Related papers: Stellar models in IR calibration
State-of-the-art (SOTA) semi-supervised learning (SSL) methods have been highly successful in leveraging a mix of labeled and unlabeled data by combining techniques of consistency regularization and pseudo-labeling. During pseudo-labeling,…
As LIGO and Virgo are upgraded, improving calibration systems to keep pace with the anticipated signal-to-noise enhancements will be challenging. We explore here a calibration method that uses astronomical signals, namely inspiral signals…
We describe far infrared observations of early-type galaxies selected from the ISO archive. This rather inhomogeneous sample includes 39 giant elliptical galaxies and 14 S0 (or later) galaxies. These galaxies were observed using a variety…
We are using optical/IR surface brightness fluctuations (SBFs) to validate the latest stellar population synthesis models and to understand the stellar populations of ellipticals. Integrated light and spectra measure only the first moment…
The integrated light of a stellar population, measured through photometric filters that are sensitive to the presence of young stars, is often used to infer the star formation rate (SFR) for that population. However, these techniques rely…
We investigate methods to calibrate the non-common path aberrations at an adaptive optics system having a wavefront-correcting device working at an extremely high resolution (larger than 150x150). We use focal-plane images collected…
Direction dependent calibration of widefield radio interferometers estimates the systematic errors along multiple directions in the sky. This is necessary because with most systematic errors that are caused by effects such as the ionosphere…
Our ability to calibrate current kilometer-scale interferometers can potentially confound the inference of astrophysical signals. Current calibration uncertainties are well described by a Gaussian process. I exploit this description to…
Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in,…
The Infrared Space Observatory (ISO) is used to carry out mid-IR (7 and 15 micron) and far-IR (90 micron) observations of a sample of star-forming sub-mJy radio sources. By selecting the sample at radio wavelengths, one avoids biases due to…
We propose a robust calibration pipeline that optimises the selection of calibration samples for the estimation of calibration parameters that fit the entire scene. We minimise user error by automating the data selection process according…
The response of the Advanced LIGO interferometers is known to vary with time [arXiv:1608.05134]. Accurate calibration of the interferometers must therefore track and compensate for temporal variations in calibration model parameters. These…
We propose and explore the potential of a method to extract high signal-to-noise (S/N) integrated spectra related to physical and/or morphological regions on a 2-dimensional field using Integral Field Spectroscopy (IFS) observations by…
Residual calibration errors are difficult to predict in interferometric radio polarimetry because they depend on the employed observational calibration strategy, encompassing the Stokes vector of the calibrator and parallactic angle…
Current optical interferometers are affected by unknown turbulent phases on each telescope. In the field of radio-interferometry, the self-calibration technique is a powerful tool to process interferometric data with missing phase…
Distance measures on a coherent scale around the sky are required to address the outstanding cosmological problems of the Hubble Constant and of departures from the mean cosmic flow. The correlation between galaxy luminosities and rotation…
High-fidelity spectroscopy presents challenges for both observations and in designing instruments. High-resolution and high-accuracy spectra are required for verifying hydrodynamic stellar atmospheres and for resolving intergalactic…
We investigate the cross-calibration of the Hinode/SOT-SP and SDO/HMI instrument meta-data, specifically the correspondence of the scaling and pointing information. Accurate calibration of these datasets gives the correspondence needed by…
In the context of computer models, calibration is the process of estimating unknown simulator parameters from observational data. Calibration is variously referred to as model fitting, parameter estimation/inference, an inverse problem, and…
Accurate relative spectrophotometry is critical for many science applications. Small wavelength scale residuals in the flux calibration can significantly impact the measurements of weak emission and absorption features in the spectra. Using…