English
Related papers

Related papers: Using Fast Reading Current Integrator for Advanced…

200 papers

The proposed Electron-Ion Collider (EIC) will utilize high-luminosity high-energy electron+proton ($e+p$) and electron+nucleus ($e+A$) collisions to solve several fundamental questions including searching for gluon saturation and studying…

In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…

A wideband phase comparator for precise measurements of phase difference of high current shunts has been developed at INRIM. The two-input digital phase detector is realized with a precision wideband digitizer connected through a pair of…

Instrumentation and Detectors · Physics 2015-05-30 Umberto Pogliano , Bruno Trinchera , Danilo Serazio

Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world.…

In accelerators, ion beams are often accelerated using electrostatic accelerating tubes. This paper reports on a method to improve the beam transport efficiency without adding new components to the beam transport system. High beam currents…

The speed of quantum gates and measurements is a decisive factor for the overall fidelity of quantum protocols when performed on physical qubits with finite coherence time. Reducing the time required to distinguish qubit states with high…

Accurate range verification of carbon ion beams is critical for the precision and safety of charged particle radiotherapy. In this study, we evaluated the feasibility of using a parallel-plate ionization chamber for real-time, time-based…

A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The…

Accelerator Physics · Physics 2018-05-23 P. Thieberger , D. Gassner , R. Hulsart , R. Michnoff , T. Miller , M. Minty , Z. Sorrell , A. Bartnik

Fast ionic conduction is a defining property of solid electrolytes for all-solid-state batteries. Previous studies have suggested that liquid-like cation motion associated with fast ionic transport can disrupt crystalline symmetry, thereby…

Beam measurement is very important for accelerators. With the development of analog-to-digital conversion techniques, digital beam measurement becomes a research hot spot. IQ (In-phase & Quadrature-phase) analysis based method is an…

Accelerator Physics · Physics 2016-08-03 Lei Zhao , Linsong Zhan , Xingshun Gao , Shubin Liu , Qi An

Joint communication and sensing applications require devices that can analyze multiple electromagnetic waves and process them in real time directly in the analog domain. In optics, the growing maturity of photonic integrated platforms…

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

We present a high-throughput computational screening for fast lithium-ion conductors to identify promising materials for application in all solid-state electrolytes. Starting from more than 30,000 Li-containing experimental structures…

Materials Science · Physics 2026-01-07 Tushar Singh Thakur , Loris Ercole , Nicola Marzari

The ability to use coherent light for material science and applications is directly linked to our ability to measure short optical pulses. While free-space optical methods are well-established, achieving this on a chip would offer the…

In the strive for scalable quantum processors, significant effort is being devoted to the development of cryogenic classical hardware for the control and readout of a growing number of qubits. Here we report on a cryogenic circuit…

Quantum Physics · Physics 2021-02-10 L. Le Guevel , G. Billiot , S. De Franceschi , A. Morel , X. Jehl , A. G. M. Jansen , G. Pillonnet

Detectors planned for use at the Large Hadron Collider will operate in a radiation field produced by beam collisions. To predict the radiation damage to the components of the detectors, prototype devices are irradiated at test beam…

Instrumentation and Detectors · Physics 2015-06-17 Prabhakar Palni , Martin Hoeferkamp , Aaron Taylor , Sandip Vora , Haley McDuff , Qufei Gu , Sally Seidel

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the…

Instrumentation and Detectors · Physics 2019-08-14 C. Schill

A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Fermilab Tevatron collider is described. It is based on the signal from a single beam-position monitor located in a region of the ring…

Accelerator Physics · Physics 2013-12-19 G. Stancari , A. Valishev , S. M. White

Radiation hard helium gas ionization chambers capable of operating in vacuum at temperatures ranging from 5K to 350K have been designed, fabricated and tested and will be used inside the cryostats at Fermilab's Superconducting…

Accelerator Physics · Physics 2012-10-01 A. Warner , J. Wu

Fast beam collinear laser spectroscopy is the established method to investigate nuclear ground state properties such as the spin, the electromagnetic moments, and the charge radius of exotic nuclei. These are extracted with high precision…