Related papers: ZEPLIN IV: A One Ton Ultimate WIMP Detector
Experimentally have we got what it takes to pursue the direct observation of WIMP interactions down to sensitivities of a few events /100 kg/year? For a Ge target with a low energy threshold (<20 keVr) this corresponds to a WIMP-nucleon…
We study the prospects for detecting Weakly Interacting Massive Particles (WIMPs), in a number of phenomenological scenarios, with a detector composed of a target simultaneously sensitive to both spin-dependent and spin-independent…
We briefly discuss the expected level of supersymmetric dark matter cross-sections as a reference for dark matter detectors. We then discuss the current ZEPLIN II program as a prototype of large liquid Xenon detectors. Cryoarray is a…
The Time Projection Chamber (TPC) has been recognized as a potentially powerful detector for the search of WIMPs by measuring the directions of nuclear recoils, in which the most convincing signature of WIMPs, caused by the Earth's motion…
The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a discrimination method using the different…
LUX-ZEPLIN (LZ) is a dark matter detector expected to obtain world-leading sensitivity to weakly interacting massive particles (WIMPs) interacting via nuclear recoils with a ~7-tonne xenon target mass. This manuscript presents sensitivity…
The report describes the research program on the development of ultra-low-energy germanium detectors, with emphasis on WIMP dark matter searches. A threshold of 100 eV is achieved with a 20 g detector array, providing a unique probe to the…
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of…
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching for WIMP-nucleon interactions. In this paper we describe the data acquisition system used to record the data from ZEPLIN-II and the reduction procedures which…
The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering of target nuclei. The last analysis with an germanium exposure of 397.8 kg-days resulted in zero…
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out…
We study the sensitivity of large-scale xenon detectors to low-energy solar neutrinos, to coherent neutrino-nucleus scattering and to neutrinoless double beta decay. As a concrete example, we consider the xenon part of the proposed DARWIN…
WIMP-nucleon cross sections in the range 10^{-46} - 10^{-44} cm^2 may be probed by a ton-scale experiment with low energy thresholds and excellent discrimination of backgrounds. Because CDMS ZIP detectors are the most proven means of…
A recently proposed dark matter WIMP has only second-order couplings to gauge bosons and itself. As a result, it has small annihilation, scattering, and creation cross-sections, and is consequently consistent with all current experiments…
A new method of searching for dark matter in the form of weakly interacting massive particles (WIMP) has been developed with the direct detection of the low energy nuclear recoils observed in a massive target (ultimately many tons) of ultra…
DARWIN (dark matter wimp search with noble liquids) is a design study for a next-generation, multi-ton dark matter detector in Europe. Liquid argon and/or liquid xenon are the target media for the direct detection of dark matter candidates…
In a recent presentation at the TAUP97 conference about the analysis of data from a NaI(Tl) 100 kg underground detector run at the Gran Sasso Laboratory by the DAMA/NaI group, the speaker concluded there was a hint for a WIMP of mass 60 GeV…
I report recent results and the status of the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory in Minnesota, USA. A blind analysis of data taken by 30 detectors between October 2006 and July 2007 found…
We report first results from the Cryogenic Dark Matter Search (CDMS II) experiment running with its full complement of 30 cryogenic particle detectors at the Soudan Underground Laboratory. This report is based on the analysis of data…
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2…