Related papers: Development of a one-dimensional position sensitiv…
We present commissioning data for the POLISH instrument obtained on the Hale 5-m telescope. The goal of this high precision polarimeter is to constrain orbital inclination of high mass X-ray binaries and to therefore obtain independent mass…
The NeXT mission has been proposed to study high-energy non-thermal phenomena in the universe. The high-energy response of the super mirror will enable us to perform the first sensitive imaging observations up to 80 keV. The focal plane…
The motivation of the current R&D project is based upon the requirements of the JEDI international collaboration aiming to measure Electric Dipole Moments (EDMs) of charged particles in storage rings. One of the most important elements of…
Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…
The energy range above 60 keV is important for the study of many open problems in high energy astrophysics such as the role of Inverse Compton with respect to synchrotron or thermal processes in GRBs, non thermal mechanisms in SNR, the…
Exciton-polaritons provide a versatile platform for the study of a wide range of phenomena, including polariton lasers, topological polaritons, and bosonic condensation. Transition metal dichalcogenide monolayers host excitons with large…
Recent advancements in particle physics demand pixel detectors that can withstand increased luminosity in the future collider experiments. In response, MALTA, a novel monolithic active pixel detector, has been developed with a cutting-edge…
Cen X-3 is the first X-ray pulsar discovered 50 years ago. Radiation from such objects is expected to be highly polarized due to birefringence of plasma and vacuum associated with propagation of photons in presence of the strong magnetic…
This paper describes the design and construction of a Cherenkov detector conceived with regard to high energy Compton polarimeters for the International Linear Collider, where beam diagnostic systems of unprecedented precision must…
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction.…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
Noble liquid detectors have become an attractive option for exploring physics beyond the standard model. Current experiments are using these detectors to search for dark matter interactions, neutrinoless double beta decay, and other…
High energy polarization can be an indication of geometry, orientation, and other physical phenomena for a variety of sources, but has heretofore been a virtually unmeasured phenomenon. PoGOLite is a balloon-borne instrument intended to…
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson…
POLAR-2 is a dedicated gamma-ray polarimeter currently foreseen to be launched towards the China Space Station around 2027. The design of the detector is based on the legacy of its predecessor mission POLAR which was launched in 2016.…
The Imaging X-ray Polarimetry Explorer (IXPE) measured with high significance the X-ray polarization of the brightest Z-source Scorpius X-1, resulting in the nominal 2-8 keV energy band in a polarization degree of 1.0(0.2)% and a…
We have developed a terahertz radiation detector that measures both the amplitude and polarization of the electric field as a function of time. The device is a three-contact photoconductive receiver designed so that two orthogonal…
Recently CMOS (complementary metal-oxide semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray…
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission…
This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously…