Related papers: High-Resolution Timing for Vertex-Reconstructed Mu…
The usually reported pixel resolution of single pixel imaging (SPI) varies between $32 \times 32$ and $256 \times 256$ pixels falling far below imaging standards with classical methods. Low resolution results from the trade-off between the…
Reliable quantitative analysis in scanning (transmission) electron microscopy (S(T)EM) is often hindered by image drift during long-duration spectral mapping for elemental analysis or for various material functions. We here present…
We present a new method for high-resolution nanoscale magnetic resonance imaging (nano-MRI) that combines the high spin sensitivity of nanowire-based magnetic resonance detection with high spectral resolution nuclear magnetic resonance…
Residual stress is an important factor governing evaluating and controlling the quality of metal materials in industrial products. X-ray measurements provide one of the most effective means of evaluating residual stress without destruction.…
The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A…
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a…
We present optically tunable magnetic 3D metamaterials at terahertz (THz) frequencies which exhibit a tuning range of ~30% of the resonance frequency. This is accomplished by fabricating 3D array structures consisting of double-split-ring…
The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…
Plastic scintillators (PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics, such as in muon taggers,as well as in medical physics and other applications. In this study,a simulation package was built…
The silicon pixel detector (SPD) of the ALICE experiment in preparation at the Large Hadron Collider (LHC) at CERN is designed to provide the precise vertex reconstruction needed for measuring heavy flavor production in heavy ion collisions…
Many years of research and development of High Voltage Monolithic Active Pixel Sensors (HVMAPS) have culminated in the final design for the Mu3e pixel sensor. MuPix10 is a fully monolithic sensor with an active pixel matrix size of…
Significant progress has recently been made in calculating muon stopping sites using density functional theory. The technique aims to address two of the most common criticisms of the muon-spin spectroscopy ($\mu^+$SR) technique, namely,…
This study explores the feasibility of using scintillation detectors for muon calorimetry through experiments conducted at CERN's T10 beamline. Results from organic scintillators with varying thicknesses and readout methods, as well as a…
Multi-pixel fast silicon detectors represent the enabling technology for the next generation of space-borne experiments devoted to high-resolution spectral-timing studies of low-flux compact cosmic sources. Several imaging detectors based…
Resistive AC-coupled Silicon Detectors (RSDs) are based on the Low Gain Avalanche Diode (LGAD) technology, characterized by a continuous gain layer, and by the innovative introduction of resistive read-out. Thanks to a novel electrode…
Silicon carbide detectors exhibit good detection performance such as fast time resolution, high radiation tolerances, high breakdown voltage and low temperature sensitivity and have been studied for detection applications. Meanwhile,…
Photothermal-Induced Resonance (PTIR) is increasingly used in the measurement of infrared absorption spectra of sub-micrometer objects. The technique measures IR absorption spectra by relying on the photothermal effect induced by a rapid…
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche…
For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with…