Related papers: On Optimizing Electrode Configuration for Wrist-Wo…
Electromyography (EMG) has been explored as an HCI input modality following a long history of success for prosthesis control. While EMG has the potential to address a range of hands-free interaction needs, it has yet to be widely accepted…
A central challenge in building robotic prostheses is the creation of a sensor-based system able to read physiological signals from the lower limb and instruct a robotic hand to perform various tasks. Existing systems typically perform…
Electromyography (EMG) data has been extensively adopted as an intuitive interface for instructing human-robot collaboration. A major challenge of the real-time detection of human grasp intent is the identification of dynamic EMG from hand…
Surface electromyography (sEMG) is a widely employed bio-signal that captures human muscle activity via electrodes placed on the skin. Several studies have proposed methods to remove sEMG contaminants, as non-invasive measurements render…
Microsurgery is a particularly impactful yet challenging form of surgery. Robot assisted microsurgery has the potential to improve surgical dexterity and enable precise operation on such small scales in ways not previously possible.…
Surface electromyography (sEMG) sensors are widely used in human-computer interaction, yet the failure of a single sensor can compromise system usability. We propose a methodological framework for implementing a fail-safe mechanism in…
Extraction of the movement-related high-gamma (80 - 160 Hz) in electroencephalogram (EEG) from traumatic brain injury (TBI) patients who have had hemicraniectomies, remains challenging due to a confounding bandwidth overlap with surface…
Decoding the activity of the nervous system is a critical challenge in neuroscience and neural interfacing. In this study, we present a neuromuscular recording system that enables large-scale sampling of muscle activity using microelectrode…
In this paper, we present electromyography analysis of human activity - database 1 (EMAHA-DB1), a novel dataset of multi-channel surface electromyography (sEMG) signals to evaluate the activities of daily living (ADL). The dataset is…
We explore surface electromyography (sEMG) as a non-invasive input modality for mapping muscle activity to keyboard inputs, targeting immersive typing in next-generation human-computer interaction (HCI). This is especially relevant for…
The Electromyography (EMG) signal is the electrical activity produced by cells of skeletal muscles in order to provide a movement. The non-invasive prosthetic hand works with several electrodes, placed on the stump of an amputee, that…
Myoelectric pattern recognition is one of the important aspects in the design of the control strategy for various applications including upper-limb prostheses and bio-robotic hand movement systems. The current work has proposed an approach…
In this paper we study the problem of improving human hand pose sensing device performance by exploiting the knowledge on how humans most frequently use their hands in grasping tasks. In a companion paper we studied the problem of…
Objective: The main goal of the athletes who undergo anterior cruciate ligament reconstruction (ACLR) surgery is a successful return-to-sport. At this stage, identifying muscular deficits becomes important. Hence, in this study, three…
Continuous estimation of high-dimensional finger kinematics from forearm surface electromyography (EMG) could enable natural control for hand prostheses, AR/XR interfaces, and teleoperation. However, the complexity of human hand gestures…
Retargeting human motion to robot poses is a practical approach for teleoperating bimanual humanoid robot arms, but existing methods can be suboptimal and slow, often causing undesirable motion or latency. This is due to optimizing to match…
Objective: For transradial amputees, robotic prosthetic hands promise to regain the capability to perform daily living activities. Current control methods based on physiological signals such as electromyography (EMG) are prone to yielding…
This paper presents a comprehensive analytical and simulation-based study of curved electrode geometries for enhancing the sensitivity of MEMS capacitive accelerometers. Expressions for the capacitance between a planar movable electrode and…
Surface electromyography (sEMG) is a technology to assess muscle activation, which is an important component in applications related to diagnosis, treatment, progression assessment, and rehabilitation of specific individuals' conditions.…
Surface electromyography (sEMG) signals show promise for effective human-machine interfaces, particularly in rehabilitation and prosthetics. However, challenges remain in developing systems that respond quickly to user intent, produce…