Related papers: The ROSAT HRI Point Spread Function
Optical spectroscopy has enabled us to identify the optical counterparts to over 200 faint X-ray sources to a flux limit of S_(0.5-2keV)=4x10^-15 erg s^-1 cm^-2 on 5 deep ROSAT fields. Here we present a spectral analysis of all the X-ray…
We present the first in-depth statistical survey of flare source heights observed by RHESSI. Flares were found using a flare-finding algorithm designed to search the 6-10 keV count-rate when RHESSI's full sensitivity was available in order…
We study the angular clustering of point sources in The GMRT (Giant Meter Wave Telescope) Sky Survey (TGSS). The survey at 150 MHz with delta > -53.5 degrees has a sky coverage of 3.6 pi steradians, i.e., 90% of the whole sky. We created…
We present results of inflight calibration of the point spread function (PSF) of the Soft X-ray Telescope (SXT-S) that focuses X-ray onto the pixel array of the Soft X-ray Spectrometer system (SXS). We make a full array image of a…
Using stellar luminosity functions derived from ROSAT data, the contributions of Galactic stars to the diffuse X-ray background are calculated for ROSAT PSPC energy bands. The model follows that of Guillout et al. (1996), but uses ROSAT…
The knowledge of the point spread function (PSF) of the Mikhail Pavlinsky Astronomical Roentgen Telescope - X-ray Concentrator (ART-XC) telescope aboard the Spectrum-Roentgen-Gamma (SRG) observatory plays an especially crucial role in the…
We report a point spread function (PSF) and deconvolution procedure to remove stray light from the Helioseismic and Magnetic Imager (HMI) data. Pre-launch calibration observations, post-launch Venus transit and lunar transit data were used…
The LOFAR Two-metre Sky Survey (LoTSS) will map the complete Northern sky and provide an excellent opportunity to study the distribution and evolution of the large-scale structure of the Universe. We study the completeness of the LoTSS…
The spot size of the x-ray source is a key parameter of a flash-radiography facility, which is usually quoted as an evaluation of the resolving power. The pinhole imaging technique is applied to measure the spot size of the Dragon-I linear…
Incoherently illuminated or luminescent objects give rise to a low-contrast speckle-like pattern when observed through a thin diffusive medium, as such a medium effectively convolves their shape with a speckle-like point spread function…
Planned wide-field weak lensing surveys are expected to reduce the statistical errors on the shear field to unprecedented levels. In contrast, systematic errors like those induced by the convolution with the point spread function (PSF) will…
We examined the anisotropic point spread function (PSF) of Suprime-Cam data utilizing dense star field data. We decomposed the PSF ellipticities into three components, the optical aberration, atmospheric turbulence, and chip-misalignment in…
The X-ray background (XRB) from 0.1 to 7 keV has been studied using high spectral and spatial resolution data from the ASCA SIS and ROSAT PSPC. Analysing both the diffuse background radiation and resolved sources, we have carried out a…
Elongation of the point spread function due to atmospheric dispersion becomes a severe problem for high resolution imaging instruments, if an atmospheric dispersion corrector is not present. In this work we report on a novel technique to…
A method for spatial deconvolution of spectra is presented. It follows the same fundamental principles as the ``MCS image deconvolution algorithm'' (Magain, Courbin, Sohy, 1998) and uses information contained in the spectrum of a reference…
High-fidelity simulated astronomical images are an important tool in developing and measuring the performance of image-processing algorithms, particularly for high precision measurements of cosmic shear -- correlated distortions of images…
An undersampled point spread function may interact with the microstructure of a solid-state detector such that the total flux detected can depend sensitively on where the PSF center falls within a pixel. Such intra-pixel sensitivity…
In preparation of future Multi-Object Spectrographs (MOS) whose one of the major role is to provide an extensive statistical studies of high redshifted galaxies surveyed, the demonstrator Canary has been designed to tackle technical…
Optical microscopy is an essential tool in biology and medicine. Imaging thin, yet non-flat objects in a single shot (without relying on more sophisticated sectioning setups) remains challenging as the shallow depth of field that comes with…
Current state-of-the-art adaptive optics (AO) provides ground-based, diffraction-limited observations with high Strehl ratios (SR). However, a detailed knowledge of the point spread function (PSF) is required to fully exploit the scientific…