Computed tomography (CT) is widely used in screening, diagnosis, and image-guided therapy for both clinical and research purposes. Since CT involves ionizing radiation, an overarching thrust of related technical research is development of…

Image and Video Processing · Electrical Eng. & Systems 2019-06-25 Chenyu You , Guang Li , Yi Zhang , Xiaoliu Zhang , Hongming Shan , Shenghong Ju , Zhen Zhao , Zhuiyang Zhang , Wenxiang Cong , Michael W. Vannier , Punam K. Saha , Ge Wang

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Accurate targeting is critical for the effectiveness of transcranial focused ultrasound (tFUS) neuromodulation. While CT provides accurate skull acoustic properties, its ionizing radiation and poor soft tissue contrast limit clinical…

Medical Physics · Physics 2025-07-14 Hengyu Gao , Shaodong Ding , Ziyang Liu , Jiefu Zhang , Bolun Li , Zhiwu An , Li Wang , Jing Jing , Tao Liu , Yubo Fan , Zhongtao Hu

MR-only radiotherapy treatment planning requires accurate MR-to-CT synthesis. Current deep learning methods for MR-to-CT synthesis depend on pairwise aligned MR and CT training images of the same patient. However, misalignment between…

Computer Vision and Pattern Recognition · Computer Science 2017-08-04 Jelmer M. Wolterink , Anna M. Dinkla , Mark H. F. Savenije , Peter R. Seevinck , Cornelis A. T. van den Berg , Ivana Isgum

The translation from Magnetic resonance imaging (MRI) to Computed tomography (CT) has been proposed as an effective solution to facilitate MRI-only clinical workflows while limiting exposure to ionizing radiation. Although numerous…

Computer Vision and Pattern Recognition · Computer Science 2026-03-17 Alessandro Pesci , Valerio Guarrasi , Marco Alì , Isabella Castiglioni , Paolo Soda

Computed tomography (CT) is critical for various clinical applications, e.g., radiotherapy treatment planning and also PET attenuation correction. However, CT exposes radiation during acquisition, which may cause side effects to patients.…

Computer Vision and Pattern Recognition · Computer Science 2016-12-19 Dong Nie , Roger Trullo , Caroline Petitjean , Su Ruan , Dinggang Shen

Diversity in data is critical for the successful training of deep learning models. Leveraged by a recurrent generative adversarial network, we propose the CT-SGAN model that generates large-scale 3D synthetic CT-scan volumes ($\geq…

Image and Video Processing · Electrical Eng. & Systems 2021-11-08 Ahmad Pesaranghader , Yiping Wang , Mohammad Havaei

The Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation…

Medical Physics · Physics 2025-03-11 Gary Y Ge , Charles M Weaver , Jie Zhang

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging…

Medical Physics · Physics 2010-04-13 Xun Jia , Yifei Lou , John Lewis , Ruijiang Li , Xuejun Gu , Chunhua Men , William Y. Song , Steve B. Jiang

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

Computer Vision and Pattern Recognition · Computer Science 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

Computed tomography (CT) equivalent information is needed for attenuation correction in PET imaging and for dose planning in radiotherapy. Prior work has shown that Gaussian mixture models can be used to generate a substitute CT (s-CT)…

Applications · Statistics 2016-09-29 Anders Hildeman , David Bolin , Jonas Wallin , Adam Johansson , Tufve Nyholm , Thomas Asklund , Jun Yu

Objective: Four-dimensional computed tomography (4DCT) imaging consists in reconstructing a CT acquisition into multiple phases to track internal organ and tumor motion. It is commonly used in radiotherapy treatment planning to establish…

Computer Vision and Pattern Recognition · Computer Science 2024-04-02 Yi-Heng Cao , Vincent Bourbonne , François Lucia , Ulrike Schick , Julien Bert , Vincent Jaouen , Dimitris Visvikis

Defective and inconsistent responses in CT detectors can cause ring and streak artifacts in the reconstructed images, making them unusable for clinical purposes. In recent years, several ring artifact reduction solutions have been proposed…

Computer Vision and Pattern Recognition · Computer Science 2026-02-13 Hongxu Yang , Levente Lippenszky , Edina Timko , Gopal Avinash

Medical imaging is vital in computer assisted intervention. Particularly cone beam computed tomography (CBCT) with defacto real time and mobility capabilities plays an important role. However, CBCT images often suffer from artifacts, which…

Computer Vision and Pattern Recognition · Computer Science 2024-07-23 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

Image reconstruction from insufficient data is common in computed tomography (CT), e.g., image reconstruction from truncated data, limited-angle data and sparse-view data. Deep learning has achieved impressive results in this field.…

Image and Video Processing · Electrical Eng. & Systems 2020-05-21 Yixing Huang , Alexander Preuhs , Michael Manhart , Guenter Lauritsch , Andreas Maier

Transcranial focused ultrasound (tFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively and often under MRI guidance. CT imaging is used to estimate the acoustic properties that vary…

Image and Video Processing · Electrical Eng. & Systems 2022-10-27 Han Liu , Michelle K. Sigona , Thomas J. Manuel , Li Min Chen , Benoit M. Dawant , Charles F. Caskey

Scanning tunnelling microscopy (STM) enables atomic-resolution imaging and atom manipulation, but its utility is often limited by tip degradation and slow serial data acquisition. Fabrication adds another layer of complexity since the tip…

Computer Vision and Pattern Recognition · Computer Science 2025-10-31 Nikola L. Kolev , Tommaso Rodani , Neil J. Curson , Taylor J. Z. Stock , Alberto Cazzaniga

Magnetic resonance imaging (MRI) provides varying tissue contrast images of internal organs based on a strong magnetic field. Despite the non-invasive advantage of MRI in frequent imaging, the low contrast MR images in the target area make…

Image and Video Processing · Electrical Eng. & Systems 2020-06-11 Mohammad Hamghalam , Baiying Lei , Tianfu Wang

This paper proposes a novel, unsupervised super-resolution (SR) approach for performing the SR of a clinical CT into the resolution level of a micro CT ($\mu$CT). The precise non-invasive diagnosis of lung cancer typically utilizes clinical…

Image and Video Processing · Electrical Eng. & Systems 2020-11-22 Tong Zheng , Hirohisa Oda , Masahiro Oda , Shota Nakamura , Masaki Mori , Hirotsugu Takabatake , Hiroshi Natori , Kensaku Mori

In Europe the 20% of the CT scans cover the thoracic region. The acquired images contain information about the cardiovascular system that often remains latent due to the lack of contrast in the cardiac area. On the other hand, the contrast…

Computer Vision and Pattern Recognition · Computer Science 2018-07-06 Gianmarco Santini , Lorena M. Zumbo , Nicola Martini , Gabriele Valvano , Andrea Leo , Andrea Ripoli , Francesco Avogliero , Dante Chiappino , Daniele Della Latta