Related papers: Compton scattering sequence reconstruction algorit…
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC…
We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 $\times$ 7.5 $\times$ 15 cm), modular X-ray calorimeter made of…
Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to…
The NeXT mission has been proposed to study high-energy non-thermal phenomena in the universe. The high-energy response of the super mirror will enable us to perform the first sensitive imaging observations up to 80 keV. The focal plane…
The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…
The goal of the Medium Energy Gamma-ray Astronomy (MEGA) telescope is to improve sensitivity at medium gamma-ray energies (0.4-50 MeV) by at least an order of magnitude over that of COMPTEL. This will be achieved with a new compact design…
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy…
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…
A high-brilliance ($\sim10^{24}$~photon.s$^{-1}$.mm$^{-2}$.mrd$^{-2}$/0.1\%) gamma-ray source experiment is currently being planned at Fermilab ($E_\gamma\simeq 1.1$~MeV)~[1]. The source implements a high-repetition-rate inverse Compton…
The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the…
SPECT (Single-photon Emission Computerized Tomography) and PET (Positron Emission Tomography) are essential medical imaging tools, for which the sampling angle number, scan time should be chosen carefully to compromise between image quality…
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and…
We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe…
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…
The Soft Gamma-ray Detector (SGD) on board the NeXT (Japanese future high energy astrophysics mission) is a Compton telescope with narrow field of view (FOV), which utilizes Compton kinematics to enhance its background rejection…
Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier…
There is a growing interest in the science uniquely enabled by observations in the MeV range, particularly in light of multi-messenger astrophysics. The Compton Pair (ComPair) telescope, a prototype of the AMEGO Probe-class concept,…
The detection of photons with energies greater than a few tenths of an MeV, interacting via Compton scattering and/or pair production, faces a number of difficulties. The reconstruction of single-scatter Compton events can only determine…
The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of…
KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer…