Related papers: Amplitude Modulation Noise Suppression of Dynamic …
Density changes in the atmosphere produce a fluctuating gravity field that affect gravity strainmeters or gravity gradiometers used for the detection of gravitational-waves and for geophysical applications. This work addresses the impact of…
We present a method to suppress the potential roughness of a wire-based, magnetic atom guide: modulating the wire current at a few tens of kHz, the potential roughness, which is proportional to the wire current, averages to zero. Using…
We introduce a novel measurement method for the phase noise measurement of optical amplifiers, topologically similar to the Heterodyne Mach-Zehnder Interferometer but governed by different principles, and we report on the measurement of a…
The effects of residual amplitude modulation (RAM) in laser interferometers using heterodyne sensing can be substantial and difficult to mitigate. In this work, we analyze the effects of RAM on a complex laser interferometer used for…
We demonstrate a proof-of-principle of direct Earth gravity gradient measurement with an atom interferometer-based gravity gradiomter using a single proof mass of cold 87 rubidium atoms. The atomic gradiometer is implemented in the…
Advanced gravitational wave interferometric detectors will operate at their design sensitivity with nearly 1MW of laser power stored in the arm cavities. Such large power may lead to the uncontrolled growth of acoustic modes in the test…
We introduce modeling and simulation of the noise properties associated with types of modal oscillations induced by scaling the asymmetric gain suppression (AGS) in multimode semiconductor lasers. The study is based on numerical integration…
We focus on the fact that light-pulse atom interferometers measure the atoms' acceleration with only three data points per drop. As a result, the measured effect of the gravity gradient is systematically larger than the true one, an error…
Atom interferometers are very sensitive to accelerations and rotations. This property, which has some very interesting applications, induces a deleterious phase noise due to the seismic noise of the laboratory and this phase noise is…
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60…
Absolute gravimeters (AG) are used in geodesy, geophysics, and physics for a wide spectrum of applications. Stable gravimetric measurements over timescales from several days to decades are required to provide relevant insight into…
Optical fiber modal noise is a limiting factor for high precision spectroscopy signal-to-noise in the near-infrared and visible. Unabated, especially when using highly coherent light sources for wavelength calibration, modal noise can…
Robust gauge conditions are critically important to the stability and accuracy of numerical relativity (NR) simulations involving compact objects. Most of the NR community use the highly robust---though decade-old---moving-puncture (MP)…
To understand the origin of nuclear ($\lesssim$ 100 pc) millimeter-wave (mm-wave) continuum emission in active galactic nuclei (AGNs), we systematically analyzed sub-arcsec resolution Band-6 (211-275 GHz) ALMA data of 98 nearby AGNs ($z <$…
We present a horizontal gravity gradiometer atom interferometer for precision gravitational tests. The horizontal configuration is superior for maximizing the inertial signal in the atom interferometer from a nearby proof mass. In our…
The high inertial sensitivity of atom interferometers has been used to build accelerometers and gyrometers but this sensitivity makes these interferometers very sensitive to the laboratory seismic noise. This seismic noise induces a phase…
We describe the characterization and removal of noise present in the Inertial Measurement Unit (IMU) MPU-6050. This IMU was initially used in an attitude sensor (AS) developed in-house, and subsequently implemented in a pointing and…
Active noise control (ANC) has been widely utilized to reduce unwanted environmental noise. The primary objective of ANC is to generate an anti-noise with the same amplitude but the opposite phase of the primary noise using the secondary…
To date, frequency-dependent squeezed light has been used to reduce quantum noise in interferometric gravitational wave detectors by 6.1 dB (a factor of two). Future upgrades and detectors aim to both reduce quantum noise by 10 dB (a factor…
We investigate a new experimental possibility of measuring the Newtonian gravitational constant $G$ by using the weak measurement. Amplification via weak measurement is one of the interesting phenomena of quantum mechanics. In this letter,…