Related papers: Optimisation of calibration sources for global 21-…
To achieve the sensitivity required to detect signals from neutral hydrogen from the Cosmic Dawn and Epoch of Reionisation it is critical to have a well-calibrated instrument which has a stable calibration over the course of the…
Observations of the 21-cm line from primordial hydrogen promise to be one of the best tools to study the early epochs of the Universe: the Dark Ages, the Cosmic Dawn, and the subsequent Epoch of Reionization. In 2018, the EDGES experiment…
Recent experiments in cosmology, particularly those aimed at detecting the faint, redshifted, global 21 cm hydrogen line (depth < ~200 mK, z > 7.5), have imposed stringent new requirements on radiometer calibration. In this work, we present…
Radiometer experiments to detect 21-cm Hydrogen line emission from the Cosmic Dawn and Epoch of Reionization rely upon precise absolute calibration. During calibration, noise generated by amplifiers within the radiometer receiver must be…
The redshifted 21-cm signal from the Cosmic Dawn and Epoch of Reionization carries invaluable information about the cosmology and astrophysics of the early Universe. Analyzing data from a sky-averaged 21-cm signal experiment requires…
Following the reported detection of an absorption profile associated with the 21~cm sky-averaged signal from the Cosmic Dawn by the EDGES experiment in 2018, a number of experiments have been set up to verify this result. This paper…
The Epoch of Reionization (EoR) and Cosmic Dawn (CD) are pivotal stages during the first billion years of the universe, exerting a significant influence on the development of cosmic structure. The detection of the redshifted 21-cm signal…
The 21-cm signal of neutral hydrogen is a sensitive probe of the Epoch of Reionization (EoR) and Cosmic Dawn. Currently operating radio telescopes have ushered in a data-driven era of 21-cm cosmology, providing the first constraints on the…
Detection of millikelvin-level signals from the 'Cosmic Dawn' requires an unprecedented level of sensitivity and systematic calibration. We report the theory behind a novel calibration algorithm developed from the formalism introduced by…
Radio-interferometric arrays require very precise calibration to detect the Epoch of Reionization 21-cm signal. A remarkably complete and accurate sky model is therefore needed in the patches of the sky used to perform the calibration.…
The 21-cm signal of neutral hydrogen - emitted during the Epoch of Reionization - promises to be an important source of information for the study of the infant universe. However, its detection is impossible without sufficient mitigation of…
We detail the the REACH radiometric system designed to enable measurements of the 21-cm neutral hydrogen line. Included is the radiometer architecture and end-to-end system simulations as well as a discussion of the challenges intrinsic to…
We report on the MIT Epoch of Reionization (MITEoR) experiment, a pathfinder low-frequency radio interferometer whose goal is to test technologies that improve the calibration precision and reduce the cost of the high-sensitivity 3D mapping…
Due to the large dynamic ranges involved with separating the cosmological 21-cm signal from the Cosmic Dawn from galactic foregrounds, a well-calibrated instrument is essential to avoid biases from instrumental systematics. In this paper we…
Observation of the redshifted 21-cm signal from Cosmic Dawn and Epoch of Reionization is a challenging endeavor in observational cosmology. Presence of orders of magnitude brighter astrophysical foregrounds and various instrumental…
The global 21 cm signal from Cosmic Dawn (CD) and the Epoch of Reionization (EoR), at redshifts $z \sim 6-30$, probes the nature of first sources of radiation as well as physics of the Inter-Galactic Medium (IGM). Given that the signal is…
The redshifted 21 cm line signal is a powerful probe of the cosmic dawn and the epoch of reionization. The global spectrum can potentially be detected with a single antenna and spectrometer. However, this measurement requires an extremely…
We discuss absolute calibration strategies for Phase I of the Hydrogen Epoch of Reionization Array (HERA), which aims to measure the cosmological 21 cm signal from the Epoch of Reionization (EoR). HERA is a drift-scan array with a 10 degree…
Measurement of the global 21-cm signal during Cosmic Dawn (CD) and the Epoch of Reionization (EoR) is made difficult by bright foreground emission which is 2-5 orders of magnitude larger than the expected signal. Fitting for a…
21 cm Epoch of Reionization observations promise to transform our understanding of galaxy formation, but these observations are impossible without unprecedented levels of instrument calibration. We present end-to-end simulations of a full…