liang Tang , Huiqi Ye , Zhibo Hao , Jian Han , Yang Zhai , Kai Zhang , Ruyi Wei , Dong Xiao

The orbits of 8 systems with low-mass components (HIP 14524, HIP 16025, HIP 28671, HIP 46199, HIP 47791, HIP 60444, HIP 61100 and HIP 73085) are presented. Speckle interferometric data were obtained at the 6 m Big Alt-azimuth Special…

Solar and Stellar Astrophysics · Physics 2020-05-29 A. Mitrofanova , V. Dyachenko , A. Beskakotov , Yu. Balega , A. Maksimov , D. Rastegaev , S. Komarinsky

SIMP is a proper motion (PM) survey made with the Observatoire du Mont Megantic (OMM) wide-field near-infrared camera CPAPIR at the CTIO 1.5 m and OMM 1.6 m telescopes. The SIMP observations were initiated in early 2005, are still ongoing…

Astrophysics · Physics 2009-11-13 Etienne Artigau , David Lafreniere , Rene Doyon , Loic Albert , Jasmin Robert , Lison Malo

We have upgraded IRCAL, the near-infrared science camera of the Lick Observatory adaptive optics system, to add a dual-channel imaging polarimetry mode. This mode uses an optically contacted YLF (LiYF_4) Wollaston prism to provide…

Astrophysics · Physics 2009-11-13 Marshall D. Perrin , James R. Graham , James P. Lloyd

Cophasing six telescopes from the CHARA array, the CHARA-Michigan Phasetracker (CHAMP) and Michigan Infrared Combiner (MIRC) are pushing the frontiers of infrared long-baseline interferometric imaging in key scientific areas such as star-…

Instrumentation and Methods for Astrophysics · Physics 2013-12-17 Stefan Kraus , John Monnier , Fabien Baron , Xiao Che , Rafael Millan-Gabet , Natalie Thureau , Ettore Pedretti

The possibility of an Earth-Sun analog beyond our solar system is one of the most longstanding questions in science. At present, answering this question embodies an extremely difficult measurement problem that requires multiple coordinated…

The tip-tilt stabilisation system of the 1.8 m Auxiliary Telescopes of the Very Large Telescope Interferometer was never dimensioned for robust fringe tracking, except when atmospheric seeing conditions are excellent. Increasing the level…

We describe an apparatus for the stabilization of laser frequencies that prevents long term frequency drifts. A Fabry-Perot interferometer is thermostated by referencing it to a stabilized He-Ne laser (master), and its length is scanned…

Instrumentation and Detectors · Physics 2013-09-02 A. Rossi , V. Biancalana. B. Mai , L. Tomassetti

Optimizing on-sky single-mode fiber (SMF) injection is an essential part of developing precise Doppler spectrometers and new astrophotonics technologies. We installed and tested a prototype SMF injection system at the Large Binocular…

Instrumentation and Methods for Astrophysics · Physics 2020-05-22 Andrew J. Bechter , Jonathan Crass , Jonathan Tesch , Justin R. Crepp , Eric B. Bechter

The conventional interpretation of the recent magneto-oscillation experiments in underdoped Cuprates, requires that there be a state of altered translational symmetry in the pseudogap state which is not supported by structural and Angle…

Strongly Correlated Electrons · Physics 2009-11-13 C. M. Varma

I discuss 3 widely applicable aspects concerning calibration of the near infrared adaptive optics integral field spectrometer SINFONI: (1) the accuracy with which one needs to quantify the PSF and how this might be achieved in practice; (2)…

Astrophysics · Physics 2015-06-24 R. Davies

There are several high-performance adaptive optics systems that deliver diffraction-limited imaging on ground-based telescopes, which renewed the interest of single-mode fiber (SMF) spectroscopy for exoplanet characterization. However, the…

Instrumentation and Methods for Astrophysics · Physics 2021-05-19 S. Y. Haffert

Focal Ratio Degradation (FRD) in fibres is a crucial factor to control in astronomical instruments in order to minimize light loss. As astronomical instrumentation has advanced, the integration of large populations of fibres has become…

Instrumentation and Methods for Astrophysics · Physics 2023-06-30 Weimin Sun , Xudong Chen , Jiabin Wang , Hang Jiang , Anzhi Wang , Qi Yan , Zhenyu Ma , Shengjia Wang , Tao Geng , Yue Zhong , Zhongquan Qu , Yunxiang Yan

We discuss how to optimise the science output of the European Solar Telescope (EST), when used without the wide-field compensation for high-altitude seeing that the EST multi conjugate adaptive optics (MCAO) will offer. This will be the…

Instrumentation and Methods for Astrophysics · Physics 2026-05-05 G. B. Scharmer , M. G. Löfdahl , J. de la Cruz Rodríguez , B. Lindberg , H. Socas-Navarro , D. Kiselman , M. Rempel , J. Leenaarts

The fields in multiple-pass interferometers, such as the Fabry--P\'erot cavity, exhibit great sensitivity not only to the presence but also to the motion of any scattering object within the optical path. We consider the general case of an…

Optics · Physics 2010-07-02 André Xuereb , Tim Freegarde , Peter Horak , Peter Domokos

We propose and implement a quantum procedure for enhancing the sensitivity with which one can determine the phase shift experienced by a weak light beam possessing thermal statistics in passing through an interferometer. Our procedure…

An investigation of the stability of the transfer function of the European Southern Observatory's Very Large Telescope Interferometer has been carried out through observations of Fomalhaut over a wide range in hour angle. No significant…

Chopping observations with a tip-tilt secondary mirror have conventionally been used in ground-based mid-infrared observations. However, it is not practical for next generation large telescopes to have a large tip-tilt mirror that moves at…

We describe the layout and unique features of the focal plane system for MIRI. We begin with the detector array and its readout integrated circuit (combining the amplifier unit cells and the multiplexer), the electronics, and the steps by…

An approach for compensating the influence of the interrogator noises on the readings of interferometric sensors, interrogated by means of spectral interferometry with wavelength tuning is proposed. Both theoretical analysis and a…

Instrumentation and Detectors · Physics 2019-04-30 Nikolai Ushakov , Alexandr Markvart , Leonid Liokumovich