Concurrent TMS-fMRI involves administrating TMS while subjects are inside an MRI scanner and allows the study of the effects of neurostimulation on simultaneous brain activity. Despite its high promise, the technique has proven challenging…
Deep-learning-based brain magnetic resonance imaging (MRI) reconstruction methods have the potential to accelerate the MRI acquisition process. Nevertheless, the scientific community lacks appropriate benchmarks to assess MRI reconstruction…
Magnetic Particle Imaging (MPI) is a novel and versatile imaging modality developing towards human application. When up-scaling to human size, the sensitivity of the systems naturally drops as the coil sensitivity depends on the bore…
Anatomy-specific RF receive coil arrays routinely adopted in magnetic resonance imaging (MRI) for signal acquisition, are commonly burdened by their bulky, fixed, and rigid configurations, which may impose patient discomfort, bothersome…
In this work a mu=-1 metamaterial (MM) lens for magnetic resonance imaging (MRI) is demonstrated. MRI uses surface coils to detect the radiofrequency(RF) energy absorbed and emitted by the nuclear spins in the imaged object. The proposed MM…
In Magnetic Resonance Imaging (MRI), to achieve sufficient Signal to Noise Ratio (SNR), the electrical performance of the RF coil is critical. We developed a device (microcoil) based on the original concept of monolithic resonator. This…
A high NMR detection sensitivity is indispensable when dealing with mass and volume-limited samples, or whenever a high spatial resolution is required. The use of miniaturised RF coils is a proven way to increase sensitivity, but may be…
Current magnetic resonance imaging (MRI) requires the subject to remain stationary to limit motion artifacts and avoid unwanted field-induced brain stimulation. However, imaging during large-scale motion could enable studies in which motion…
Magnetic resonance imaging systems rely on signal detection via radiofrequency coil arrays which, ideally, need to provide both bendability and form-fitting stretchability to conform to the imaging volume. However, most commercial coils are…
Magnetic resonance imaging (MRI) is a potent diagnostic tool, but suffers from long examination times. To accelerate the process, modern MRI machines typically utilize multiple coils that acquire sub-sampled data in parallel. Data-driven…
Magnetic Resonance Imaging (MRI) stands as a powerful modality in clinical diagnosis. However, it is known that MRI faces challenges such as long acquisition time and vulnerability to motion-induced artifacts. Despite the success of many…
The need for affordable and appropriate medical technologies for developing countries continue to rise as challenges such as inadequate energy supply, limited technical expertise and poor infrastructure persists. Low-field MRI is a…
Leveraging the potential of low-field Magnetic Resonance Imaging (MRI), our study introduces the multimodal surface RF coil, a design tailored to overcome the limitations of conventional coils in this context. The inherent challenges of…
Transcranial magnetic stimulation (TMS) is a popular method for the noninvasive stimulation of neurons in the brain. It has become a standard instrument in experimental brain research and is approved for a range of diagnostic and…
Magnetic Resonance Imaging (MRI) is a noninvasive imaging technique that provides excellent soft-tissue contrast without using ionizing radiation. MRI's clinical application may be limited by long data acquisition time; therefore, MR image…
Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported…
Modern MRI scanners utilize one or more arrays of small receive-only coils to collect k-space data. The sensitivity maps of the coils, when estimated using traditional methods, differ from the true sensitivity maps, which are generally…
Modern magnetic resonance imaging (MRI) relies on application-specific multi-channel receive coils to achieve high performance, but these coils are typically costly, rigid, and difficult to generalize across anatomies. Recent wireless,…
It is well known that magnetic resonance imaging (MRI) at 7 Tesla (7T) and higher magnets can provide much better signal sensitivity compared with lower field strengths. However, variety of commercially available ultra-high-field MRI coils…
Purpose: To develop and evaluate a wearable wireless resonator glasses design that enhances eye MRI signal-to-noise ratio (SNR) without compromising whole-brain image quality at 7 T. Methods: The device integrates two detunable LC loop…