We propose a novel optimization model for volumetric modulated arc therapy (VMAT) planning that directly optimizes deliverable leaf trajectories in the treatment plan optimization problem, and eliminates the need for a separate…

Medical Physics · Physics 2014-03-05 Dávid Papp , Jan Unkelbach

In recent years, volumetric modulated arc therapy (VMAT) has been becoming a more and more important radiation technique widely used in clinical application for cancer treatment. One of the key problems in VMAT is treatment plan…

Medical Physics · Physics 2016-01-06 Yu Yang , Bin Dong , Zaiwen Wen

Background and Purpose: Increasing the number of arcs in volumetric modulated arc therapy (VMAT) allows for better intensity modulation and may improve plan quality. However, this leads to longer delivery times, which may cause patient…

Medical Physics · Physics 2025-10-31 Nathan Torelli , Madalyne Day , Jan Unkelbach

Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex…

Medical Physics · Physics 2015-05-19 Chunhua Men , H. Edwin Romeijn , Xun Jia , Steve B. Jiang

This study evaluates dynamic conformal arc (DCA) therapy as an alternative to volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT) of lung cancer. The rationale for DCA is lower geometric complexity and…

Medical Physics · Physics 2019-05-07 Rasmus Bokrantz , Minna Wedenberg , Peter Sandwall

Temporally modulated pulsed radiotherapy (TMPRT) delivers conventional fraction doses of radiation using temporally separated pulses of low doses (<30 cGy) yielding fraction-effective dose rates of around 6.7 cGy/min with the goal to…

Medical Physics · Physics 2026-01-13 Christian Velten , Adam Bayliss , Jiayi Huang , Wolfgang A. Tomé

A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are…

Medical Physics · Physics 2019-09-04 Rodney D. Wiersma , Xinmin Liu

Purpose: To verify dose delivery and quality assurance of volumetric modulated arc therapy (VMAT) for head and neck cancer. Method: The Imaging and Radiation Oncology Core Houston (IROC-H) head and neck phantom with thermo- luminescent…

Volumetric Modulated Arc Therapy (VMAT) is a cornerstone of modern radiation therapy, enabling highly conformal tumor irradiation and healthy-tissue sparing. Yet, its planning solves inverse and nested optimization for multi-leaf…

Computer Vision and Pattern Recognition · Computer Science 2026-05-14 Isabella Poles , Simon Arberet , Riqiang Gao , Martin Kraus , Marco D. Santambrogio , Florin C. Ghesu , Ali Kamen , Dorin Comaniciu

Radiotherapy (RT) is a critical cancer treatment, with volumetric modulated arc therapy (VMAT) being a commonly used technique that enhances dose conformity by dynamically adjusting multileaf collimator (MLC) positions and monitor units…

Medical Physics · Physics 2025-06-26 Stefanos Achlatis , Efstratios Gavves , Jan-Jakob Sonke

In this article we provide a method to generate the trade-off between delivery time and fluence map matching quality for volumetric modulated arc therapy (VMAT). At the heart of our method lies a mathematical programming model that, for a…

Medical Physics · Physics 2017-03-08 Marleen Balvert , David Craft

The purpose of this study is to give an exact formulation of optimization of volumetric-modulated arc therapy (VMAT) with sliding-window delivery, and to investigate the plan quality effects of decreasing the number of sliding-window sweeps…

Medical Physics · Physics 2018-10-23 Lovisa Engberg , Anders Forsgren

Purpose: To make the planning of volumetric modulated arc therapy (VMAT) faster and to explore the tradeoffs between planning objectives and delivery efficiency. Methods: A convex multicriteria dose optimization problem is solved for an…

Medical Physics · Physics 2015-05-28 David Craft , Dualta McQuaid , Jeremiah Wala , Wei Chen , Ehsan Salari , Thomas Bortfeld

We developed a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources efficiently and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries. Our IMPAT…

Purpose: To improve the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. Methods and materials: A high-quality initial plan is…

Medical Physics · Physics 2015-06-05 Jeremiah Wala , Ehsan Salari , Wei Chen , David Craft

Volumetric Modulated Arc Therapy (VMAT) revolutionizes cancer treatment by precisely delivering radiation while sparing healthy tissues. Fluence maps generation, crucial in VMAT planning, traditionally involves complex and iterative, and…

Image and Video Processing · Electrical Eng. & Systems 2025-02-06 Simon Arberet , Florin C. Ghesu , Riqiang Gao , Martin Kraus , Jonathan Sackett , Esa Kuusela , Ali Kamen

A new strategy for radiation therapy dosimetry planning (RTDP) used to reduce dose estimation errors due to respiratory motion in breast treatment was illustrated and evaluated in this study. On CT data set acquired for breast treatment,…

Medical Physics · Physics 2021-10-20 Mazen Moussallem , Pauline Harb , Hanane Rima , Zeina Al Kattar , Saad Ayoubi

Background: The deep inspiration breath hold technique (DIBH) is widely used for left-sided breast radiotherapy (RT), in order to reduce the dose to the heart and the risk of cardiotoxicity. The volumetric arc therapy (VMAT) technique…

Medical Physics · Physics 2019-03-14 C. Tamburella , G. Guibert , O. Santa Cruz , P. Weber , P. Tsousou

Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target…

This study investigates the applicability of 3D dose predictions from a model trained on one modality to a cross-modality automated planning workflow. Additionally, we explore the impact of integrating a multi-criteria optimizer on adapting…

Medical Physics · Physics 2024-02-26 Gregory Szalkowski , Xuanang Xu , Shiva Das , Pew-Thian Yap , Jun Lian