Related papers: Development of a one-dimensional position sensitiv…
We report on an X-ray polarimetric observation of the high-mass X-ray binary LMC X-1 in the high/soft state, obtained by the Imaging X-ray Polarimetry Explorer (IXPE) in October 2022. The measured polarization is below the minimum…
We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray…
POLAR is a space-borne hard X-ray Compton polarimeter built by a collaboration of institutes from Switzerland, China and Poland. Precise detection of the polarization can be a powerful tool to unveil emission mechanisms of e.g. Gamma-Ray…
XPOL, the first correlation polarimeter at a large millimeter telescope, uses a flexible digital correlator to measure all four Stokes parameters simultaneously, i.e. the total power I, the linear polarization components Q and U, and the…
Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be…
X-rays astrophysical sources have been almost exclusively characterized through imaging, spectroscopy and timing analysis. Nevertheless, more observational parameters are needed because some radiation mechanisms present in neutrons stars or…
Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to…
We describe the current status of the design and development of a Thomson X-ray polarimeter suitable for a small satellite mission. Currently we are considering two detector geometries, one using rectangular detectors placed on four sides…
We report on the development of a large-volume, wide field-of-view time projection chamber (TPC) for X-ray polarimetry, featuring a triple-GEM amplification stage and optical readout. Originally developed within the CYGNO program for…
PoGOLite is a hard X-ray polarimeter operating in the 25-100 keV energy band. The instrument design is optimised for the observation of compact astrophysical sources. Observations are conducted from a stabilised stratospheric balloon…
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric…
The Low Energy Polarization Detector (LPD) is a key component of the next-generation large-scale Gamma-Ray Burst polarimeter, POLAR-2. It is designed for polarization observations of transient sources in the soft X-ray energy range with a…
The on-chip measurement of polarization states plays an increasingly crucial role in modern sensing and imaging applications. While high-performance monolithic linearly polarized photodetectors have been extensively studied, integrated…
The capability of NuSTAR to detect polarization in the Compton scattering regime (>50 keV) has been investigated. The NuSTAR mission, flown on June 2012 a Low Earth Orbit (LEO), provides a unique possibility to confirm the findings of…
In order to fully exploit the physics potential of the ILC, it will be necessary to measure (and control) beam parameters to a permille level precision. In case of the beam polarisation, this can only be achieved with dedicated high energy…
X-ray polarimetry promises to give qualitatively new information about high-energy sources. Examples of interesting source classes are binary black hole systems, rotation and accretion powered neutron stars, Microquasars, Active Galactic…
While the scientific potential of high-energy X-ray and gamma-ray polarimetry has long been recognized, measuring the polarization of high-energy photons is challenging. To date, there has been very few significant detections from an…
An innovative particle detector that offers a compelling combination of cost-effectiveness and high accuracy is introduced. The detector features plastic scintillators paired with a sparse arrangement of SiPMs, strategically positioned…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…