Related papers: Michelson Interferometry with the Keck I Telescope
Near-diffraction limited imaging and spectroscopy in the visible on large (8-10 meter) class telescopes has proved to be beyond the capabilities of current adaptive optics technologies, even when using laser guide stars. The need for high…
The application of precision interferometers is generally restricted to expensive and smooth high-quality surfaces. Here, we offer a route to ultimate miniaturization of interferometer by integrating beam splitter, reference mirror and…
FIRST (Fibered Imager foR a Single Telescope instrument) is a post-AO instrument that enables high contrast imaging and spectroscopy at spatial scales below the diffraction limit. FIRST achieves sensitivity and accuracy by a unique…
At present, the principal limitation on the resolution and contrast of astronomical imaging instruments comes from aberrations in the optical path, which may be imposed by the Earth's turbulent atmosphere or by variations in the alignment…
In astronomy or biological imaging, refractive index inhomogeneities of e.g. atmosphere or tissues induce optical aberrations which degrade the desired information hidden behind the medium. A standard approach consists in measuring these…
We theoretically and experimentally study the effect of the coupled-resonator-induced transparency in the Michelson interferometer with the dual-recycled configuration, which is equivalent to the adjustable coupled resonator. The coupling…
High angular resolution images of IRC +10216 taken at various bandpasses within the near-infrared h, k & l bands are presented. The maps have the highest angular resolution yet recovered, and were reconstructed from interferometric…
The number of publications of aperture-synthesis images based on optical long-baseline interferometry measurements has recently increased due to easier access to visible and infrared interferometers. The interferometry technique has now…
The present `state of the art' and the path to future progress in high spatial resolution imaging interferometry is reviewed. The review begins with a treatment of the fundamentals of stellar optical interferometry, the origin, properties,…
I very briefly describe the latest generation near infrared (1-2.5 micron) instruments which are available on, or under development for `large' (D>=3.5 m) telescopes. Most of the imagers under construction are limited to relatively small…
The Keck Planet Imager and Characterizer (KPIC) is an upgrade to the Keck II adaptive optics system enabling high contrast imaging and high-resolution spectroscopic characterization of giant exoplanets in the mid-infrared (2-5 microns). The…
Intensity interferometry permits very long optical baselines and the observation of sub-milliarcsecond structures. Using planned kilometric arrays of air Cherenkov telescopes at short wavelengths, intensity interferometry may increase the…
We present the novel design of microfabricated, silicon-substrate based mirrors for use in cryogenic Fabry-Perot Interferometers (FPIs) for the mid-IR to sub-mm/mm wavelength regime. One side of the silicon substrate will have a…
The Keck Planet Imager and Characterizer (KPIC) is a purpose-built instrument for high-dispersion coronagraphy in the K and L bands on Keck. This instrument will provide the first high resolution (R$>$30,000) spectra of known directly…
Differing from the traditional method of achieving subwavelength interference, we have demonstrated the two-photon subwavelength interference effect of broadband chaotic light in a polarization-selective Michelson interferometer with an…
We present the results of an infrared spectroscopic survey of 23 late-M dwarfs with the NIRSPEC echelle spectrometer on the Keck II telescope. Using telluric lines for wavelength calibration, we are able to achieve measurement precisions of…
We present performance simulations for a proposed visible-light, multi-conjugate adaptive optics system for the 10-meter W. M. Keck I telescope that aims to deliver near diffraction-limited angular resolution at optical wavelengths. Our…
We present a concept of the X-ray imaging system with high angular-resolution and moderate sensitivity. In this concept, a two-dimensional detector, i.e., imager, is put at a slightly out-of-focused position of the focusing mirror, rather…
Here we introduce interferometric devices by combining optical feedback (cavities) with unbiased multiports, which unlike traditional beam dividers, allow light to reflect back out of the port from which it originated. By replacing the…
Source I in the Orion-KL nebula is believed to be the nearest example of a massive star still in the main accretion phase. It is thus one of the best cases for studying the properties of massive protostars to constrain high-mass star…