Related papers: Development of Segmented 4H-SiC LGADs
We designed, produced, and tested RSD (Resistive AC-Coupled Silicon Detectors) devices, an evolution of the standard LGAD (Low-Gain Avalanche Diode) technology where a resistive n-type implant and a coupling dielectric layer have been…
This paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration…
In the field of high-energy particle detection, detectors operating in high-radiation environments primarily face high costs associated with power consumption and cooling systems. Therefore, the development of particle detectors capable of…
AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP)…
In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal…
We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of…
The response of Low Gain Avalanche Diodes (LGADs), a type of thin silicon detector with internal gain, to X-rays of energies between 6-16~keV was characterized at the Stanford Synchrotron Radiation Lightsource (SSRL). The utilized beamline…
Low-Gain Avalanche Diodes are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the Low-Gain…
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well…
With the High-Luminosity Large Hadron Collider (HL-LHC) the number of collisions per bunch crossing increases. To cope with these high rates in the pixel trackers, per-pixel time measurements are required, which implies the need for fast…
Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge in the use of LGADs, studied by several research groups, is…
Silicon sensors with high time resolution can help particle identification in the International Linear Collider (ILC). We are studying Low Gain Avalanche Diodes (LGADs) as a high timing resolution sensor. As a step to develop LGADs, we are…
Low-Gain Avalanche Detectors (LGADs) are the leading 4D sensing technology selected for use in the High Luminosity Large Hadron Collider (HL-LHC). However, their proximity to the interaction point makes them highly susceptible to…
Low Gain Avalanche Detectors(LGADs) is one of the candidate sensing technologies for future 4D-tracking applications and recently have been qualified to be used in the ATLAS and CMS timing detectors for the CERN High Luminosity Large Hadron…
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |{\eta}| < 4 to…
High-energy physics detectors, like Low Gain Avalanche Detectors (LGADs) that will be used as fast timing detectors in the High Luminosity LHC experiments, have to exhibit a significant radiation tolerance. Thereby the impact of radiation…
This contribution reports on characterisation results of a large-area (2$~\mathrm{cm}^2$) small pitch (55$~\mu$m) inverse Low-Gain Avalanche Detector (iLGAD), bonded to a Timepix3 readout chip. The ilGAD sensors were produced by Micron…
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment as part of the Phase-II upgrade for the High Luminosity-Large Hadron Collider (HL-LHC). It will mitigate pile-up effects in the forward region, and…
This paper presents the possibility of using very thin Low Gain Avalanche Diodes (LGAD) ($25 - 50\mu$m thick) as tracking detector at future hadron colliders, where particle fluence will be above $10^{16}\; n_{eq}/cm^2$. In the present…
Low-Gain Avalanche Diodes (LGADs) provide moderate internal gain and time resolutions of a few tens of picoseconds, making them a key technology for ultrafast timing in high-energy physics and beyond. However, both their gain and timing…